FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagextehr.eu.ehds.models
Resource TypeStructureDefinition
IdStructureDefinition-EHDSLaboratoryReportObligations.json
FHIR VersionR5
Sourcehttps://build.fhir.org/ig/Xt-EHR/xt-ehr-common/StructureDefinition-EHDSLaboratoryReportObligations.html
URLhttp://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations
Version0.4.0
Statusdraft
Date2026-03-25T12:28:36+00:00
NameEHDSLaboratoryReportObligations
TitleLaboratory Report Obligations
DescriptionObligations for the logical model of laboratory report
Typehttp://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReport
Kindlogical

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
xtehr.eu.ehds.models#currentEHDSLaboratoryReportLaboratory report model

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: StructureDefinition EHDSLaboratoryReportObligations

Language: en

NameFlagsCard.TypeDescription & Constraintsdoco
.. EHDSLaboratoryReport 0..*EHDSLaboratoryReportLaboratory report model
Instances of this logical model can be the target of a Reference
... header O1..1BaseLaboratory Report header
ObligationsActor
SHALL:able-to-populateProducer
SHALL:processConsumer
.... subject O1..1EHDSPatientPatient/subject information
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
SHALL:processConsumer
.... identifier O1..*IdentifierUnique identifier of the document
ObligationsActor
SHALL:able-to-populateProducer
SHOULD:displayConsumer
SHALL:processConsumer
.... author[x] O1..*EHDSHealthProfessional, EHDSOrganisation, EHDSDeviceAuthor(s) by whom the laboratory result report was authored.
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
.... date O1..1dateTimeDate of finalising/issuing the document
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
.... status O1..1CodeableConceptStatus of the document
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
.... language O0..1CodeableConceptLanguage in which the resource is written. Language is expressed by the IETF language tag.
ObligationsActor
SHALL:able-to-populateProducer
.... documentType O1..1CodeableConceptType of document at hand, e.g. 60591-5 Patient summary document.
ObligationsActor
SHALL:able-to-populateProducer
.... documentTitle O1..1stringHuman readable document title that can be displayed in search results, etc. This can be documentType's display name, or it can be assembled from multiple elements. Examples: 'Laboratory Result Report', 'Patient Summary of Jane Green 10.12.2024'
ObligationsActor
SHALL:able-to-populateProducer
.... period O0..1PeriodTime of service that is being documented
ObligationsActor
SHALL:able-to-populateProducer
.... attestation O0..*BaseDocument attestation details
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... attester[x] O1..1EHDSHealthProfessional, EHDSDeviceAttester who validated the document
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... datetime O1..1dateTimeDate and time of the approval of the document by Attester
ObligationsActor
SHALL:able-to-populateProducer
.... legalAuthentication O0..*BaseDocument legal authentication details
ObligationsActor
SHALL:able-to-populateProducer
..... legalAuthenticator[x] O1..1EHDSHealthProfessional, EHDSOrganisationThe person or organisation taking responsibility for the content of the document.
ObligationsActor
SHALL:able-to-populateProducer
..... datetime O1..1dateTimeDate and time when the document was authorised
ObligationsActor
SHALL:able-to-populateProducer
.... eventType O0..*CodeableConceptCategorisation of the event covered by the document (e.g. laboratory study types, imaging study types including modality, etc.). Selection of such tags or labels depends on the use case and agreement between data sharing parties. This meta-data element serves primarily for searching and filtering purposes.
ObligationsActor
SHALL:able-to-populateProducer
.... serviceSpecialty O0..*CodeableConceptAdditional details about where the content was created (e.g. clinical specialty)
ObligationsActor
SHALL:able-to-populateProducer
SHOULD:displayConsumer
.... custodian O0..1EHDSOrganisationOrganisation that is in charge of maintaining the document/report.
ObligationsActor
SHALL:able-to-populateProducer
... presentedForm O0..*EHDSAttachmentA narrative easy-to-read representation of the full data set, e.g. PDF-version of a document
ObligationsActor
SHALL:able-to-populateProducer
SHALL:processConsumer
SHALL:displayConsumer
... body O0..1BaseLaboratory Report structured body
ObligationsActor
SHALL:able-to-populateProducer
SHALL:processConsumer
.... orderInformation O0..*BaseOrder Information (Laboratory Result Report could respond to multiple test orders)
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... orderId O1..*IdentifierAn identifier of the laboratory test order. Laboratory Result Report may respond to multiple orders.
