FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagenostalgic-ie.fhir.core
Resource TypeStructureDefinition
IdStructureDefinition-ie-core-medicationdispense-edispensation.json
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=nostalgic-ie.fhir.core@0.2.0&canonical=https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationdispense-edispensation
URLhttps://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationdispense-edispensation
Version0.2.0
Statusdraft
NameIECoreMedicationDispenseEDispensation
TitleIE Core MedicationDispense (eDispensation)
DescriptionAn Irish electronic dispensation record (HIQA EP Section 6), derived from the HL7 Europe MPD MedicationDispense. Covers a completed dispense, a partial or instalment dispense, and a non-dispensation (declined or stopped, with a reason).
TypeMedicationDispense
Kindresource

Resources that use this resource

CapabilityStatement
nostalgic-ie.fhir.core#0.2.0ie-core-clientIE Core Client CapabilityStatement
nostalgic-ie.fhir.core#0.2.0ie-core-serverIE Core Server CapabilityStatement

Resources that this resource uses

StructureDefinition
hl7.fhir.eu.mpd#1.0.0MedicationDispense-eu-mpdMedicationDispense: MPD
nostalgic-ie.fhir.core#0.2.0ie-core-dispense-receiver-related-personIE Core Dispense Receiver (Related Person)
nostalgic-ie.fhir.core#0.2.0ie-core-medicationrequest-eprescriptionIE Core MedicationRequest (ePrescription)
nostalgic-ie.fhir.core#0.2.0ie-core-organizationIE Core Organization
nostalgic-ie.fhir.core#0.2.0ie-core-patient-eprescriptionIE Core Patient (ePrescription/eDispensation)
nostalgic-ie.fhir.core#0.2.0ie-core-practitionerIE Core Practitioner
nostalgic-ie.fhir.core#0.2.0ie-core-practitionerroleIE Core PractitionerRole
ValueSet
nostalgic-ie.fhir.core#0.2.0ie-core-medication-codesIE Core Medication Codes

