FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/EHDSMedia

Packagehl7.fhir.eu.imaging-r5
TypeStructureDefinition
IdEHDSMedia
FHIR VersionR5
Sourcehttp://hl7.eu/fhir/imaging-r5/https://build.fhir.org/ig/hl7-eu/imaging/StructureDefinition-EHDSMedia.html
URLhttps://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSMedia
Version0.1.0
Statusdraft
Date2025-03-21T08:17:12+00:00
NameEHDSMedia
TitleMedia model
Realmeu
Authorityhl7
DescriptionC.14 - EHDS refined base model for A photo, video, or audio recording acquired or used in healthcare.
CopyrightUsed by permission of HL7 Europe, all rights reserved Creative Commons License
Typehttps://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSMedia
Kindlogical

Resources that use this resource

ConceptMap
EHDSMediaMapEHDSMedia Mapping
EHDSMediaMapEHDSMedia Mapping
StructureDefinition
EHDSAttachmentsAttachments
EHDSHospitalDischargeReportHospital Discharge Report
EHDSImagingReportImaging report model
EHDSLaboratoryOrderLaboratory order
EHDSLaboratoryReportLaboratory report model
EHDSPatientSummaryPatient summary model
EHDSDischargeReportDischarge Report model
EHDSAttachmentsAttachments
EHDSHospitalDischargeReportHospital Discharge Report
EHDSImagingReportImaging report model
EHDSLaboratoryOrderLaboratory order
EHDSLaboratoryReportLaboratory report model
EHDSPatientSummaryPatient summary model

Resources that this resource uses

StructureDefinition
EHDSAttachmentAttachment model
EHDSDeviceDevice model
EHDSHealthProfessionalHealth professional model
EHDSOrganizationOrganization model
EHDSPatientPatient model
EHDSSpecimenSpecimen model
EHDSAttachmentAttachment model
EHDSDeviceDevice model
EHDSHealthProfessionalHealth professional model
EHDSOrganizationOrganization model
EHDSPatientPatient model
EHDSSpecimenSpecimen model

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: StructureDefinition EHDSMedia

NameFlagsCard.TypeDescription & Constraintsdoco
.. EHDSMedia 0..*BaseMedia model
Instances of this logical model can be the target of a Reference
... identifier 0..*IdentifierC.14.1 - Identifier
... type 0..1CodeableConceptC.14.2 - Type
Binding Description: (preferred): HL7 MediaType
... modality 0..1CodeableConceptC.14.3 - Modality
Binding Description: (preferred): HL7 MediaModality
... view 0..1CodeableConceptC.14.4 - View
Binding Description: (preferred): HL7 MediaCollectionView/Projection
... subject[x] 0..1Reference(Patient model | Specimen model)C.14.5 - Subject
... created[x] 0..1C.14.6 - Created
.... createdDateTimedateTime
.... createdPeriodPeriod
... reason 0..*CodeableConceptC.14.7 - Reason
Binding Description: (preferred): SNOMED CT
... bodysite 0..1CodeableConceptC.14.8 - BodySite
Binding Description: (preferred): SNOMED CT
... deviceName 0..1stringC.14.9 - Device name
... device 0..1Reference(Device model)C.14.10 - Device
... content 1..1EHDSAttachmentC.14.11 - Content
... note 0..*NarrativeC.14.12 - Note
This profile does not constrain the narrative in regard to content, language, or traceability to data elements
... performer 0..*Reference(Health professional model | Organization model)C.14.13 - Performer