ObligationsActor
SHALL:able-to-populateProducer
SHOULD:processConsumer
..... orderPlacer[x] O0..1EHDSHealthProfessional, EHDSOrganisation, EHDSPatientThe person/organisation "authorised" to place the order. Order placer could be either a health professional, health professional organisation or the patient himself.
ObligationsActor
SHALL:able-to-populateProducer
SHOULD:displayConsumer
..... orderReason[x] O0..*CodeableConcept, EHDSCondition, EHDSObservation, stringAn explanation or justification for why this service is being requested in coded form.
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... clinicalQuestion O0..1stringSpecification of clinical question (goal of the investigation) to be answered by the laboratory investigation.
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
.... supportingInformation O0..1BaseAdditional clinical information about the patient or specimen that may influence the services or their interpretations. This information includes diagnosis, clinical findings and other observations. In laboratory ordering these are typically referred to as 'ask at order entry questions (AOEs).' This includes observations explicitly requested by the producer (filler) to provide context or supporting information needed to complete the order. For example, reporting the amount of inspired oxygen for blood gas measurements.
ObligationsActor
SHOULD:able-to-populateProducer
SHALL:displayConsumer
..... observation O0..*EHDSObservationClinical findings and other observations.
ObligationsActor
SHOULD:able-to-populateProducer
SHALL:displayConsumer
..... condition O0..*EHDSConditionCondition that may influence the service or result interpretation.
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... medicationAdministration O0..*EHDSMedicationAdministrationMedication administered before ordering the service.
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... sexForClinicalUse O0..1CodeableConceptA Sex Parameter for Clinical Use is a parameter that provides guidance on how a recipient should apply settings or reference ranges that are derived from observable information such as an organ inventory, recent hormone lab tests, genetic testing, menstrual status, obstetric history, etc.. This property is intended for use in clinical decision making, and indicates that treatment or diagnostic tests should consider best practices associated with the relevant reference population
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... vaccination O0..*EHDSImmunisationVaccination history of the patient.
ObligationsActor
SHOULD:able-to-populateProducer
SHALL:displayConsumer
..... otherSupportingInformation O0..*ResourceAny other type of relevant supporting information
ObligationsActor
SHOULD:able-to-populateProducer
SHOULD:displayConsumer
.... specimen O0..*EHDSSpecimenSpecimen information
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
.... serviceRequest O0..*EHDSServiceRequestSpecification of requested service or services
ObligationsActor
SHALL:able-to-populateProducer
SHOULD:displayConsumer
.... resultData O1..1BaseLaboratory report result data
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... commentsInterpretationAndRecommendations O0..*NarrativeNarrative Comments, such as a textual interpretation or advice accompanying the result report, for example.
