FHIR IG analytics| Package | silfhirprofileig |
| Resource Type | ValueSet |
| Id | ValueSet-specimen-condition-at-collection.json |
| FHIR Version | R5 |
| Source | https://build.fhir.org/ig/savannahghi/sil_fhir_profile_ig/ValueSet-specimen-condition-at-collection.html |
| URL | https://fhir.slade360.co.ke/fhir/ValueSet/specimen-condition-at-collection |
| Version | 0.1.0 |
| Status | active |
| Date | 2026-10-02T07:33:51+00:00 |
| Name | SGHISpecimenConditionAtCollection |
| Title | SGHI Specimen Condition At Collection |
| Description | How the draw went, recorded by whoever took the sample. A difficult or short draw does not reject the sample; it travels with it so the laboratory can read the result in light of it. |
No resources found
| CodeSystem | ||
| hl7.terminology#current | v2-0493 | specimenCondition |
| silfhirprofileig#current | specimen-collection-codesystem | SGHI Specimen Collection Code System |
Note: links and images are rebased to the (stated) source
Generated Narrative: ValueSet specimen-condition-at-collection
This value set includes codes based on the following rules:
https://fhir.slade360.co.ke/fhir/CodeSystem/specimen-collection-codesystem version 📦0.1.0| Code | Display | Definition |
| clean-draw | Clean draw | The draw went cleanly and the sample is fit for testing. |
| difficult-draw | Difficult draw | The draw needed more than one attempt or prolonged venous access. The sample stands, but results sensitive to a traumatic draw are read with it in mind. |
| short-draw | Short draw, under volume | The container was filled below its target volume. It matters most where the blood-to-additive ratio is fixed, as in a citrate tube. |
http://terminology.hl7.org/CodeSystem/v2-0493 version 📦3.0.0| Code | Display | Definition |
| HEM | Visibly haemolysed | Hemolyzed |
{
"resourceType": "ValueSet",
"id": "specimen-condition-at-collection",
"text": {
"status": "extensions",
"div": "<!-- snip (see above) -->"
},
"url": "https://fhir.slade360.co.ke/fhir/ValueSet/specimen-condition-at-collection",
"version": "0.1.0",
"name": "SGHISpecimenConditionAtCollection",
"title": "SGHI Specimen Condition At Collection",
"status": "active",
"experimental": false,
"date": "2026-10-02T07:33:51+00:00",
"publisher": "Kathurima Kimathi",
"contact": [
{
"name": "Kathurima Kimathi",
"telecom": [
{
"system": "url",
"value": "https://www.linkedin.com/in/kathurima-kimathi/"
},
{
"system": "email",
"value": "kathurimakimathi415@gmail.com"
}
]
},
{
"name": "Oscar John",
"telecom": [
{
"system": "email",
"value": "oscarjohnotieno@gmail.com",
"use": "work"
}
]
},
{
"name": "Kennedy Omondi",
"telecom": [
{
"system": "email",
"value": "kennankole@gmail.com",
"use": "work"
}
]
}
],
"description": "How the draw went, recorded by whoever took the sample. A difficult or short draw does not reject the sample; it travels with it so the laboratory can read the result in light of it.",
"compose": {
"include": [
{
"system": "https://fhir.slade360.co.ke/fhir/CodeSystem/specimen-collection-codesystem",
"concept": [
{
"code": "clean-draw",
"display": "Clean draw"
},
{
"code": "difficult-draw",
"display": "Difficult draw"
},
{
"code": "short-draw",
"display": "Short draw, under volume"
}
]
},
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0493",
"concept": [
{
"code": "HEM",
"display": "Visibly haemolysed"
}
]
}
]
}
}