Package | navify.fhir.r5.rdc |
Resource Type | StructureDefinition |
Id | ext-CalibrationStatus |
FHIR Version | R5 |
Source | https://simplifier.net/resolve?scope=navify.fhir.r5.rdc@1.0.0&canonical=https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus |
URL | https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus |
Status | active |
Name | ExtCalibrationStatus |
Title | ext CalibrationStatus |
Description | This CalibrationStatus extension is used to capture the Calibration status of the CGM Device. The CGM value in the observation resource will be considered when extension CalibrationStatus = `calibrated` if the extension: CalibrationStatus = `uncalibrated` then it will be not considered as a valid entry. |
Copyright | Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise. |
Type | Extension |
Kind | complex-type |
StructureDefinition | |
rdc-Observation-CGM | RDC Obseration CGM |
No resources found
No extension usage examples found
No narrative content found in resource
{ "resourceType": "StructureDefinition", "id": "ext-CalibrationStatus", "url": "https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus", "name": "ExtCalibrationStatus", "title": "ext CalibrationStatus", "status": "active", "publisher": "F. Hoffmann-La Roche AG", "description": "This CalibrationStatus extension is used to capture the Calibration status of the CGM Device.\r\n\r\nThe CGM value in the observation resource will be considered when extension CalibrationStatus = `calibrated` if the extension: CalibrationStatus = `uncalibrated` then it will be not considered as a valid entry.", "copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.", "fhirVersion": "5.0.0", "kind": "complex-type", "abstract": false, "context": [ { "type": "element", "expression": "Observation" } ], "type": "Extension", "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension", "derivation": "constraint", "differential": { "element": [ { "id": "Extension", "path": "Extension", "max": "1" }, { "id": "Extension.url", "path": "Extension.url", "fixedUri": "https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus" }, { "id": "Extension.value[x]", "path": "Extension.value[x]", "type": [ { "code": "string" } ] } ] } }