Package | us.nlm.vsac |
Resource Type | ValueSet |
Id | 2.16.840.1.113883.3.3157.190412 |
FHIR Version | R4 |
Source | http://fhir.org/packages/us.nlm.vsac/https://vsac.nlm.nih.gov/valueset/2.16.840.1.113883.3.3157.190412/expansion |
URL | http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.3157.190412 |
Version | 20180418 |
Status | active |
Date | 2018-04-18T01:00:00-04:00 |
Name | ScreeningMammographyAndDBTStudies |
Title | Screening Mammography and DBT Studies |
Realm | us |
Authority | hl7 |
Description | This value set is associated with the "Breast Cancer Screening Recall Rates" measure used in the Centers for Medicare & Medicaid Services (CMS) Hospital Outpatient Quality Reporting (OQR) Program. It is also referred to as "OP-39." |
Purpose | (Clinical Focus: This set of values contains CPT and HCPCS codes associated with screening studies used to identify breast cancer in men and women.),(Data Element Scope: The intent of this data element is to identify patients who underwent a screening mammography or screening digital breast tomosynthesis (DBT).),(Inclusion Criteria: CPT and HCPCS codes that identify breast screening imaging studies performed using traditional mammography or DBT are captured in this value set.),(Exclusion Criteria: Codes not associated with breast screening are excluded from this value set. Similarly, codes from alternative terminologies other than CPT and HCPCS are excluded from this value set.) |
No resources found
CodeSystem | |
cpt | Current Procedural Terminology (CPT®) |
HCPCSReleaseCodeSets | Healthcare Common Procedure Coding System (HCPCS) level II alphanumeric codes |
No narrative content found in resource
{ "resourceType": "ValueSet", "id": "2.16.840.1.113883.3.3157.190412", "meta": { "versionId": "5", "lastUpdated": "2024-12-02T16:03:48.000-05:00", "profile": [ "http://hl7.org/fhir/StructureDefinition/shareablevalueset", "http://hl7.org/fhir/us/cqfmeasures/StructureDefinition/computable-valueset-cqfm", "http://hl7.org/fhir/us/cqfmeasures/StructureDefinition/publishable-valueset-cqfm" ] }, "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-author", "valueContactDetail": { "name": "Acumen OP Author" } }, { "url": "http://hl7.org/fhir/StructureDefinition/resource-lastReviewDate", "valueDate": "2024-04-22" }, { "url": "http://hl7.org/fhir/StructureDefinition/valueset-effectiveDate", "valueDate": "2018-04-18" } ], "url": "http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.3157.190412", "identifier": [ { "system": "urn:ietf:rfc:3986", "value": "urn:oid:2.16.840.1.113883.3.3157.190412" } ], "version": "20180418", "name": "ScreeningMammographyAndDBTStudies", "title": "Screening Mammography and DBT Studies", "status": "active", "experimental": false, "date": "2018-04-18T01:00:00-04:00", "publisher": "Acumen OP Steward", "description": "This value set is associated with the \"Breast Cancer Screening Recall Rates\" measure used in the Centers for Medicare & Medicaid Services (CMS) Hospital Outpatient Quality Reporting (OQR) Program. It is also referred to as \"OP-39.\"", "jurisdiction": [ { "coding": [ { "system": "urn:iso:std:iso:3166", "code": "US" } ] } ], "purpose": "(Clinical Focus: This set of values contains CPT and HCPCS codes associated with screening studies used to identify breast cancer in men and women.),(Data Element Scope: The intent of this data element is to identify patients who underwent a screening mammography or screening digital breast tomosynthesis (DBT).),(Inclusion Criteria: CPT and HCPCS codes that identify breast screening imaging studies performed using traditional mammography or DBT are captured in this value set.),(Exclusion Criteria: Codes not associated with breast screening are excluded from this value set. Similarly, codes from alternative terminologies other than CPT and HCPCS are excluded from this value set.)", "compose": { "include": [ { "valueSet": [ "http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.3157.1904" ] }, { "valueSet": [ "http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113883.3.3157.19041" ] } ] }, "expansion": { "identifier": "urn:uuid:17f3bd00-2ce8-4f5d-b2ad-e15c5180be34", "timestamp": "2025-05-23T22:02:25-04:00", "total": 4, "contains": [ { "system": "http://www.ama-assn.org/go/cpt", "version": "2025", "code": "77063", "display": "Screening digital breast tomosynthesis, bilateral (List separately in addition to code for primary procedure)" }, { "system": "http://www.ama-assn.org/go/cpt", "version": "2025", "code": "77067", "display": "Screening mammography, bilateral (2-view study of each breast), including computer-aided detection (CAD) when performed" }, { "system": "http://www.cms.gov/Medicare/Coding/HCPCSReleaseCodeSets", "version": "2025", "code": "G9899", "display": "Screening, diagnostic, film, digital or digital breast tomosynthesis (3d) mammography results documented and reviewed" }, { "system": "http://www.cms.gov/Medicare/Coding/HCPCSReleaseCodeSets", "version": "2025", "code": "G9900", "display": "Screening, diagnostic, film, digital or digital breast tomosynthesis (3d) mammography results were not documented and reviewed, reason not otherwise specified" } ] } }