FHIR IG Statistics: StructureDefinition/mii-pr-mtb-immunohistochemistry
Resources that use this resource
Resources that this resource uses
Narrative
No narrative content found in resource
Source
{
"resourceType": "StructureDefinition",
"id": "mii-pr-mtb-immunohistochemistry",
"url": "https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-pr-mtb-immunohistochemistry",
"version": "2024.0.0-ballot",
"name": "MII_PR_MTB_Immunohistochemistry",
"title": "MII PR MTB Immunohistochemistry",
"status": "draft",
"publisher": "Medizininformatik Initiative",
"contact": [
{
"telecom": [
{
"system": "url",
"value": "https://www.medizininformatik-initiative.de"
}
]
}
],
"description": "Immunhistorchemistry report",
"fhirVersion": "4.0.1",
"kind": "resource",
"abstract": false,
"type": "Observation",
"baseDefinition": "https://www.medizininformatik-initiative.de/fhir/ext/modul-mtb/StructureDefinition/mii-pr-mtb-molekularer-biomarker",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "Observation.identifier",
"path": "Observation.identifier",
"mustSupport": true
},
{
"id": "Observation.code",
"path": "Observation.code",
"short": "Code für Immunhistochemische Untersuchung",
"definition": "Kodierung für Immunhistochemische Untersuchung. Nach Möglichkeit sind spezifische Codes zu verwenden. Wenn weder in SNOMED noch LOINC spezifische Codes vorhanden sind, ist über gene-studied ",
"mustSupport": true
},
{
"id": "Observation.code.coding",
"path": "Observation.code.coding",
"slicing": {
"discriminator": [
{
"type": "value",
"path": "code"
}
],
"rules": "open"
},
"mustSupport": true
},
{
"id": "Observation.code.coding:spezifisch",
"path": "Observation.code.coding",
"sliceName": "spezifisch",
"short": "Immunhistochemische Untersuchung",
"definition": "Spezifischer Code SNOMED-CT- oder LOINC-Code für immunhistochemische Untersuchung. Wenn kein spezifischer Code in SNOMED oder LOINC vorhanden ist, ist der generische Code zu verwenden und das nachgewiesene Gen unter component[gene-studied] anzugeben.",
"min": 0,
"max": "1",
"mustSupport": true
},
{
"id": "Observation.code.coding:spezifisch.system",
"path": "Observation.code.coding.system",
"min": 1,
"mustSupport": true
},
{
"id": "Observation.code.coding:generisch",
"path": "Observation.code.coding",
"sliceName": "generisch",
"short": "Generische Immunhistochemischer Untersuchungscode. Nur zu benutzen, wenn kein spezifischer Code in SNOMED oder LOINC vorhanden ist. ",
"min": 0,
"max": "1",
"patternCoding": {
"code": "1234806008",
"system": "http://snomed.info/sct",
"display": "Observation using immunohistochemistry (observable entity)"
},
"mustSupport": true
},
{
"id": "Observation.value[x]",
"path": "Observation.value[x]",
"slicing": {
"discriminator": [
{
"type": "type",
"path": "$this"
}
],
"ordered": false,
"rules": "open"
},
"mustSupport": true
},
{
"id": "Observation.value[x]:valueCodeableConcept",
"path": "Observation.value[x]",
"sliceName": "valueCodeableConcept",
"short": "Ergebnis der für immunhistochemische Untersuchung",
"definition": "Ergebnis der immunhistochemischen Untersuchung.",
"min": 0,
"max": "1",
"type": [
{
"code": "CodeableConcept"
}
],
"mustSupport": true
},
{
"id": "Observation.interpretation",
"path": "Observation.interpretation",
"mustSupport": true
},
{
"id": "Observation.specimen",
"path": "Observation.specimen",
"short": "Block / Material-Nr. der Probe",
"definition": "Block-MAterial-Nr. der Probe. Da jede FHIR-Observation nur eine Referenz auf Specimen haben kann, Die gesamte Probe (z.B. Biopsie, Exzisat) wird von den Einzelschnitten referenziert. ",
"mustSupport": true
},
{
"id": "Observation.component:gene-studied",
"path": "Observation.component",
"sliceName": "gene-studied",
"max": "1",
"mustSupport": true
}
]
}
}