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
..... laboratoryTestResults O0..*EHDSLaboratoryObservationObservation details (report could consist of multiple observations)
ObligationsActor
SHALL:able-to-populateProducer
SHALL:displayConsumer
... attachments O0..*EHDSAttachmentReport attachments
ObligationsActor
SHOULD:able-to-populateProducer
SHOULD:processConsumer
SHOULD:displayConsumer

doco Documentation for this format

Source1

{
  "resourceType": "StructureDefinition",
  "id": "EHDSLaboratoryReportObligations",
  "language": "en",
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-type-characteristics",
      "valueCode": "can-be-target"
    }
  ],
  "url": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations",
  "version": "0.4.0",
  "name": "EHDSLaboratoryReportObligations",
  "title": "Laboratory Report Obligations",
  "status": "draft",
  "date": "2026-03-25T12:28:36+00:00",
  "publisher": "Xt-EHR",
  "contact": [
    {
      "name": "Xt-EHR",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.xt-ehr.eu/"
        }
      ]
    }
  ],
  "description": "Obligations for the logical model of laboratory report",
  "fhirVersion": "5.0.0",
  "mapping": [
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    }
  ],
  "kind": "logical",
  "abstract": false,
  "type": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReport",
  "baseDefinition": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReport",
  "derivation": "constraint",
  "snapshot": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
        "valueString": "0.4.0"
      }
    ],
    "element": [
      {
        "id": "EHDSLaboratoryReport",
        "path": "EHDSLaboratoryReport",
        "short": "Laboratory report model",
        "definition": "Laboratory result report model.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Base",
          "min": 0,
          "max": "*"
        },
        "isModifier": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Each producer of a laboratory report SHALL be able to provide basic information, such as type of the report, authorship, status of the report, title, etc. This information is crucial for safe identification of the report and for searchability of the report using standardized searching parameters."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHALL process document header information."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header",
        "short": "Laboratory Report header",
        "definition": "Basic metadata for this information",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDataSet.header",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.subject",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems SHALL provide information about the subject of care."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR system SHALL render information about the subject of care in such a way that unambiguous assignment to the care subject is preserved."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Information about the subject of care SHALL be processed by the EHR system in such a way that the identity of the subject of care cannot be confused."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.subject",
        "short": "Patient/subject information",
        "definition": "Patient/subject information",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDataSet.header.subject",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSPatient"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.identifier",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.identifier",
        "short": "Unique identifier of the document",
        "definition": "Business identifier for the object, unique within its system. Supporting disambiguation between different contexts (systems/countries).",
        "min": 1,
        "max": "*",
        "base": {
          "path": "EHDSDataSet.header.identifier",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Identifier"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.author[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.author[x]",
        "short": "Author(s) by whom the laboratory result report was authored.",
        "definition": "Author(s) by whom the laboratory result report was authored. Multiple authors could be provided.",
        "comment": "Author of the laboratory report could be either a health professional who authored the report, laboratory itself or laboratory information system. Author information is the only mandatory element of the laboratory report header. As such, each laboratory shall be able to provide at least the author information.",
        "min": 1,
        "max": "*",
        "base": {
          "path": "EHDSDataSet.header.author[x]",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSHealthProfessional"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSOrganisation"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDevice"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.date",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.date",
        "short": "Date of finalising/issuing the document",
        "definition": "Date and optionally time of authoring/issuing",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDataSet.header.date",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.status",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.status",
        "short": "Status of the document",
        "definition": "Status of the resource or document",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDataSet.header.status",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.source",
        "path": "EHDSLaboratoryReport.header.source",
        "short": "Source of information (e.g. patient, patient's proxy). Used in case the patient has authored the information or the author has submitted patient-stated information.",
        "definition": "Source of information (e.g. patient, patient's proxy). Used in case the patient has authored the information or the author has submitted patient-stated information.",
        "min": 0,
        "max": "0",
        "base": {
          "path": "EHDSDataSet.header.source",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.language",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.language",
        "short": "Language in which the resource is written. Language is expressed by the IETF language tag.",
        "definition": "Language in which the resource is written. Language is expressed by the IETF language tag.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSDataSet.header.language",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "BCP 47"
        }
      },
      {
        "id": "EHDSLaboratoryReport.header.documentType",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.documentType",
        "short": "Type of document at hand, e.g. 60591-5 Patient summary document.",
        "definition": "Type of document at hand, e.g. 60591-5 Patient summary document.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.documentType",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "LOINC"
        }
      },
      {
        "id": "EHDSLaboratoryReport.header.documentTitle",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.documentTitle",
        "short": "Human readable document title that can be displayed in search results, etc. This can be documentType's display name, or it can be assembled from multiple elements. Examples: 'Laboratory Result Report', 'Patient Summary of Jane Green 10.12.2024'",
