FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagemedcom.fhir.dk.xdsmetadata
Resource TypeConceptMap
IdConceptMap-MedComConceptMapOIDToCodeSystemReference.json
FHIR VersionR4
Sourcehttp://medcomfhir.dk/ig/xdsmetadata/2.0.0-trial-use-1/ConceptMap-MedComConceptMapOIDToCodeSystemReference.html
URLhttp://medcomfhir.dk/ig/xdsmetadata/ConceptMap/MedComConceptMapOIDToCodeSystemReference
Version2.0.0-trial-use-1
Statusdraft
Date2026-05-29T11:30:26+00:00
NameMedComConceptMapOIDToCodeSystemReference
TitleOID to CodeSystem Reference ConceptMap
Realmdk
DescriptionMaps OIDs to their corresponding FHIR CodeSystem references where available.

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap MedComConceptMapOIDToCodeSystemReference

Mapping from (not specified) to (not specified)


Group 1 Mapping from oid-registry to XDS-Metadata-CodeSystems

Source Concept DetailsRelationshipTarget Concept DetailsComment
Codes from oid-registryCodes from XDS-Metadata-CodeSystems
2.16.840.1.113883.6.96SCTis equivalent tohttp://snomed.info/sct|http://snomed.info/sct/554471000005108/version/20260331http://snomed.info/sct|http://snomed.info/sct/554471000005108/version/20260331Latest SNOMED CT Danish Edition as of 2026-03-31 is used.
2.16.840.1.113883.6.1LOINCis equivalent tohttp://loinc.orghttp://loinc.org
2.16.840.1.113883.5.79mediaTypeis equivalent tourn:ietf:bcp:13urn:ietf:bcp:13
2.16.840.1.113883.6.121ieft3066is equivalent tourn:ietf:bcp:47urn:ietf:bcp:47
2.16.840.1.113883.5.25Confidentialityis equivalent tohttp://npu-terminology.orghttp://npu-terminology.org
1.2.208.176.2.4SKS(not mapped)No CodeSystem reference provided in the source table.
1.2.208.176.7.3.1schema-list(not mapped)No CodeSystem reference provided in the source table.
1.2.208.176.8.1iheis equivalent tohttp://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-xds-homeCommunityId-CShttp://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-xds-homeCommunityId-CS
1.2.208.184.100.9classcodeis equivalent tohttp://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-xds-classcode-CShttp://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-xds-classcode-CS
1.2.208.184.100.1message-codesis equivalent tohttp://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-ihe-typecode-CShttp://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-ihe-typecode-CS
1.2.208.184.100.10formatcodeis equivalent tohttp://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-ihe-formatcode-CShttp://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-ihe-formatcode-CS

Source1

{
  "resourceType": "ConceptMap",
  "id": "MedComConceptMapOIDToCodeSystemReference",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "url": "http://medcomfhir.dk/ig/xdsmetadata/ConceptMap/MedComConceptMapOIDToCodeSystemReference",
  "version": "2.0.0-trial-use-1",
  "name": "MedComConceptMapOIDToCodeSystemReference",
  "title": "OID to CodeSystem Reference ConceptMap",
  "status": "draft",
  "experimental": false,
  "date": "2026-05-29T11:30:26+00:00",
  "publisher": "MedCom",
  "contact": [
    {
      "name": "MedCom",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.medcom.dk"
        }
      ]
    }
  ],
  "description": "Maps OIDs to their corresponding FHIR CodeSystem references where available.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "urn:iso:std:iso:3166",
          "code": "DK",
          "display": "Denmark"
        }
      ]
    }
  ],
  "group": [
    {
      "source": "oid-registry",
      "target": "XDS-Metadata-CodeSystems",
      "element": [
        {
          "code": "2.16.840.1.113883.6.96",
          "display": "SCT",
          "target": [
            {
              "code": "http://snomed.info/sct|http://snomed.info/sct/554471000005108/version/20260331",
              "display": "http://snomed.info/sct|http://snomed.info/sct/554471000005108/version/20260331",
              "equivalence": "equivalent",
              "comment": "Latest SNOMED CT Danish Edition as of 2026-03-31 is used."
            }
          ]
        },
        {
          "code": "2.16.840.1.113883.6.1",
          "display": "LOINC",
          "target": [
            {
              "code": "http://loinc.org",
              "display": "http://loinc.org",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "2.16.840.1.113883.5.79",
          "display": "mediaType",
          "target": [
            {
              "code": "urn:ietf:bcp:13",
              "display": "urn:ietf:bcp:13",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "2.16.840.1.113883.6.121",
          "display": "ieft3066",
          "target": [
            {
              "code": "urn:ietf:bcp:47",
              "display": "urn:ietf:bcp:47",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "2.16.840.1.113883.5.25",
          "display": "Confidentiality",
          "target": [
            {
              "code": "http://npu-terminology.org",
              "display": "http://npu-terminology.org",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "1.2.208.176.2.4",
          "display": "SKS",
          "target": [
            {
              "equivalence": "unmatched",
              "comment": "No CodeSystem reference provided in the source table."
            }
          ]
        },
        {
          "code": "1.2.208.176.2.1",
          "display": "NPU"
        },
        {
          "code": "1.2.208.176.7.3.1",
          "display": "schema-list",
          "target": [
            {
              "equivalence": "unmatched",
              "comment": "No CodeSystem reference provided in the source table."
            }
          ]
        },
        {
          "code": "1.2.208.176.8.1",
          "display": "ihe",
          "target": [
            {
              "code": "http://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-xds-homeCommunityId-CS",
              "display": "http://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-xds-homeCommunityId-CS",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "1.2.208.184.100.9",
          "display": "classcode",
          "target": [
            {
              "code": "http://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-xds-classcode-CS",
              "display": "http://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-xds-classcode-CS",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "1.2.208.184.100.1",
          "display": "message-codes",
          "target": [
            {
              "code": "http://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-ihe-typecode-CS",
              "display": "http://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-ihe-typecode-CS",
              "equivalence": "equivalent"
            }
          ]
        },
        {
          "code": "1.2.208.184.100.10",
          "display": "formatcode",
          "target": [
            {
              "code": "http://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-ihe-formatcode-CS",
              "display": "http://medcomfhir.dk/ig/xdsmetadata/CodeSystem/MedCom-ihe-formatcode-CS",
              "equivalence": "equivalent"
            }
          ]
        }
      ]
    }
  ]
}