| Package | de.gematik.hddt |
| Resource Type | StructureDefinition |
| Id | StructureDefinition-hddt-lung-function-testing-complete.json |
| FHIR Version | R4 |
| Source | https://simplifier.net/resolve?scope=de.gematik.hddt@1.0.0-rc&canonical=https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-function-testing-complete |
| URL | https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-function-testing-complete |
| Version | 1.0.0-rc |
| Status | active |
| Date | 2026-01-16 |
| Name | HddtLungFunctionTestingComplete |
| Title | Observation – Complete Lung Function Testing |
| Description | Profile for capturing the relative lung function testings (i.e. an individual measurement divided by the corresponding reference value)
as FHIR Observation resources.
This profile defines the exchange of a single relative value for the Mandatory Interoperable Value (MIV) \"Lung Function Testing\" which is technically defined
by the ValueSet _hddt-miv-lung-function-testing_. This MIV is e.g. implemented by peak flow meter that can connect to
a Personal Health Gateway (e.g. a mobile app for tracking lung function values) through wireless or wired communication.
**Obligations and Conventions:**
Each Lung Function Testing MAY either hold a reference to a _Sensor Type And Calibration Status_ [DeviceMetric](https://hl7.org/fhir/R4/devicemetric.html) resource or to a
_Personal Health Device_ [Device](https://hl7.org/fhir/R4/device.html) resource (eXclusive OR). Typically the reference will be
to a [Device](https://hl7.org/fhir/R4/device.html) resource, but the option to reference a [DeviceMetric](https://hl7.org/fhir/R4/devicemetric.html)
resource is provided for compatibility with the overarching HDDT specification.
Each instance of this Observation MUST reference the Observations holding the corresponding raw measurement and reference value via the `derivedFrom` element.
**Constraints applied:**
- `status` is restricted to _final_
- `code` is constrained to a subset of the _MIV Lung Function Relative Values_ ValueSet, defined by the _HddtLungFunctionRelativeValues_ ValueSet.
- `effective[x]` is restricted to `effectiveDateTime` and constrained as mandatory.
- `value[x]` is restricted to `valueQuantity`. The elements `valueQuantity.value`, `valueQuantity.system`, and `valueQuantity.code` are constrained in a way that a value MUST be provided and that UCUM MUST be used for encoding the unit of measurement. `Observation.valueQuantity` MAY only be omitted in case of an error that accured with the measurement. In this case, `Observation.dataAbsentReason` MUST be provided.
- `derivedFrom` is constrained to require exactly two references: one to the raw lung function testing Observation and one to the lung function reference value Observation. |
| Copyright | Copyright (c) 2026 gematik GmbH |
| Type | Observation |
| Kind | resource |
Resources that use this resource
No resources found
Resources that this resource uses
Narrative
No narrative content found in resource
Source1
{
"resourceType": "StructureDefinition",
"id": "hddt-lung-function-testing-complete",
"url": "https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-function-testing-complete",
"version": "1.0.0-rc",
"name": "HddtLungFunctionTestingComplete",
"title": "Observation – Complete Lung Function Testing",
"status": "active",
"date": "2026-01-16",
"publisher": "gematik GmbH",
"description": "Profile for capturing the relative lung function testings (i.e. an individual measurement divided by the corresponding reference value) \nas FHIR Observation resources.\n\nThis profile defines the exchange of a single relative value for the Mandatory Interoperable Value (MIV) \\\"Lung Function Testing\\\" which is technically defined \nby the ValueSet _hddt-miv-lung-function-testing_. This MIV is e.g. implemented by peak flow meter that can connect to \na Personal Health Gateway (e.g. a mobile app for tracking lung function values) through wireless or wired communication.\n\n**Obligations and Conventions:**\n\nEach Lung Function Testing MAY either hold a reference to a _Sensor Type And Calibration Status_ [DeviceMetric](https://hl7.org/fhir/R4/devicemetric.html) resource or to a \n_Personal Health Device_ [Device](https://hl7.org/fhir/R4/device.html) resource (eXclusive OR). Typically the reference will be \nto a [Device](https://hl7.org/fhir/R4/device.html) resource, but the option to reference a [DeviceMetric](https://hl7.org/fhir/R4/devicemetric.html) \nresource is provided for compatibility with the overarching HDDT specification.\n\nEach instance of this Observation MUST reference the Observations holding the corresponding raw measurement and reference value via the `derivedFrom` element.