FHIR IG analytics

Packagede.gematik.hddt
Resource TypeStructureDefinition
IdStructureDefinition-hddt-lung-function-testing-complete.json
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=de.gematik.hddt@1.0.0-rc&canonical=https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-function-testing-complete
URLhttps://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-function-testing-complete
Version1.0.0-rc
Statusactive
Date2026-01-16
NameHddtLungFunctionTestingComplete
TitleObservation – Complete Lung Function Testing
DescriptionProfile for capturing the relative lung function testings (i.e. an individual measurement divided by the corresponding reference value) as FHIR Observation resources. This profile defines the exchange of a single relative value for the Mandatory Interoperable Value (MIV) \"Lung Function Testing\" which is technically defined by the ValueSet _hddt-miv-lung-function-testing_. This MIV is e.g. implemented by peak flow meter that can connect to a Personal Health Gateway (e.g. a mobile app for tracking lung function values) through wireless or wired communication. **Obligations and Conventions:** Each Lung Function Testing MAY either hold a reference to a _Sensor Type And Calibration Status_ [DeviceMetric](https://hl7.org/fhir/R4/devicemetric.html) resource or to a _Personal Health Device_ [Device](https://hl7.org/fhir/R4/device.html) resource (eXclusive OR). Typically the reference will be to a [Device](https://hl7.org/fhir/R4/device.html) resource, but the option to reference a [DeviceMetric](https://hl7.org/fhir/R4/devicemetric.html) resource is provided for compatibility with the overarching HDDT specification. Each instance of this Observation MUST reference the Observations holding the corresponding raw measurement and reference value via the `derivedFrom` element. **Constraints applied:** - `status` is restricted to _final_ - `code` is constrained to a subset of the _MIV Lung Function Relative Values_ ValueSet, defined by the _HddtLungFunctionRelativeValues_ ValueSet. - `effective[x]` is restricted to `effectiveDateTime` and constrained as mandatory. - `value[x]` is restricted to `valueQuantity`. The elements `valueQuantity.value`, `valueQuantity.system`, and `valueQuantity.code` are constrained in a way that a value MUST be provided and that UCUM MUST be used for encoding the unit of measurement. `Observation.valueQuantity` MAY only be omitted in case of an error that accured with the measurement. In this case, `Observation.dataAbsentReason` MUST be provided. - `derivedFrom` is constrained to require exactly two references: one to the raw lung function testing Observation and one to the lung function reference value Observation.
CopyrightCopyright (c) 2026 gematik GmbH
TypeObservation
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
hddt-lung-function-testingObservation – Lung Function Testing
hddt-lung-reference-valueObservation – Lung Function Reference Value
hddt-personal-health-deviceDevice – Personal Health Device
hddt-sensor-type-and-calibration-statusDeviceMetric – Sensor Type and Calibration Status
ValueSet
hddt-lung-function-relative-valuesLung Function Relative Values from LOINC