        "definition": "Human readable document title that can be displayed in search results, etc. This can be documentType's display name, or it can be assembled from multiple elements. Examples: 'Laboratory Result Report', 'Patient Summary of Jane Green 10.12.2024'",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.documentTitle",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.period",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.period",
        "short": "Time of service that is being documented",
        "definition": "Time of service that is being documented",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.period",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Period"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.version",
        "path": "EHDSLaboratoryReport.header.version",
        "short": "Business version of the document. The exact algorithm for versioning is decided by the producer/custodian",
        "definition": "Business version of the document. The exact algorithm for versioning is decided by the producer/custodian",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.version",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.attestation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.attestation",
        "short": "Document attestation details",
        "definition": "Document attestation details",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSDocument.header.attestation",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.attestation.attester[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.attestation.attester[x]",
        "short": "Attester who validated the document",
        "definition": "Attester who validated laboratory result report. Multiple attesters could be provided.",
        "comment": "Attestation (validation) of the laboratory report content is the usual step before legal authentication. Attestation could be provided by e.g. the laboratory specialist or the laboratory information system based on internal rules of the laboratory.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.attestation.attester[x]",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSHealthProfessional"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDevice"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.attestation.datetime",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.attestation.datetime",
        "short": "Date and time of the approval of the document by Attester",
        "definition": "Date and time of the approval of the document by Attester",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.attestation.datetime",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.legalAuthentication",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.legalAuthentication",
        "short": "Document legal authentication details",
        "definition": "Document legal authentication details",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSDocument.header.legalAuthentication",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.legalAuthentication.legalAuthenticator[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.legalAuthentication.legalAuthenticator[x]",
        "short": "The person or organisation taking responsibility for the content of the document.",
        "definition": "The person or organization taking responsibility for the medical content of the document",
        "comment": "Legal authentication of the laboratory report is the usual step after attestation. Legal authentication could be provided by e.g. the head of the laboratory or the laboratory organization itself.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.legalAuthentication.legalAuthenticator[x]",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSHealthProfessional"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSOrganisation"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.legalAuthentication.datetime",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.legalAuthentication.datetime",
        "short": "Date and time when the document was authorised",
        "definition": "Date and time when the document was authorised",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.legalAuthentication.datetime",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.eventType",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.eventType",
        "short": "Categorisation of the event covered by the document (e.g. laboratory study types, imaging study types including modality, etc.). Selection of such tags or labels depends on the use case and agreement between data sharing parties. This meta-data element serves primarily for searching and filtering purposes.",
        "definition": "Categorisation of the event covered by the document (e.g. laboratory study types, imaging study types including modality, etc.). Selection of such tags or labels depends on the use case and agreement between data sharing parties. This meta-data element serves primarily for searching and filtering purposes.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSDocument.header.eventType",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "SNOMED CT"
        }
      },
      {
        "id": "EHDSLaboratoryReport.header.serviceSpecialty",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.serviceSpecialty",
        "short": "Additional details about where the content was created (e.g. clinical specialty)",
        "definition": "Additional details about where the content was created (e.g. clinical specialty)",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSDocument.header.serviceSpecialty",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "SNOMED CT"
        }
      },
      {
        "id": "EHDSLaboratoryReport.header.custodian",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.custodian",
        "short": "Organisation that is in charge of maintaining the document/report.",
        "definition": "Organisation that is in charge of maintaining the document/report.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSDocument.header.custodian",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSOrganisation"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.presentedForm",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Each EHR system that is a producer of a laboratory report SHALL be able to provide the entire report as issued by the laboratory in a human readable format, e.g. PDF."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHALL process the human readable version of the report."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHALL render human readable version of the report to the endusers."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.presentedForm",
        "short": "A narrative easy-to-read representation of the full data set, e.g. PDF-version of a document",
        "definition": "A narrative easy-to-read representation of the full data set, e.g. PDF-version of a document",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSDocument.presentedForm",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSAttachment"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.header.intendedRecipient[x]",
        "path": "EHDSLaboratoryReport.header.intendedRecipient[x]",
        "short": "Intended recipient",
