FHIR IG Statistics: StructureDefinition/EHDSImagingReport

Packagehl7.fhir.eu.imaging-r5
TypeStructureDefinition
IdEHDSImagingReport
FHIR VersionR5
Sourcehttp://hl7.eu/fhir/imaging-r5/https://build.fhir.org/ig/hl7-eu/imaging/StructureDefinition-EHDSImagingReport.html
URLhttps://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingReport
Version0.1.0
Statusdraft
Date2025-03-21T08:17:12+00:00
NameEHDSImagingReport
TitleImaging report model
Realmeu
Authorityhl7
DescriptionA - EHDS refined base model for Imaging Result Report
CopyrightUsed by permission of HL7 Europe, all rights reserved Creative Commons License
Typehttps://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingReport
Kindlogical

Resources that use this resource

ConceptMap
EHDSImagingReportMapEHDSImagingReport Mapping
EHDSImagingReportMapEHDSImagingReport Mapping
StructureDefinition
EHDSImagingReportBodyImaging report body model
EHDSImagingReportBodyImaging report body model

Resources that this resource uses

StructureDefinition
EHDSAttachmentAttachment model
EHDSImagingReportBodyImaging report body model
EHDSImagingReportHeaderImaging report header model
EHDSImagingStudyImaging study model
EHDSMediaMedia model
EHDSAttachmentAttachment model
EHDSImagingReportBodyImaging report body model
EHDSImagingReportHeaderImaging report header model
EHDSImagingStudyImaging study model
EHDSMediaMedia model

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: StructureDefinition EHDSImagingReport

NameFlagsCard.TypeDescription & Constraintsdoco
.. EHDSImagingReport 0..*BaseImaging report model
Instances of this logical model can be the target of a Reference
... imagingReportHeader 1..1EHDSImagingReportHeaderA.1 - Imaging Report header
... imagingReportStructuredBody 1..1EHDSImagingReportBodyA.2 - Imaging Report structured body
... presentedForms 0..*EHDSAttachmentA.3 - Presented forms
... imagingReportAttachments[x] 0..*A.4 - Attachment, Media
.... imagingReportAttachmentsEHDSAttachmentEHDSAttachment
.... imagingReportAttachmentsEHDSMediaEHDSMedia
... dicomStudyMetadata 0..*EHDSImagingStudyA.5 - Imaging study

doco Documentation for this format

Source

{
  "resourceType": "StructureDefinition",
  "id": "EHDSImagingReport",
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-type-characteristics",
      "valueCode": "can-be-target"
    }
  ],
  "url": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingReport",
  "version": "0.1.0",
  "name": "EHDSImagingReport",
  "title": "Imaging report model",
  "status": "draft",
  "date": "2025-03-21T08:17:12+00:00",
  "publisher": "HL7 Europe",
  "contact": [
    {
      "name": "Xt-EHR",
      "telecom": [
        {
          "system": "url",
          "value": "http://Xt-EHR.eu"
        }
      ]
    }
  ],
  "description": "A - EHDS refined base model for Imaging Result Report",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "150",
          "display": "Europe"
        }
      ]
    }
  ],
  "copyright": "Used by permission of HL7 Europe, all rights reserved Creative Commons License",
  "fhirVersion": "5.0.0",
  "mapping": [
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    }
  ],
  "kind": "logical",
  "abstract": false,
  "type": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingReport",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Base",
  "derivation": "specialization",
  "snapshot": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
        "valueString": "5.0.0"
      }
    ],
    "element": [
      {
        "id": "EHDSImagingReport",
        "path": "EHDSImagingReport",
        "short": "Imaging report model",
        "definition": "A - EHDS refined base model for Imaging Result Report",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Base",
          "min": 0,
          "max": "*"
        },
        "isModifier": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.imagingReportHeader",
        "path": "EHDSImagingReport.imagingReportHeader",
        "short": "A.1 - Imaging Report header",
        "definition": "Report header data elements",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSImagingReport.imagingReportHeader",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingReportHeader"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.imagingReportStructuredBody",
        "path": "EHDSImagingReport.imagingReportStructuredBody",
        "short": "A.2 - Imaging Report structured body",
        "definition": "Report body data elements",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSImagingReport.imagingReportStructuredBody",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingReportBody"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.presentedForms",
        "path": "EHDSImagingReport.presentedForms",
        "short": "A.3 - Presented forms",
        "definition": "Entire report as issued. Various formats could be provided,  pdf format is recommended.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSImagingReport.presentedForms",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.imagingReportAttachments[x]",
        "path": "EHDSImagingReport.imagingReportAttachments[x]",
        "short": "A.4 - Attachment, Media",
        "definition": "Report attachments data elements",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSImagingReport.imagingReportAttachments[x]",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment"
          },
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSMedia"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.dicomStudyMetadata",
        "path": "EHDSImagingReport.dicomStudyMetadata",
        "short": "A.5 - Imaging study",
        "definition": "Metadata of the DICOM study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSImagingReport.dicomStudyMetadata",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingStudy"
          }
        ]
      }
    ]
  },
  "differential": {
    "element": [
      {
        "id": "EHDSImagingReport",
        "path": "EHDSImagingReport",
        "short": "Imaging report model",
        "definition": "A - EHDS refined base model for Imaging Result Report"
      },
      {
        "id": "EHDSImagingReport.imagingReportHeader",
        "path": "EHDSImagingReport.imagingReportHeader",
        "short": "A.1 - Imaging Report header",
        "definition": "Report header data elements",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingReportHeader"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.imagingReportStructuredBody",
        "path": "EHDSImagingReport.imagingReportStructuredBody",
        "short": "A.2 - Imaging Report structured body",
        "definition": "Report body data elements",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSImagingReportBody"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.presentedForms",
        "path": "EHDSImagingReport.presentedForms",
        "short": "A.3 - Presented forms",
        "definition": "Entire report as issued. Various formats could be provided,  pdf format is recommended.",
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.imagingReportAttachments[x]",
        "path": "EHDSImagingReport.imagingReportAttachments[x]",
        "short": "A.4 - Attachment, Media",
        "definition": "Report attachments data elements",
        "min": 0,
        "max": "*",
        "type": [
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSAttachment"
          },
          {
            "code": "https://www.xt-ehr.eu/specifications/fhir/StructureDefinition/EHDSMedia"
          }
        ]
      },
      {
        "id": "EHDSImagingReport.dicomStudyMetadata",
        "path": "EHDSImagingReport.dicomStudyMetadata",
        "short": "A.5 - Imaging study",
        "definition": "Metadata of the DICOM study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.",
        "min": 0,
        "max": "*",
        "type": [
          {