Narrative

No narrative content found in resource


Source1

{
  "resourceType": "StructureDefinition",
  "id": "hddt-lung-function-testing-complete",
  "url": "https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-function-testing-complete",
  "version": "1.0.0-rc",
  "name": "HddtLungFunctionTestingComplete",
  "title": "Observation – Complete Lung Function Testing",
  "status": "active",
  "date": "2026-01-16",
  "publisher": "gematik GmbH",
  "description": "Profile for capturing the relative lung function testings (i.e. an individual measurement divided by the corresponding reference value) \nas FHIR Observation resources.\n\nThis profile defines the exchange of a single relative value for the Mandatory Interoperable Value (MIV) \\\"Lung Function Testing\\\" which is technically defined \nby the ValueSet _hddt-miv-lung-function-testing_. This MIV is e.g. implemented by peak flow meter that can connect to \na Personal Health Gateway (e.g. a mobile app for tracking lung function values) through wireless or wired communication.\n\n**Obligations and Conventions:**\n\nEach Lung Function Testing MAY either hold a reference to a _Sensor Type And Calibration Status_ [DeviceMetric](https://hl7.org/fhir/R4/devicemetric.html) resource or to a \n_Personal Health Device_ [Device](https://hl7.org/fhir/R4/device.html) resource (eXclusive OR). Typically the reference will be \nto a [Device](https://hl7.org/fhir/R4/device.html) resource, but the option to reference a [DeviceMetric](https://hl7.org/fhir/R4/devicemetric.html) \nresource is provided for compatibility with the overarching HDDT specification.\n\nEach instance of this Observation MUST reference the Observations holding the corresponding raw measurement and reference value via the `derivedFrom` element.\n\n**Constraints applied:**  \n- `status` is restricted to _final_\n- `code` is constrained to a subset of the _MIV Lung Function Relative Values_ ValueSet, defined by the _HddtLungFunctionRelativeValues_ ValueSet.\n- `effective[x]` is restricted to `effectiveDateTime` and constrained as mandatory.\n- `value[x]` is restricted to `valueQuantity`. The elements `valueQuantity.value`, `valueQuantity.system`, and `valueQuantity.code` are constrained in a way that a value MUST be provided and that UCUM MUST be used for encoding the unit of measurement. `Observation.valueQuantity` MAY only be omitted in case of an error that accured with the measurement. In this case, `Observation.dataAbsentReason` MUST be provided.\n- `derivedFrom` is constrained to require exactly two references: one to the raw lung function testing Observation and one to the lung function reference value Observation.",
  "copyright": "Copyright (c) 2026 gematik GmbH",
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Observation",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation.status",
        "path": "Observation.status",
        "short": "Measurement status",
        "definition": "The status of the measurements is fixed to 'final'. Only verified and complete measurements with a valid value are represented.",
        "fixedCode": "final"
      },
      {
        "id": "Observation.code",
        "path": "Observation.code",
        "short": "Percentage measurement type for lung function",
        "binding": {
          "strength": "required",
          "valueSet": "https://gematik.de/fhir/hddt/ValueSet/hddt-lung-function-relative-values",
          "description": "Specifies the type of measurement using codes from the ValueSet for lung function testing as percentage of the reference value. Constrained via invariant to either PEF or FEV1."
        }
      },
      {
        "id": "Observation.effective[x]",
        "path": "Observation.effective[x]",
        "short": "Time of measurement",
        "definition": "The time when the lung function testing was taken.",
        "min": 1,
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "Observation.value[x]",
        "path": "Observation.value[x]",
        "short": "Calculated lung function value as percentage of reference value",
        "definition": "The lung function value represented as percentage of the reference value",
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true
      },
      {
        "id": "Observation.value[x].value",
        "path": "Observation.value[x].value",
        "min": 1
      },
      {
        "id": "Observation.value[x].system",
        "path": "Observation.value[x].system",
        "min": 1,
        "fixedUri": "http://unitsofmeasure.org"
      },
      {
        "id": "Observation.value[x].code",
        "path": "Observation.value[x].code",
        "definition": "The UCUM code representing the unit of the lung function testing. The UCUM code MUST be compliant with the example unit that is linked with the LOINC code given as `Observation.code`.",
        "min": 1,
        "binding": {
          "strength": "required",
          "valueSet": "http://hl7.org/fhir/ValueSet/ucum-units",
          "description": "Defines the unit of measurement using codes from the UCUM units ValueSet. The UCUM code MUST be compliant with the unit that is linked with the LOINC code given as `Observation.code`."
        }
      },
      {
        "id": "Observation.device",
        "path": "Observation.device",
        "short": "Reference to personal health device",
        "definition": "References a Device resource that describes the personal health device.",
        "min": 1,
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://gematik.de/fhir/hddt/StructureDefinition/hddt-personal-health-device",
              "https://gematik.de/fhir/hddt/StructureDefinition/hddt-sensor-type-and-calibration-status"
            ]
          }
        ]
      },
      {
        "id": "Observation.derivedFrom",
        "path": "Observation.derivedFrom",
        "slicing": {
          "discriminator": [
            {
              "type": "profile",
              "path": "resolve()"
            }
          ],
          "rules": "closed",
          "description": "Slice to require one reference to a measurement and one to a reference value"
        },
        "min": 2,
        "max": "2"
      },
      {
        "id": "Observation.derivedFrom:measurement",
        "path": "Observation.derivedFrom",
        "sliceName": "measurement",
        "short": "Reference to raw lung function testing",
        "definition": "Reference to the lung function testing Observation that holds the actual measured value.",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-function-testing"
            ]
          }
        ]
      },
      {
        "id": "Observation.derivedFrom:referenceValue",
        "path": "Observation.derivedFrom",
        "sliceName": "referenceValue",
        "short": "Reference to lung function reference value",
        "definition": "Reference to the Observation holding the reference range and information about the reference range determination method.",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-reference-value"
            ]
          }
        ]
      }
    ]
  }
}