        "definition": "Information recipient (intended recipient or recipients of the report, additional recipients might be identified by the ordering party, e.g. GP, other specialist), if applicable",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.header.intendedRecipient[x]",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSPatient"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSRelatedPerson"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSHealthProfessional"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSOrganisation"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSDevice"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Each EHR system that is a producer of a laboratory report SHALL be able to provide structured information about the laboratory investigation, such as order information, supporting information, specimen details and result data."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHALL process structured body information."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body",
        "short": "Laboratory Report structured body",
        "definition": "Laboratory Report structured body",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSLaboratoryReport.body",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems SHALL be able to populate information about one or more order which this report is based on."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Consumer EHR systems SHALL display key order information to ensure traceability between order and report."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation",
        "short": "Order Information (Laboratory Result Report could respond to multiple test orders)",
        "definition": "Order Information (Laboratory Result Report could respond to multiple test orders)",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.orderInformation",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.orderId",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Consumer systems SHOULD use this element to pair result report with laboratory order. "
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation.orderId",
        "short": "An identifier of the laboratory test order. Laboratory Result Report may respond to multiple orders.",
        "definition": "An identifier of the laboratory test order. Laboratory Result Report may respond to multiple orders.",
        "min": 1,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.orderInformation.orderId",
          "min": 1,
          "max": "*"
        },
        "type": [
          {
            "code": "Identifier"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.orderDateAndTime",
        "path": "EHDSLaboratoryReport.body.orderInformation.orderDateAndTime",
        "short": "Date and time of the order placement.",
        "definition": "Date and time of the order placement.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSLaboratoryReport.body.orderInformation.orderDateAndTime",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "dateTime"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.orderPlacer[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation.orderPlacer[x]",
        "short": "The person/organisation \"authorised\" to place the order. Order placer could be either a health professional, health professional organisation or the patient himself.",
        "definition": "The person/organisation \"authorised\" to place the order. Order placer could be either a health professional, health professional organisation or the patient himself.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSLaboratoryReport.body.orderInformation.orderPlacer[x]",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSHealthProfessional"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSOrganisation"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSPatient"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.orderReason[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation.orderReason[x]",
        "short": "An explanation or justification for why this service is being requested in coded form.",
        "definition": "An explanation or justification for why this service is being requested in coded form.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.orderInformation.orderReason[x]",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "CodeableConcept"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSCondition"
          },
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSObservation"
          },
          {
            "code": "string"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "SNOMED CT"
        }
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.clinicalQuestion",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation.clinicalQuestion",
        "short": "Specification of clinical question (goal of the investigation) to be answered by the laboratory investigation.",
        "definition": "Specification of clinical question (goal of the investigation) to be answered by the laboratory investigation.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSLaboratoryReport.body.orderInformation.clinicalQuestion",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "string"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation",
        "short": "Additional clinical information about the patient or specimen that may influence the services or their interpretations. This information includes diagnosis, clinical findings and other observations. In laboratory ordering these are typically referred to as 'ask at order entry questions (AOEs).' This includes observations explicitly requested by the producer (filler) to provide context or supporting information needed to complete the order. For example, reporting the amount of inspired oxygen for blood gas measurements.",
        "definition": "Additional clinical information about the patient or specimen that may influence the services or their interpretations. This information includes diagnosis, clinical findings and other observations. In laboratory ordering these are typically referred to as 'ask at order entry questions (AOEs).' This includes observations explicitly requested by the producer (filler) to provide context or supporting information needed to complete the order. For example, reporting the amount of inspired oxygen for blood gas measurements.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSLaboratoryReport.body.supportingInformation",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.observation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.observation",
        "short": "Clinical findings and other observations.",
        "definition": "Clinical findings and other observations.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.supportingInformation.observation",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSObservation"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.condition",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.condition",
        "short": "Condition that may influence the service or result interpretation.",
        "definition": "Condition that may influence the service or result interpretation.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.supportingInformation.condition",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSCondition"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.medicationAdministration",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.medicationAdministration",
        "short": "Medication administered before ordering the service.",
