FHIR IG analytics
Resources that use this resource
| CapabilityStatement |
| nostalgic-ie.fhir.core#0.2.0 | ie-core-client | IE Core Client CapabilityStatement |
| nostalgic-ie.fhir.core#0.2.0 | ie-core-server | IE Core Server CapabilityStatement |
Resources that this resource uses
Narrative
No narrative content found in resource
Source1
{
"resourceType": "StructureDefinition",
"id": "ie-core-medicationdispense-edispensation",
"url": "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationdispense-edispensation",
"version": "0.2.0",
"name": "IECoreMedicationDispenseEDispensation",
"title": "IE Core MedicationDispense (eDispensation)",
"status": "draft",
"description": "An Irish electronic dispensation record (HIQA EP Section 6), derived from the HL7 Europe MPD MedicationDispense. Covers a completed dispense, a partial or instalment dispense, and a non-dispensation (declined or stopped, with a reason).",
"fhirVersion": "4.0.1",
"kind": "resource",
"abstract": false,
"type": "MedicationDispense",
"baseDefinition": "http://hl7.eu/fhir/mpd/StructureDefinition/MedicationDispense-eu-mpd",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "MedicationDispense",
"path": "MedicationDispense",
"constraint": [
{
"key": "ie-md-status-1",
"severity": "error",
"human": "A non-dispensation (declined, stopped, cancelled or on-hold) SHALL state the reason (HIQA EP 6.3.2)",
"expression": "(status = 'declined' or status = 'stopped' or status = 'cancelled' or status = 'on-hold') implies statusReason.exists()",
"source": "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationdispense-edispensation"
},
{
"key": "ie-md-handover-1",
"severity": "error",
"human": "A completed dispense SHALL record when the medication was handed over (HIQA EP 6.8 Date of dispensation, Mandatory)",
"expression": "status = 'completed' implies whenHandedOver.exists()",
"source": "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationdispense-edispensation"
}
]
},
{
"id": "MedicationDispense.extension:recorded",
"path": "MedicationDispense.extension",
"sliceName": "recorded",
"comment": "HIQA EP 6.2 Date and time of issuing the dispense record (Mandatory 1..1); 1..1 inherited from HL7 Europe MPD.",
"mustSupport": true
},
{
"id": "MedicationDispense.extension:receiverRelatedPerson",
"path": "MedicationDispense.extension",
"sliceName": "receiverRelatedPerson",
"min": 0,
"max": "1",
"type": [
{
"code": "Extension",
"profile": [
"https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-dispense-receiver-related-person"
]
}
]
},
{
"id": "MedicationDispense.identifier",
"path": "MedicationDispense.identifier",
"comment": "HIQA EP 6.1 Dispensation identifier (Required 0..*). IE Core requires at least one.",
"min": 1,
"mustSupport": true
},
{
"id": "MedicationDispense.status",
"path": "MedicationDispense.status",
"comment": "HIQA EP 6.3.1 Dispensation status (Mandatory). A non-dispensation uses declined or stopped with a reason (invariant ie-md-status-1).",
"mustSupport": true
},
{
"id": "MedicationDispense.statusReason[x]",
"path": "MedicationDispense.statusReason[x]",
"comment": "HIQA EP 6.3.2 Dispensation status reason (Optional): coded (6.3.2.1) or free text (6.3.2.2, in statusReasonCodeableConcept.text). IE Core requires a reason for a non-dispensation (safety: the prescriber needs to know why).",
"mustSupport": true
},
{
"id": "MedicationDispense.medication[x]",
"path": "MedicationDispense.medication[x]",
"comment": "HIQA EP 6.6 Dispensed medication (Mandatory 1..1); see Section 4.",
"mustSupport": true,
"binding": {
"strength": "extensible",
"valueSet": "https://hl7-ie.github.io/ie-core/fhir/ie/core/ValueSet/ie-core-medication-codes"
}
},
{
"id": "MedicationDispense.subject",
"path": "MedicationDispense.subject",
"min": 1,
"type": [
{
"code": "Reference",
"targetProfile": [
"https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-patient-eprescription"
]
}
],
"mustSupport": true
},
{
"id": "MedicationDispense.performer",
"path": "MedicationDispense.performer",
"comment": "HIQA EP Section 2 (dispenser and pharmacy). Dispensers are registered pharmacists or registered pharmaceutical assistants.",
"min": 1,
"mustSupport": true
},
{
"id": "MedicationDispense.performer.actor",
"path": "MedicationDispense.performer.actor",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-practitioner",
"https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-practitionerrole",
"https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-organization"
]
}
],
"mustSupport": true
},
{
"id": "MedicationDispense.authorizingPrescription",
"path": "MedicationDispense.authorizingPrescription",
"comment": "HIQA EP 6.5 Prescription item identifier with related request (Required 0..1). IE Core requires exactly one (stricter than HIQA, OI-012): this profile covers dispensing against an electronic prescription; emergency supply uses the base IECoreMedicationDispense.",
"min": 1,
"max": "1",
"type": [
{
"code": "Reference",
"targetProfile": [
"https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationrequest-eprescription"
]
}
],
"mustSupport": true
},
{
"id": "MedicationDispense.quantity",
"path": "MedicationDispense.quantity",
"comment": "HIQA EP 6.7 Dispensed quantity (Mandatory 1..1).",
"mustSupport": true
},
{
"id": "MedicationDispense.whenHandedOver",
"path": "MedicationDispense.whenHandedOver",
"comment": "HIQA EP 6.8 Date of dispensation (Mandatory) and 6.9 Time of dispensation (Required). Required when the status is completed (invariant ie-md-handover-1).",
"mustSupport": true
},
{
"id": "MedicationDispense.receiver",
"path": "MedicationDispense.receiver",
"comment": "HIQA EP 6.4 Receiver (Optional): the patient (6.4.1) or a health practitioner (6.4.2). A related person (6.4.3) goes in extension[receiverRelatedPerson]."
},
{
"id": "MedicationDispense.note",
"path": "MedicationDispense.note",
"comment": "HIQA EP 6.12 Additional information (Optional)."
},
{
"id": "MedicationDispense.dosageInstruction",
"path": "MedicationDispense.dosageInstruction",
"comment": "HIQA EP 6.11 Dosage instructions (Required); see Section 5.",
"mustSupport": true
},
{
"id": "MedicationDispense.dosageInstruction.text",
"path": "MedicationDispense.dosageInstruction.text",
"mustSupport": true
},
{
"id": "MedicationDispense.substitution",
"path": "MedicationDispense.substitution",
"mustSupport": true
},
{
"id": "MedicationDispense.substitution.wasSubstituted",
"path": "MedicationDispense.substitution.wasSubstituted",
"comment": "HIQA EP 6.10 Substitution occurred (Optional).",
"mustSupport": true
},
{
"id": "MedicationDispense.substitution.type",
"path": "MedicationDispense.substitution.type",
"mustSupport": true
},
{
"id": "MedicationDispense.substitution.reason",
"path": "MedicationDispense.substitution.reason",
"mustSupport": true
}
]
}
}