Narrative

No narrative content found in resource


Source1

{
  "resourceType": "StructureDefinition",
  "id": "ie-core-medicationdispense-edispensation",
  "url": "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationdispense-edispensation",
  "version": "0.2.0",
  "name": "IECoreMedicationDispenseEDispensation",
  "title": "IE Core MedicationDispense (eDispensation)",
  "status": "draft",
  "description": "An Irish electronic dispensation record (HIQA EP Section 6), derived from the HL7 Europe MPD MedicationDispense. Covers a completed dispense, a partial or instalment dispense, and a non-dispensation (declined or stopped, with a reason).",
  "fhirVersion": "4.0.1",
  "kind": "resource",
  "abstract": false,
  "type": "MedicationDispense",
  "baseDefinition": "http://hl7.eu/fhir/mpd/StructureDefinition/MedicationDispense-eu-mpd",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "MedicationDispense",
        "path": "MedicationDispense",
        "constraint": [
          {
            "key": "ie-md-status-1",
            "severity": "error",
            "human": "A non-dispensation (declined, stopped, cancelled or on-hold) SHALL state the reason (HIQA EP 6.3.2)",
            "expression": "(status = 'declined' or status = 'stopped' or status = 'cancelled' or status = 'on-hold') implies statusReason.exists()",
            "source": "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationdispense-edispensation"
          },
          {
            "key": "ie-md-handover-1",
            "severity": "error",
            "human": "A completed dispense SHALL record when the medication was handed over (HIQA EP 6.8 Date of dispensation, Mandatory)",
            "expression": "status = 'completed' implies whenHandedOver.exists()",
            "source": "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationdispense-edispensation"
          }
        ]
      },
      {
        "id": "MedicationDispense.extension:recorded",
        "path": "MedicationDispense.extension",
        "sliceName": "recorded",
        "comment": "HIQA EP 6.2 Date and time of issuing the dispense record (Mandatory 1..1); 1..1 inherited from HL7 Europe MPD.",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.extension:receiverRelatedPerson",
        "path": "MedicationDispense.extension",
        "sliceName": "receiverRelatedPerson",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Extension",
            "profile": [
              "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-dispense-receiver-related-person"
            ]
          }
        ]
      },
      {
        "id": "MedicationDispense.identifier",
        "path": "MedicationDispense.identifier",
        "comment": "HIQA EP 6.1 Dispensation identifier (Required 0..*). IE Core requires at least one.",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.status",
        "path": "MedicationDispense.status",
        "comment": "HIQA EP 6.3.1 Dispensation status (Mandatory). A non-dispensation uses declined or stopped with a reason (invariant ie-md-status-1).",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.statusReason[x]",
        "path": "MedicationDispense.statusReason[x]",
        "comment": "HIQA EP 6.3.2 Dispensation status reason (Optional): coded (6.3.2.1) or free text (6.3.2.2, in statusReasonCodeableConcept.text). IE Core requires a reason for a non-dispensation (safety: the prescriber needs to know why).",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.medication[x]",
        "path": "MedicationDispense.medication[x]",
        "comment": "HIQA EP 6.6 Dispensed medication (Mandatory 1..1); see Section 4.",
        "mustSupport": true,
        "binding": {
          "strength": "extensible",
          "valueSet": "https://hl7-ie.github.io/ie-core/fhir/ie/core/ValueSet/ie-core-medication-codes"
        }
      },
      {
        "id": "MedicationDispense.subject",
        "path": "MedicationDispense.subject",
        "min": 1,
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-patient-eprescription"
            ]
          }
        ],
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.performer",
        "path": "MedicationDispense.performer",
        "comment": "HIQA EP Section 2 (dispenser and pharmacy). Dispensers are registered pharmacists or registered pharmaceutical assistants.",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.performer.actor",
        "path": "MedicationDispense.performer.actor",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-practitioner",
              "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-practitionerrole",
              "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-organization"
            ]
          }
        ],
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.authorizingPrescription",
        "path": "MedicationDispense.authorizingPrescription",
        "comment": "HIQA EP 6.5 Prescription item identifier with related request (Required 0..1). IE Core requires exactly one (stricter than HIQA, OI-012): this profile covers dispensing against an electronic prescription; emergency supply uses the base IECoreMedicationDispense.",
        "min": 1,
        "max": "1",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://hl7-ie.github.io/ie-core/fhir/ie/core/StructureDefinition/ie-core-medicationrequest-eprescription"
            ]
          }
        ],
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.quantity",
        "path": "MedicationDispense.quantity",
        "comment": "HIQA EP 6.7 Dispensed quantity (Mandatory 1..1).",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.whenHandedOver",
        "path": "MedicationDispense.whenHandedOver",
        "comment": "HIQA EP 6.8 Date of dispensation (Mandatory) and 6.9 Time of dispensation (Required). Required when the status is completed (invariant ie-md-handover-1).",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.receiver",
        "path": "MedicationDispense.receiver",
        "comment": "HIQA EP 6.4 Receiver (Optional): the patient (6.4.1) or a health practitioner (6.4.2). A related person (6.4.3) goes in extension[receiverRelatedPerson]."
      },
      {
        "id": "MedicationDispense.note",
        "path": "MedicationDispense.note",
        "comment": "HIQA EP 6.12 Additional information (Optional)."
      },
      {
        "id": "MedicationDispense.dosageInstruction",
        "path": "MedicationDispense.dosageInstruction",
        "comment": "HIQA EP 6.11 Dosage instructions (Required); see Section 5.",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.dosageInstruction.text",
        "path": "MedicationDispense.dosageInstruction.text",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.substitution",
        "path": "MedicationDispense.substitution",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.substitution.wasSubstituted",
        "path": "MedicationDispense.substitution.wasSubstituted",
        "comment": "HIQA EP 6.10 Substitution occurred (Optional).",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.substitution.type",
        "path": "MedicationDispense.substitution.type",
        "mustSupport": true
      },
      {
        "id": "MedicationDispense.substitution.reason",
        "path": "MedicationDispense.substitution.reason",
        "mustSupport": true
      }
    ]
  }
}