doco Documentation for this format

Source

{
  "resourceType": "StructureDefinition",
  "id": "EHDSMedia",
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-type-characteristics",
      "valueCode": "can-be-target"
    }
  ],
  "url": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSMedia",
  "version": "0.1.0",
  "name": "EHDSMedia",
  "title": "Media model",
  "status": "draft",
  "date": "2025-03-21T08:17:12+00:00",
  "publisher": "HL7 Europe",
  "contact": [
    {
      "name": "Xt-EHR",
      "telecom": [
        {
          "system": "url",
          "value": "http://Xt-EHR.eu"
        }
      ]
    }
  ],
  "description": "C.14 - EHDS refined base model for A photo, video, or audio recording acquired or used in healthcare.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "150",
          "display": "Europe"
        }
      ]
    }
  ],
  "copyright": "Used by permission of HL7 Europe, all rights reserved Creative Commons License",
  "fhirVersion": "5.0.0",
  "mapping": [
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    }
  ],
  "kind": "logical",
  "abstract": false,
  "type": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSMedia",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Base",
  "derivation": "specialization",
  "snapshot": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
        "valueString": "5.0.0"
      }
    ],
    "element": [
      {
        "id": "EHDSMedia",
        "path": "EHDSMedia",
        "short": "Media model",
        "definition": "C.14 - EHDS refined base model for A photo, video, or audio recording acquired or used in healthcare.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Base",
          "min": 0,
          "max": "*"
        },
        "isModifier": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "EHDSMedia.identifier",
        "path": "EHDSMedia.identifier",
        "short": "C.14.1 - Identifier",
        "definition": "Image identifier",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSMedia.identifier",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Identifier"
          }
        ]
      },
      {
        "id": "EHDSMedia.type",
        "path": "EHDSMedia.type",
        "short": "C.14.2 - Type",
        "definition": "Classification of media as image, video, audio recording or other media type",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSMedia.type",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "HL7 MediaType"
        }
      },
      {
        "id": "EHDSMedia.modality",
        "path": "EHDSMedia.modality",
        "short": "C.14.3 - Modality",
        "definition": "The type of acquisition equipment/process",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSMedia.modality",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "HL7 MediaModality"
        }
      },
      {
        "id": "EHDSMedia.view",
        "path": "EHDSMedia.view",
        "short": "C.14.4 - View",
        "definition": "The name of the imaging view e.g. Lateral or Antero-posterior",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSMedia.view",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "HL7 MediaCollectionView/Projection"
        }
      },
      {
        "id": "EHDSMedia.subject[x]",
        "path": "EHDSMedia.subject[x]",
        "short": "C.14.5 - Subject",
        "definition": "Who/What this Media is a record of",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSMedia.subject[x]",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSPatient",
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSSpecimen"
            ]
          }
        ]
      },
      {
        "id": "EHDSMedia.created[x]",
        "path": "EHDSMedia.created[x]",
        "short": "C.14.6 - Created",
        "definition": "The date and time(s) at which the media was collected.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSMedia.created[x]",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          },
          {
            "code": "Period"
          }
        ]
      },
      {
        "id": "EHDSMedia.reason",
        "path": "EHDSMedia.reason",
        "short": "C.14.7 - Reason",
        "definition": "Describes why the event occurred in coded or textual form.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSMedia.reason",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "SNOMED CT"
        }
      },
      {
        "id": "EHDSMedia.bodysite",
        "path": "EHDSMedia.bodysite",
        "short": "C.14.8 - BodySite",
        "definition": "Observed body part, i.e. target site",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSMedia.bodysite",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "SNOMED CT"
        }
      },
      {
        "id": "EHDSMedia.deviceName",
        "path": "EHDSMedia.deviceName",
        "short": "C.14.9 - Device name",
        "definition": "The name of the device / manufacturer of the device that was used to make the recording.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSMedia.deviceName",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "EHDSMedia.device",
        "path": "EHDSMedia.device",
        "short": "C.14.10 - Device",
        "definition": "The device used to collect the media.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSMedia.device",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice"
            ]
          }
        ]
      },
      {
        "id": "EHDSMedia.content",