        "definition": "Medication administered before ordering the service.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.supportingInformation.medicationAdministration",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSMedicationAdministration"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.sexForClinicalUse",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.sexForClinicalUse",
        "short": "A Sex Parameter for Clinical Use is a parameter that provides guidance on how a recipient should apply settings or reference ranges that are derived from observable information such as an organ inventory, recent hormone lab tests, genetic testing, menstrual status, obstetric history, etc.. This property is intended for use in clinical decision making, and indicates that treatment or diagnostic tests should consider best practices associated with the relevant reference population",
        "definition": "A Sex Parameter for Clinical Use is a parameter that provides guidance on how a recipient should apply settings or reference ranges that are derived from observable information such as an organ inventory, recent hormone lab tests, genetic testing, menstrual status, obstetric history, etc.. This property is intended for use in clinical decision making, and indicates that treatment or diagnostic tests should consider best practices associated with the relevant reference population",
        "min": 0,
        "max": "1",
        "base": {
          "path": "EHDSLaboratoryReport.body.supportingInformation.sexForClinicalUse",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "preferred",
          "description": "HL7 sex-parameter-for-clinical-use"
        }
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.vaccination",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.vaccination",
        "short": "Vaccination history of the patient.",
        "definition": "Vaccination history of the patient.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.supportingInformation.vaccination",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSImmunisation"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.otherSupportingInformation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.otherSupportingInformation",
        "short": "Any other type of relevant supporting information",
        "definition": "Any other type of relevant supporting information",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.supportingInformation.otherSupportingInformation",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Resource"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.specimen",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.specimen",
        "short": "Specimen information",
        "definition": "Specimen information",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.specimen",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSSpecimen"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.serviceRequest",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.serviceRequest",
        "short": "Specification of requested service or services",
        "definition": "Specification of requested service or services",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.serviceRequest",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSServiceRequest"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.resultData",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.resultData",
        "short": "Laboratory report result data",
        "definition": "Laboratory report result data",
        "min": 1,
        "max": "1",
        "base": {
          "path": "EHDSLaboratoryReport.body.resultData",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "code": "Base"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.resultData.commentsInterpretationAndRecommendations",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.resultData.commentsInterpretationAndRecommendations",
        "short": "Narrative Comments, such as a textual interpretation or advice accompanying the result report, for example.",
        "definition": "Narrative Comments, such as a textual interpretation or advice accompanying the result report, for example.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.resultData.commentsInterpretationAndRecommendations",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Narrative"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.body.resultData.laboratoryTestResults",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.resultData.laboratoryTestResults",
        "short": "Observation details (report could consist of multiple observations)",
        "definition": "Observation details (report could consist of multiple observations)",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.body.resultData.laboratoryTestResults",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryObservation"
          }
        ]
      },
      {
        "id": "EHDSLaboratoryReport.attachments",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Each EHR system that is a producer of a laboratory report SHOULD be able to provide attachments related to the report, such as documents, diagrams, images of the results, etc."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHOULD process attachments related to the report."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHOULD render attachments related to the report to the endusers."
              },
              {
                "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-source",
                "valueCanonical": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSLaboratoryReportObligations|0.4.0"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.attachments",
        "short": "Report attachments",
        "definition": "Report attachments",
        "min": 0,
        "max": "*",
        "base": {
          "path": "EHDSLaboratoryReport.attachments",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "http://www.xt-ehr.eu/fhir/models/StructureDefinition/EHDSAttachment"
          }
        ]
      }
    ]
  },
  "differential": {
    "element": [
      {
        "id": "EHDSLaboratoryReport",
        "path": "EHDSLaboratoryReport"
      },
      {
        "id": "EHDSLaboratoryReport.header",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Each producer of a laboratory report SHALL be able to provide basic information, such as type of the report, authorship, status of the report, title, etc. This information is crucial for safe identification of the report and for searchability of the report using standardized searching parameters."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHALL process document header information."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header"
      },
      {
        "id": "EHDSLaboratoryReport.header.subject",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems SHALL provide information about the subject of care."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR system SHALL render information about the subject of care in such a way that unambiguous assignment to the care subject is preserved."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Information about the subject of care SHALL be processed by the EHR system in such a way that the identity of the subject of care cannot be confused."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.subject"
      },
      {
        "id": "EHDSLaboratoryReport.header.identifier",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.identifier"
      },
      {
        "id": "EHDSLaboratoryReport.header.author[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.author[x]"
      },
      {
