| Package | nictiz.fhir.nl.r4.nl-core |
| Resource Type | StructureDefinition |
| Id | nl-core-VisualAcuity |
| FHIR Version | R4 |
| Source | https://simplifier.net/resolve?scope=nictiz.fhir.nl.r4.nl-core@0.12.0-beta.1&canonical=http://nictiz.nl/fhir/StructureDefinition/nl-core-VisualAcuity |
| URL | http://nictiz.nl/fhir/StructureDefinition/nl-core-VisualAcuity |
| Status | draft |
| Name | NlcoreVisualAcuity |
| Title | nl core VisualAcuity |
| Realm | nl |
| Description | Visual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish. |
| Purpose | A derived profile from [zib-VisualAcuity](http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity) to provide a version better suited for implementation purposes. This profile augments the base profile with elements found in the various use cases that have adopted the zib. |
| Copyright | Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise. |
| Type | Observation |
| Kind | resource |
No resources found
| StructureDefinition | |
| nl-core-AnatomicalLocation | nl core AnatomicalLocation |
| nl-core-Patient | nl core Patient |
| nl-core-VisualAcuity.VisualAcuityMeasurementDevice | nl core VisualAcuity.VisualAcuityMeasurementDevice |
| zib-VisualAcuity | zib VisualAcuity |
Note: links and images are rebased to the (stated) source
{
"resourceType": "StructureDefinition",
"id": "nl-core-VisualAcuity",
"text": {
"status": "empty",
"div": "<!-- snip (see above) -->"
},
"url": "http://nictiz.nl/fhir/StructureDefinition/nl-core-VisualAcuity",
"name": "NlcoreVisualAcuity",
"title": "nl core VisualAcuity",
"status": "draft",
"publisher": "Nictiz",
"contact": [
{
"name": "Nictiz",
"telecom": [
{
"system": "url",
"value": "https://www.nictiz.nl",
"use": "work"
}
]
}
],
"description": "Visual acuity is a measurement of sharpness of vision. It is a measure of the smallest details that someone can still distinguish.",
"purpose": "A derived profile from [zib-VisualAcuity](http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity) to provide a version better suited for implementation purposes. This profile augments the base profile with elements found in the various use cases that have adopted the zib.",
"copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
"fhirVersion": "4.0.1",
"mapping": [
{
"identity": "zib-visualacuity-v1.0-2020EN",
"uri": "https://zibs.nl/wiki/VisualAcuity-v1.0(2020EN)",
"name": "zib VisualAcuity-v1.0(2020EN)"
}
],
"kind": "resource",
"abstract": false,
"type": "Observation",
"baseDefinition": "http://nictiz.nl/fhir/StructureDefinition/zib-VisualAcuity",
"derivation": "constraint",
"differential": {
"element": [
{
"id": "Observation",
"path": "Observation",
"alias": [
"nl-core-VisualAcuity"
]
},
{
"id": "Observation.subject",
"path": "Observation.subject",
"type": [
{
"code": "Reference",
"targetProfile": [
"http://hl7.org/fhir/StructureDefinition/Patient",
"http://hl7.org/fhir/StructureDefinition/Group",
"http://hl7.org/fhir/StructureDefinition/Device",
"http://hl7.org/fhir/StructureDefinition/Location",
"http://nictiz.nl/fhir/StructureDefinition/nl-core-Patient"
]
}
]
},
{
"id": "Observation.bodySite",
"path": "Observation.bodySite",
"type": [
{
"code": "CodeableConcept",
"profile": [
"http://nictiz.nl/fhir/StructureDefinition/nl-core-AnatomicalLocation"
]
}
]
},
{
"id": "Observation.device",
"path": "Observation.device",
"type": [
{
"code": "Reference",
"targetProfile": [
"http://hl7.org/fhir/StructureDefinition/Device",
"http://hl7.org/fhir/StructureDefinition/DeviceMetric",
"http://nictiz.nl/fhir/StructureDefinition/nl-core-VisualAcuity.VisualAcuityMeasurementDevice"
]
}
]
}
]
}
}