        "path": "EHDSMedia.content",
        "short": "C.14.11 - Content",
        "definition": "The actual content of the media - inline or by direct reference to the media source file.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSMedia.content",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment"
          }
        ]
      },
      {
        "id": "EHDSMedia.note",
        "path": "EHDSMedia.note",
        "short": "C.14.12 - Note",
        "definition": "Comments made about the media by the performer, subject or other participants.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSMedia.note",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Narrative"
          }
        ]
      },
      {
        "id": "EHDSMedia.performer",
        "path": "EHDSMedia.performer",
        "short": "C.14.13 - Performer",
        "definition": "Performer of the imaging acquisition process.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSMedia.performer",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSHealthProfessional",
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSOrganization"
            ]
          }
        ]
      }
    ]
  },
  "differential": {
    "element": [
      {
        "id": "EHDSMedia",
        "path": "EHDSMedia",
        "short": "Media model",
        "definition": "C.14 - EHDS refined base model for A photo, video, or audio recording acquired or used in healthcare."
      },
      {
        "id": "EHDSMedia.identifier",
        "path": "EHDSMedia.identifier",
        "short": "C.14.1 - Identifier",
        "definition": "Image identifier",
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "Identifier"
          }
        ]
      },
      {
        "id": "EHDSMedia.type",
        "path": "EHDSMedia.type",
        "short": "C.14.2 - Type",
        "definition": "Classification of media as image, video, audio recording or other media type",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "HL7 MediaType"
        }
      },
      {
        "id": "EHDSMedia.modality",
        "path": "EHDSMedia.modality",
        "short": "C.14.3 - Modality",
        "definition": "The type of acquisition equipment/process",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "HL7 MediaModality"
        }
      },
      {
        "id": "EHDSMedia.view",
        "path": "EHDSMedia.view",
        "short": "C.14.4 - View",
        "definition": "The name of the imaging view e.g. Lateral or Antero-posterior ",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "HL7 MediaCollectionView/Projection"
        }
      },
      {
        "id": "EHDSMedia.subject[x]",
        "path": "EHDSMedia.subject[x]",
        "short": "C.14.5 - Subject",
        "definition": "Who/What this Media is a record of",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSPatient",
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSSpecimen"
            ]
          }
        ]
      },
      {
        "id": "EHDSMedia.created[x]",
        "path": "EHDSMedia.created[x]",
        "short": "C.14.6 - Created",
        "definition": "The date and time(s) at which the media was collected.",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "dateTime"
          },
          {
            "code": "Period"
          }
        ]
      },
      {
        "id": "EHDSMedia.reason",
        "path": "EHDSMedia.reason",
        "short": "C.14.7 - Reason",
        "definition": "Describes why the event occurred in coded or textual form.",
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "SNOMED CT"
        }
      },
      {
        "id": "EHDSMedia.bodysite",
        "path": "EHDSMedia.bodysite",
        "short": "C.14.8 - BodySite",
        "definition": "Observed body part, i.e. target site",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "SNOMED CT"
        }
      },
      {
        "id": "EHDSMedia.deviceName",
        "path": "EHDSMedia.deviceName",
        "short": "C.14.9 - Device name",
        "definition": "The name of the device / manufacturer of the device that was used to make the recording.",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "EHDSMedia.device",
        "path": "EHDSMedia.device",
        "short": "C.14.10 - Device",
        "definition": "The device used to collect the media.",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSDevice"
            ]
          }
        ]
      },
      {
        "id": "EHDSMedia.content",
        "path": "EHDSMedia.content",
        "short": "C.14.11 - Content",
        "definition": "The actual content of the media - inline or by direct reference to the media source file.",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment"
          }
        ]
      },
      {
        "id": "EHDSMedia.note",
        "path": "EHDSMedia.note",
        "short": "C.14.12 - Note",
        "definition": "Comments made about the media by the performer, subject or other participants.",
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "Narrative"
          }
        ]
      },
      {
        "id": "EHDSMedia.performer",
        "path": "EHDSMedia.performer",
        "short": "C.14.13 - Performer",
        "definition": "Performer of the imaging acquisition process. ",
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSHealthProfessional",
              "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSOrganization"
            ]
          }
        ]
      }
    ]
  }
}