        "id": "EHDSLaboratoryReport.header.date",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.date"
      },
      {
        "id": "EHDSLaboratoryReport.header.status",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.status"
      },
      {
        "id": "EHDSLaboratoryReport.header.language",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.language"
      },
      {
        "id": "EHDSLaboratoryReport.header.documentType",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.documentType"
      },
      {
        "id": "EHDSLaboratoryReport.header.documentTitle",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.documentTitle"
      },
      {
        "id": "EHDSLaboratoryReport.header.period",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.period"
      },
      {
        "id": "EHDSLaboratoryReport.header.attestation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.attestation"
      },
      {
        "id": "EHDSLaboratoryReport.header.attestation.attester[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.attestation.attester[x]"
      },
      {
        "id": "EHDSLaboratoryReport.header.attestation.datetime",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.attestation.datetime"
      },
      {
        "id": "EHDSLaboratoryReport.header.legalAuthentication",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.legalAuthentication"
      },
      {
        "id": "EHDSLaboratoryReport.header.legalAuthentication.legalAuthenticator[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.legalAuthentication.legalAuthenticator[x]"
      },
      {
        "id": "EHDSLaboratoryReport.header.legalAuthentication.datetime",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.legalAuthentication.datetime"
      },
      {
        "id": "EHDSLaboratoryReport.header.eventType",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.eventType"
      },
      {
        "id": "EHDSLaboratoryReport.header.serviceSpecialty",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.serviceSpecialty"
      },
      {
        "id": "EHDSLaboratoryReport.header.custodian",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.header.custodian"
      },
      {
        "id": "EHDSLaboratoryReport.presentedForm",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Each EHR system that is a producer of a laboratory report SHALL be able to provide the entire report as issued by the laboratory in a human readable format, e.g. PDF."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHALL process the human readable version of the report."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHALL render human readable version of the report to the endusers."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.presentedForm"
      },
      {
        "id": "EHDSLaboratoryReport.body",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Each EHR system that is a producer of a laboratory report SHALL be able to provide structured information about the laboratory investigation, such as order information, supporting information, specimen details and result data."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHALL process structured body information."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body"
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems SHALL be able to populate information about one or more order which this report is based on."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Consumer EHR systems SHALL display key order information to ensure traceability between order and report."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation"
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.orderId",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Consumer systems SHOULD use this element to pair result report with laboratory order. "
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation.orderId"
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.orderPlacer[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation.orderPlacer[x]"
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.orderReason[x]",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation.orderReason[x]"
      },
      {
        "id": "EHDSLaboratoryReport.body.orderInformation.clinicalQuestion",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.orderInformation.clinicalQuestion"
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation"
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.observation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.observation"
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.condition",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.condition"
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.medicationAdministration",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.medicationAdministration"
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.sexForClinicalUse",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.sexForClinicalUse"
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.vaccination",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.vaccination"
      },
      {
        "id": "EHDSLaboratoryReport.body.supportingInformation.otherSupportingInformation",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.supportingInformation.otherSupportingInformation"
      },
      {
        "id": "EHDSLaboratoryReport.body.specimen",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.specimen"
      },
      {
        "id": "EHDSLaboratoryReport.body.serviceRequest",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.serviceRequest"
      },
      {
        "id": "EHDSLaboratoryReport.body.resultData",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.resultData"
      },
      {
        "id": "EHDSLaboratoryReport.body.resultData.commentsInterpretationAndRecommendations",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.resultData.commentsInterpretationAndRecommendations"
      },
      {
        "id": "EHDSLaboratoryReport.body.resultData.laboratoryTestResults",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHALL:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.body.resultData.laboratoryTestResults"
      },
      {
        "id": "EHDSLaboratoryReport.attachments",
        "extension": [
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:able-to-populate"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-producer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "Each EHR system that is a producer of a laboratory report SHOULD be able to provide attachments related to the report, such as documents, diagrams, images of the results, etc."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:process"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHOULD process attachments related to the report."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          },
          {
            "extension": [
              {
                "url": "code",
                "valueCode": "SHOULD:display"
              },
              {
                "url": "actor",
                "valueCanonical": "https://www.xt-ehr.eu/specifications/fhir/actor-consumer"
              },
              {
                "url": "documentation",
                "valueMarkdown": "EHR systems that consume laboratory report SHOULD render attachments related to the report to the endusers."
              }
            ],
            "url": "http://hl7.org/fhir/StructureDefinition/obligation"
          }
        ],
        "path": "EHDSLaboratoryReport.attachments"
      }
    ]
  }
}