Package | openehr.base |
Type | StructureDefinition |
Id | DV-COUNT |
FHIR Version | R5 |
Source | http://openehr.org/fhir/https://build.fhir.org/ig/FHIR/openehr-base-ig/StructureDefinition-DV-COUNT.html |
URL | http://openehr.org/fhir/StructureDefinition/DV-COUNT |
Version | 0.1.0 |
Status | active |
Date | 2023-06-27T18:45:58+10:00 |
Name | DV_COUNT |
Title | DV_COUNT |
Realm | uv |
Authority | hl7 |
Description | Countable quantities. Used for countable types such as pregnancies and steps (taken by a physiotherapy patient), number of cigarettes smoked in a day. |
Type | http://openehr.org/fhir/StructureDefinition/DV_COUNT |
Kind | logical |
No resources found
StructureDefinition | |
DV-AMOUNT | DV_AMOUNT |
DV-INTERVAL | DV_INTERVAL |
REFERENCE-RANGE | REFERENCE_RANGE |
Note: links and images are rebased to the (stated) source
Generated Narrative: StructureDefinition DV-COUNT
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
![]() ![]() | 0..* | DV_AMOUNT | Elements defined in Ancestors:normal_status, normal_range, other_reference_ranges, magnitude_status, accuracy, accuracy_is_percent, accuracy Countable quantities. Used for countable types | |
![]() ![]() ![]() | 1..1 | decimal | Numeric magnitude | |
![]() ![]() ![]() | 0..1 | DV_INTERVAL<DV_COUNT> | If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value | |
![]() ![]() ![]() | 0..* | REFERENCE_RANGE<DV_COUNT> | If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value | |
{ "resourceType": "StructureDefinition", "id": "DV-COUNT", "text": { "status": "extensions", "div": "<!-- snip (see above) -->" }, "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/web-source", "valueUrl": "https://specifications.openehr.org/releases/RM/Release-1.1.0/data_types.html#_dv_count_class" }, { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode": "fhir" }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/view-hint", "valueCode": "element-view-as-leaf" }, { "url": "http://hl7.org/fhir/tools/StructureDefinition/view-hint", "valueCode": "element-view-defns-parent" }, { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm", "valueInteger": 3, "_valueInteger": { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom", "valueCanonical": "http://openehr.org/fhir/ImplementationGuide/openehr.base" } ] } }, { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status", "valueCode": "informative", "_valueCode": { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom", "valueCanonical": "http://openehr.org/fhir/ImplementationGuide/openehr.base" } ] } } ], "url": "http://openehr.org/fhir/StructureDefinition/DV-COUNT", "version": "0.1.0", "name": "DV_COUNT", "title": "DV_COUNT", "status": "active", "experimental": false, "date": "2023-06-27T18:45:58+10:00", "publisher": "openEHR + HL7", "contact": [ { "telecom": [ { "system": "url", "value": "http://www.openehr.org" } ] } ], "description": "Countable quantities. Used for countable types such as pregnancies and steps (taken by a physiotherapy patient), number of cigarettes smoked in a day.", "jurisdiction": [ { "coding": [ { "system": "http://unstats.un.org/unsd/methods/m49/m49.htm", "code": "001" } ] } ], "fhirVersion": "5.0.0", "mapping": [ { "identity": "rim", "uri": "http://hl7.org/v3", "name": "RIM Mapping" } ], "kind": "logical", "abstract": false, "type": "http://openehr.org/fhir/StructureDefinition/DV_COUNT", "baseDefinition": "http://openehr.org/fhir/StructureDefinition/DV-AMOUNT", "derivation": "specialization", "snapshot": { "extension": [ { "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version", "valueString": "0.1.0" } ], "element": [ { "id": "DV_COUNT", "path": "DV_COUNT", "short": "Countable quantities. Used for countable types", "definition": "Countable quantities. Used for countable types such as pregnancies and steps (taken by a physiotherapy patient), number of cigarettes smoked in a day.", "comment": "Misuse: Not to be used for amounts of physical entities (which all have units).", "min": 0, "max": "*", "base": { "path": "Base", "min": 0, "max": "*" }, "isModifier": false, "mapping": [ { "identity": "rim", "map": "n/a" } ] }, { "id": "DV_COUNT.normal-status", "path": "DV_COUNT.normal_status", "short": "Optional normal status indicator of value with respect to normal range for this value", "definition": "Optional normal status indicator of value with respect to normal range for this value. Often included by lab, even if the normal range itself is not included. Coded by ordinals in series HHH, HH, H, (nothing), L, LL, LLL; see openEHR terminology group normal_status.", "min": 0, "max": "1", "base": { "path": "DV_ORDERED.normal_status", "min": 0, "max": "1" }, "type": [ { "code": "http://openehr.org/fhir/StructureDefinition/CODE-PHRASE" } ], "isModifier": false, "binding": { "strength": "required", "valueSet": "https://specifications.openehr.org/fhir/valueset-normal_statuses" } }, { "id": "DV_COUNT.normal-range", "path": "DV_COUNT.normal_range", "short": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value", "definition": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value.", "min": 