FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/nl-core-Refraction

Packagenictiz.fhir.nl.r4.nl-core
TypeStructureDefinition
Idnl-core-Refraction
FHIR VersionR4
Sourcehttps://simplifier.net/resolve?scope=nictiz.fhir.nl.r4.nl-core@0.12.0-beta.1&canonical=http://nictiz.nl/fhir/StructureDefinition/nl-core-Refraction
URLhttp://nictiz.nl/fhir/StructureDefinition/nl-core-Refraction
Statusdraft
NameNlcoreRefraction
Titlenl core Refraction
Realmnl
DescriptionThe refraction measurement is a measurement with which the refractive error of the eye is determined. During the refraction measurement, the necessary correction is established: the spherical power (in diopters), the cylindrical power (in diopters), the axis direction (in degrees) for any cylindrical correction, the prism (in prism diopters) and any additional power of the reading area (in diopters), the so-called reading addition.
PurposeA derived profile from [zib-Refraction](http://nictiz.nl/fhir/StructureDefinition/zib-Refraction) to provide a version better suited for implementation purposes. This profile augments the base profile with elements found in the various use cases that have adopted the zib.
CopyrightCopyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.
TypeObservation
Kindresource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
nl-core-AnatomicalLocationnl core AnatomicalLocation
nl-core-Patientnl core Patient
zib-Refractionzib Refraction

Narrative

Note: links and images are rebased to the (stated) source

No narrative is provided for definitional resources. A human-readable rendering can be found in the implementation guide(s) where this resource is used.

Source

{
  "resourceType": "StructureDefinition",
  "id": "nl-core-Refraction",
  "text": {
    "status": "empty",
    "div": "<!-- snip (see above) -->"
  },
  "url": "http://nictiz.nl/fhir/StructureDefinition/nl-core-Refraction",
  "name": "NlcoreRefraction",
  "title": "nl core Refraction",
  "status": "draft",
  "publisher": "Nictiz",
  "contact": [
    {
      "name": "Nictiz",
      "telecom": [
        {
          "system": "url",
          "value": "https://www.nictiz.nl",
          "use": "work"
        }
      ]
    }
  ],
  "description": "The refraction measurement is a measurement with which the refractive error of the eye is determined. During the refraction measurement, the necessary correction is established: the spherical power (in diopters), the cylindrical power (in diopters), the axis direction (in degrees) for any cylindrical correction, the prism (in prism diopters) and any additional power of the reading area (in diopters), the so-called reading addition.",
  "purpose": "A derived profile from [zib-Refraction](http://nictiz.nl/fhir/StructureDefinition/zib-Refraction) to provide a version better suited for implementation purposes. This profile augments the base profile with elements found in the various use cases that have adopted the zib.",
  "copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
  "fhirVersion": "4.0.1",
  "mapping": [
    {
      "identity": "zib-refraction-v1.0-2020EN",
      "uri": "https://zibs.nl/wiki/Refraction-v1.0(2020EN)",
      "name": "zib Refraction-v1.0(2020EN)"
    }
  ],
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "http://nictiz.nl/fhir/StructureDefinition/zib-Refraction",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation",
        "path": "Observation",
        "alias": [
          "nl-core-Refraction"
        ]
      },
      {
        "id": "Observation.subject",
        "path": "Observation.subject",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "http://hl7.org/fhir/StructureDefinition/Patient",
              "http://hl7.org/fhir/StructureDefinition/Group",
              "http://hl7.org/fhir/StructureDefinition/Device",
              "http://hl7.org/fhir/StructureDefinition/Location",
              "http://nictiz.nl/fhir/StructureDefinition/nl-core-Patient"
            ]
          }
        ]
      },
      {
        "id": "Observation.bodySite",
        "path": "Observation.bodySite",
        "type": [
          {
            "code": "CodeableConcept",
            "profile": [
              "http://nictiz.nl/fhir/StructureDefinition/nl-core-AnatomicalLocation"
            ]
          }
        ]
      }
    ]
  }
}