FHIR IG Statistics: StructureDefinition/Communication.StructureDefinition
Resources that use this resource
Resources that this resource uses
Narrative
No narrative content found in resource
Source
{
"resourceType": "StructureDefinition",
"url": "http://fhir.synapxe.sg/StructureDefinition/profile-communication",
"name": "Communication",
"status": "active",
"description": "This resource defines the communication alert for the remote clinical monitoring of the patient. Details like the type of alert and the patient id will be used. The observation id will also be stored depending on the alert code (i.e \"Threshold\" and \"Missed Read\").",
"fhirVersion": "5.0.0",
"kind": "resource",
"abstract": false,
"type": "Communication",
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/Communication",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "Communication.identifier",
"path": "Communication.identifier",
"max": "0"
},
{
"id": "Communication.instantiatesCanonical",
"path": "Communication.instantiatesCanonical",
"max": "0"
},
{
"id": "Communication.instantiatesUri",
"path": "Communication.instantiatesUri",
"max": "0"
},
{
"id": "Communication.basedOn",
"path": "Communication.basedOn",
"max": "0"
},
{
"id": "Communication.partOf",
"path": "Communication.partOf",
"max": "0"
},
{
"id": "Communication.inResponseTo",
"path": "Communication.inResponseTo",
"max": "0"
},
{
"id": "Communication.statusReason",
"path": "Communication.statusReason",
"max": "0"
},
{
"id": "Communication.category",
"path": "Communication.category",
"min": 1,
"max": "1"
},
{
"id": "Communication.category.coding",
"path": "Communication.category.coding",
"min": 1,
"max": "1"
},
{
"id": "Communication.category.coding.system",
"path": "Communication.category.coding.system",
"min": 1,
"fixedUri": "http://terminology.hl7.org/CodeSystem/communication-category"
},
{
"id": "Communication.category.coding.version",
"path": "Communication.category.coding.version",
"max": "0"
},
{
"id": "Communication.category.coding.code",
"path": "Communication.category.coding.code",
"min": 1,
"fixedCode": "alert"
},
{
"id": "Communication.category.coding.display",
"path": "Communication.category.coding.display",
"max": "0"
},
{
"id": "Communication.category.coding.userSelected",
"path": "Communication.category.coding.userSelected",
"max": "0"
},
{
"id": "Communication.category.text",
"path": "Communication.category.text",
"max": "0"
},
{
"id": "Communication.priority",
"path": "Communication.priority",
"max": "0"
},
{
"id": "Communication.medium",
"path": "Communication.medium",
"max": "0"
},
{
"id": "Communication.subject",
"path": "Communication.subject",
"min": 1,
"type": [
{
"code": "Reference",
"targetProfile": [
"http://fhir.synapxe.sg/StructureDefinition/profile-patient"
]
}
]
},
{
"id": "Communication.subject.reference",
"path": "Communication.subject.reference",
"min": 1
},
{
"id": "Communication.subject.type",
"path": "Communication.subject.type",
"max": "0"
},
{
"id": "Communication.subject.identifier",
"path": "Communication.subject.identifier",
"max": "0"
},
{
"id": "Communication.subject.display",
"path": "Communication.subject.display",
"max": "0"
},
{
"id": "Communication.topic",
"path": "Communication.topic",
"max": "0"
},
{
"id": "Communication.about",
"path": "Communication.about",
"max": "1",
"type": [
{
"code": "Reference",
"targetProfile": [
"http://fhir.synapxe.sg/StructureDefinition/profile-observation"
]
}
]
},
{
"id": "Communication.about.reference",
"path": "Communication.about.reference",
"min": 1
},
{
"id": "Communication.about.type",
"path": "Communication.about.type",
"max": "0"
},
{
"id": "Communication.about.identifier",
"path": "Communication.about.identifier",
"max": "0"
},
{
"id": "Communication.about.display",
"path": "Communication.about.display",
"max": "0"
},
{
"id": "Communication.encounter",
"path": "Communication.encounter",
"max": "0"
},
{
"id": "Communication.sent",
"path": "Communication.sent",
"min": 1
},
{
"id": "Communication.received",
"path": "Communication.received",
"max": "0"
},
{
"id": "Communication.recipient",
"path": "Communication.recipient",
"max": "0"
},
{
"id": "Communication.sender",
"path": "Communication.sender",
"max": "0"
},
{
"id": "Communication.reason",
"path": "Communication.reason",
"min": 1,
"max": "1"
},
{
"id": "Communication.reason.concept",
"path": "Communication.reason.concept",
"min": 1,
"binding": {
"strength": "required",
"description": "The communication alert codes used in RCM.",
"valueSet": "http://fhir.synapxe.sg/ValueSet/rcm-communication-alert-codes"
}
},
{
"id": "Communication.reason.concept.coding",
"path": "Communication.reason.concept.coding",
"min": 1,
"max": "1"
},
{
"id": "Communication.reason.concept.coding.system",
"path": "Communication.reason.concept.coding.system",
"min": 1,
"fixedUri": "http://fhir.synapxe.sg/CodeSystem/rcm-communication-alert-codes"
},
{
"id": "Communication.reason.concept.coding.version",
"path": "Communication.reason.concept.coding.version",
"max": "0"
},
{
"id": "Communication.reason.concept.coding.code",
"path": "Communication.reason.concept.coding.code",
"min": 1
},
{
"id": "Communication.reason.concept.coding.display",
"path": "Communication.reason.concept.coding.display",
"max": "0"
},
{
"id": "Communication.reason.concept.coding.userSelected",
"path": "Communication.reason.concept.coding.userSelected",
"max": "0"
},
{
"id": "Communication.reason.concept.text",
"path": "Communication.reason.concept.text",
"max": "0"
},
{
"id": "Communication.reason.reference",
"path": "Communication.reason.reference",
"max": "0"
},
{
"id": "Communication.payload",
"path": "Communication.payload",
"max": "0"
},
{
"id": "Communication.note",
"path": "Communication.note",
"max": "0"
}
]
}
}