FHIR IG analytics
Resources that use this resource
| CapabilityStatement |
| nostalgic-ie.fhir.core#0.2.0 | ie-core-client | IE Core Client CapabilityStatement |
| nostalgic-ie.fhir.core#0.2.0 | ie-core-server | IE Core Server CapabilityStatement |
Resources that this resource uses
| StructureDefinition |
| nostalgic-ie.fhir.core#0.2.0 | ie-core-patient | IE Core Patient |
Narrative
No narrative content found in resource
Source1
{
"resourceType": "StructureDefinition",
"id": "ie-core-procedure",
"url": "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-procedure",
"version": "0.2.0",
"name": "IECoreProcedure",
"title": "IE Core Procedure",
"status": "draft",
"description": "The IE Core Procedure profile sets minimum expectations for the Procedure resource to record, search, and fetch procedure data associated with a patient, based on Irish requirements.",
"fhirVersion": "4.0.1",
"kind": "resource",
"abstract": false,
"type": "Procedure",
"baseDefinition": "http://hl7.org/fhir/StructureDefinition/Procedure",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "Procedure.status",
"path": "Procedure.status",
"comment": "HIQA PS 9.3.4 Status (Mandatory).",
"mustSupport": true
},
{
"id": "Procedure.code",
"path": "Procedure.code",
"comment": "HIQA PS 9.3.2 Procedure name (Mandatory).",
"min": 1,
"mustSupport": true,
"binding": {
"strength": "extensible",
"valueSet": "https://hl7-ie.github.io/ie-core/fhir/ie/core/ValueSet/ie-core-procedure-code"
}
},
{
"id": "Procedure.subject",
"path": "Procedure.subject",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-patient"
]
}
],
"mustSupport": true
},
{
"id": "Procedure.encounter",
"path": "Procedure.encounter",
"mustSupport": true
},
{
"id": "Procedure.performed[x]",
"path": "Procedure.performed[x]",
"comment": "HIQA PS 9.3.1 Date of procedure (Required 0..1). Relaxed from 1..1 so that a procedure with an unknown date can be recorded (OI-012).",
"mustSupport": true
},
{
"id": "Procedure.reasonCode",
"path": "Procedure.reasonCode",
"comment": "HIQA PS 9.3.3 Reason (Required).",
"mustSupport": true
},
{
"id": "Procedure.bodySite",
"path": "Procedure.bodySite",
"comment": "HIQA PS 9.3.5 Anatomical location (Required): location and laterality post-coordinated in SNOMED CT.",
"mustSupport": true
},
{
"id": "Procedure.outcome",
"path": "Procedure.outcome",
"comment": "HIQA PS 9.3.6 Outcome (Optional)."
},
{
"id": "Procedure.complication",
"path": "Procedure.complication",
"comment": "HIQA PS 9.3.7 Complications (Required).",
"mustSupport": true
},
{
"id": "Procedure.focalDevice",
"path": "Procedure.focalDevice",
"comment": "HIQA PS 9.3.8 Device use (Optional)."
}
]
}
}