0, "max": "1", "base": { "path": "DV_ORDERED.normal_range", "min": 0, "max": "1" }, "type": [ { "extension": [ { "extension": [ { "url": "name", "valueCode": "T" }, { "url": "type", "valueUri": "http://openehr.org/fhir/StructureDefinition/DV-COUNT" } ], "url": "http://hl7.org/fhir/tools/StructureDefinition/type-parameter" } ], "code": "http://openehr.org/fhir/StructureDefinition/DV-INTERVAL" } ], "isModifier": false }, { "id": "DV_COUNT.other-reference-ranges", "path": "DV_COUNT.other_reference_ranges", "short": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value", "definition": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value.", "min": 0, "max": "*", "base": { "path": "DV_ORDERED.other_reference_ranges", "min": 0, "max": "*" }, "type": [ { "extension": [ { "extension": [ { "url": "name", "valueCode": "T" }, { "url": "type", "valueUri": "http://openehr.org/fhir/StructureDefinition/DV-COUNT" } ], "url": "http://hl7.org/fhir/tools/StructureDefinition/type-parameter" } ], "code": "http://openehr.org/fhir/StructureDefinition/REFERENCE-RANGE" } ], "isModifier": false }, { "id": "DV_COUNT.magnitude-status", "path": "DV_COUNT.magnitude_status", "short": "Optional status of magnitude: =, <, >, <=, >=, ~", "definition": "Optional status of magnitude with values:\r\n* '=' : magnitude is a point value\r\n* '<' : value is < magnitude\r\n* '>' : value is > magnitude\r\n* '<=' : value is <= magnitude\r\n* '>=' : value is >= magnitude\r\n* '~' : value is approximately magnitude\r\n\r\nIf not present, assumed meaning is '=' .", "min": 0, "max": "1", "base": { "path": "DV_QUANTIFIED.magnitude_status", "min": 0, "max": "1" }, "type": [ { "code": "string" } ], "isModifier": false }, { "id": "DV_COUNT.accuracy", "path": "DV_COUNT.accuracy", "short": "Accuracy of measurement, expressed either as a half-range percent value (accuracy_is_percent = True) or a half-range quantity", "definition": "Accuracy of measurement, expressed either as a half-range percent value (accuracy_is_percent = True) or a half-range quantity. A value of 0 means that accuracy is 100%, i.e. no error.\r\n\r\nA value of unknown_accuracy_value means that accuracy was not recorded.", "min": 0, "max": "1", "base": { "path": "DV_QUANTIFIED.accuracy", "min": 0, "max": "1" }, "type": [ { "code": "decimal" } ], "isModifier": false }, { "id": "DV_COUNT.accuracy-is-percent", "path": "DV_COUNT.accuracy_is_percent", "short": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value", "definition": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value.", "min": 0, "max": "1", "base": { "path": "DV_AMOUNT.accuracy_is_percent", "min": 0, "max": "1" }, "type": [ { "code": "boolean" } ], "isModifier": false }, { "id": "DV_COUNT.magnitude", "path": "DV_COUNT.magnitude", "short": "Numeric magnitude", "definition": "Numeric magnitude.", "min": 1, "max": "1", "base": { "path": "DV_COUNT.magnitude", "min": 1, "max": "1" }, "type": [ { "code": "decimal" } ], "isModifier": false } ] }, "differential": { "element": [ { "id": "DV_COUNT", "path": "DV_COUNT", "short": "Countable quantities. Used for countable types", "definition": "Countable quantities. Used for countable types such as pregnancies and steps (taken by a physiotherapy patient), number of cigarettes smoked in a day.", "comment": "Misuse: Not to be used for amounts of physical entities (which all have units).", "min": 0, "max": "*", "isModifier": false }, { "id": "DV_COUNT.magnitude", "path": "DV_COUNT.magnitude", "short": "Numeric magnitude", "definition": "Numeric magnitude.", "min": 1, "max": "1", "type": [ { "code": "decimal" } ], "isModifier": false }, { "id": "DV_COUNT.normal-range", "path": "DV_COUNT.normal_range", "short": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value", "definition": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value.", "min": 0, "max": "1", "type": [ { "extension": [ { "extension": [ { "url": "name", "valueCode": "T" }, { "url": "type", "valueUri": "http://openehr.org/fhir/StructureDefinition/DV-COUNT" } ], "url": "http://hl7.org/fhir/tools/StructureDefinition/type-parameter" } ], "code": "http://openehr.org/fhir/StructureDefinition/DV-INTERVAL" } ], "isModifier": false }, { "id": "DV_COUNT.other-reference-ranges", "path": "DV_COUNT.other_reference_ranges", "short": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value", "definition": "If True, indicates that when this object was created, accuracy was recorded as a percent value; if False, as an absolute quantity value.", "min": 0, "max": "*", "type": [ { "extension": [ { "extension": [ { "url": "name", "valueCode": "T" }, { "url": "type", "valueUri": "http://openehr.org/fhir/StructureDefinition/DV-COUNT" } ], "url": "http://hl7.org/fhir/tools/StructureDefinition/type-parameter" } ], "code": "http://openehr.org/fhir/StructureDefinition/REFERENCE-RANGE" } ], "isModifier": false } ] } }