\n\n**Constraints applied:** \n- `status` is restricted to _final_\n- `code` is constrained to a subset of the _MIV Lung Function Relative Values_ ValueSet, defined by the _HddtLungFunctionRelativeValues_ ValueSet.\n- `effective[x]` is restricted to `effectiveDateTime` and constrained as mandatory.\n- `value[x]` is restricted to `valueQuantity`. The elements `valueQuantity.value`, `valueQuantity.system`, and `valueQuantity.code` are constrained in a way that a value MUST be provided and that UCUM MUST be used for encoding the unit of measurement. `Observation.valueQuantity` MAY only be omitted in case of an error that accured with the measurement. In this case, `Observation.dataAbsentReason` MUST be provided.\n- `derivedFrom` is constrained to require exactly two references: one to the raw lung function testing Observation and one to the lung function reference value Observation.",
"copyright": "Copyright (c) 2026 gematik GmbH",
"fhirVersion": "4.0.1",
"kind": "resource",
"abstract": false,
"type": "Observation",
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/Observation",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "Observation.status",
"path": "Observation.status",
"short": "Measurement status",
"definition": "The status of the measurements is fixed to 'final'. Only verified and complete measurements with a valid value are represented.",
"fixedCode": "final"
},
{
"id": "Observation.code",
"path": "Observation.code",
"short": "Percentage measurement type for lung function",
"binding": {
"strength": "required",
"valueSet": "https://gematik.de/fhir/hddt/ValueSet/hddt-lung-function-relative-values",
"description": "Specifies the type of measurement using codes from the ValueSet for lung function testing as percentage of the reference value. Constrained via invariant to either PEF or FEV1."
}
},
{
"id": "Observation.effective[x]",
"path": "Observation.effective[x]",
"short": "Time of measurement",
"definition": "The time when the lung function testing was taken.",
"min": 1,
"type": [
{
"code": "dateTime"
}
]
},
{
"id": "Observation.value[x]",
"path": "Observation.value[x]",
"short": "Calculated lung function value as percentage of reference value",
"definition": "The lung function value represented as percentage of the reference value",
"type": [
{
"code": "Quantity"
}
],
"mustSupport": true
},
{
"id": "Observation.value[x].value",
"path": "Observation.value[x].value",
"min": 1
},
{
"id": "Observation.value[x].system",
"path": "Observation.value[x].system",
"min": 1,
"fixedUri": "http://unitsofmeasure.org"
},
{
"id": "Observation.value[x].code",
"path": "Observation.value[x].code",
"definition": "The UCUM code representing the unit of the lung function testing. The UCUM code MUST be compliant with the example unit that is linked with the LOINC code given as `Observation.code`.",
"min": 1,
"binding": {
"strength": "required",
"valueSet": "http://hl7.org/fhir/ValueSet/ucum-units",
"description": "Defines the unit of measurement using codes from the UCUM units ValueSet. The UCUM code MUST be compliant with the unit that is linked with the LOINC code given as `Observation.code`."
}
},
{
"id": "Observation.device",
"path": "Observation.device",
"short": "Reference to personal health device",
"definition": "References a Device resource that describes the personal health device.",
"min": 1,
"type": [
{
"code": "Reference",
"targetProfile": [
"https://gematik.de/fhir/hddt/StructureDefinition/hddt-personal-health-device",
"https://gematik.de/fhir/hddt/StructureDefinition/hddt-sensor-type-and-calibration-status"
]
}
]
},
{
"id": "Observation.derivedFrom",
"path": "Observation.derivedFrom",
"slicing": {
"discriminator": [
{
"type": "profile",
"path": "resolve()"
}
],
"rules": "closed",
"description": "Slice to require one reference to a measurement and one to a reference value"
},
"min": 2,
"max": "2"
},
{
"id": "Observation.derivedFrom:measurement",
"path": "Observation.derivedFrom",
"sliceName": "measurement",
"short": "Reference to raw lung function testing",
"definition": "Reference to the lung function testing Observation that holds the actual measured value.",
"min": 1,
"max": "1",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-function-testing"
]
}
]
},
{
"id": "Observation.derivedFrom:referenceValue",
"path": "Observation.derivedFrom",
"sliceName": "referenceValue",
"short": "Reference to lung function reference value",
"definition": "Reference to the Observation holding the reference range and information about the reference range determination method.",
"min": 1,
"max": "1",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://gematik.de/fhir/hddt/StructureDefinition/hddt-lung-reference-value"
]
}
]
}
]
}
}