FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/nl-core-VisualAcuity

Packagenictiz.fhir.nl.r4.nl-core
TypeStructureDefinition
Idnl-core-VisualAcuity
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=nictiz.fhir.nl.r4.nl-core@0.12.0-beta.1&canonical=http://nictiz.nl/fhir/StructureDefinition/nl-core-VisualAcuity
URLhttp://nictiz.nl/fhir/StructureDefinition/nl-core-VisualAcuity
Statusdraft
NameNlcoreVisualAcuity
Titlenl core VisualAcuity
Realmnl
DescriptionVisual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish.
PurposeA derived profile from [zib-VisualAcuity](http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity) to provide a version better suited for implementation purposes. This profile augments the base profile with elements found in the various use cases that have adopted the zib.
CopyrightCopyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.
TypeObservation
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
nl-core-AnatomicalLocationnl core AnatomicalLocation
nl-core-Patientnl core Patient
nl-core-VisualAcuity.VisualAcuityMeasurementDevicenl core VisualAcuity.VisualAcuityMeasurementDevice
zib-VisualAcuityzib VisualAcuity

Narrative

Note: links and images are rebased to the (stated) source

No narrative is provided for definitional resources. A human-readable rendering can be found in the implementation guide(s) where this resource is used.

Source

{
  "resourceType": "StructureDefinition",
  "id": "nl-core-VisualAcuity",
  "text": {
    "status": "empty",
    "div": "<!-- snip (see above) -->"
  },
  "url": "http://nictiz.nl/fhir/StructureDefinition/nl-core-VisualAcuity",
  "name": "NlcoreVisualAcuity",
  "title": "nl core VisualAcuity",
  "status": "draft",
  "publisher": "Nictiz",
  "contact": [
    {
      "name": "Nictiz",
      "telecom": [
        {
          "system": "url",
          "value": "https://www.nictiz.nl",
          "use": "work"
        }
      ]
    }
  ],
  "description": "Visual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish.",
  "purpose": "A derived profile from [zib-VisualAcuity](http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity) to provide a version better suited for implementation purposes. This profile augments the base profile with elements found in the various use cases that have adopted the zib.",
  "copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
  "fhirVersion": "4.0.1",
  "mapping": [
    {
      "identity": "zib-visualacuity-v1.0-2020EN",
      "uri": "https://zibs.nl/wiki/VisualAcuity-v1.0(2020EN)",
      "name": "zib VisualAcuity-v1.0(2020EN)"
    }
  ],
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation",
        "path": "Observation",
        "alias": [
          "nl-core-VisualAcuity"
        ]
      },
      {
        "id": "Observation.subject",
        "path": "Observation.subject",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "http://hl7.org/fhir/StructureDefinition/Patient",
              "http://hl7.org/fhir/StructureDefinition/Group",
              "http://hl7.org/fhir/StructureDefinition/Device",
              "http://hl7.org/fhir/StructureDefinition/Location",
              "http://nictiz.nl/fhir/StructureDefinition/nl-core-Patient"
            ]
          }
        ]
      },
      {
        "id": "Observation.bodySite",
        "path": "Observation.bodySite",
        "type": [
          {
            "code": "CodeableConcept",
            "profile": [
              "http://nictiz.nl/fhir/StructureDefinition/nl-core-AnatomicalLocation"
            ]
          }
        ]
      },
      {
        "id": "Observation.device",
        "path": "Observation.device",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "http://hl7.org/fhir/StructureDefinition/Device",
              "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
              "http://nictiz.nl/fhir/StructureDefinition/nl-core-VisualAcuity.VisualAcuityMeasurementDevice"
            ]
          }
        ]
      }
    ]
  }
}