FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagelt.hl7.fhir.vitalsigns
Resource TypeValueSet
IdValueSet-numeric-result-interpretation-non-panic.json
FHIR VersionR5
Sourcehttps://hl7.lt/fhir/vitalsigns/0.0.1/ValueSet-numeric-result-interpretation-non-panic.html
URLhttps://hl7.lt/fhir/vitalsigns/ValueSet/numeric-result-interpretation-non-panic
Version1.0.0
Statusactive
Date2025-11-19T15:54:38+02:00
NameNumericResultInterpretationNonPanic
TitleNumeric Result Interpretation without panic values, value set
DescriptionThe HL7 V3:ObservationInterpretation code set (OID: 2.16.840.1.113883.5.83) that describes interpretations associated with a measured value, constrained to terms that are not those associated with 'panic' terms.
CopyrightLogica Health, all rights reserved Creative Commons License

Resources that use this resource

StructureDefinition
lt.hl7.fhir.vitalsigns#0.0.1bmiBody Mass Index
lt.hl7.fhir.vitalsigns#0.0.1body-heightBody Height
lt.hl7.fhir.vitalsigns#0.0.1body-weightBody Weight
lt.hl7.fhir.vitalsigns#0.0.1head-circumferenceHead Circumference
lt.hl7.fhir.vitalsigns#0.0.1waist-circumferenceWaist Circumference

Resources that this resource uses

CodeSystem
hl7.terminology#currentv3-ObservationInterpretationObservationInterpretation

Narrative

Note: links and images are rebased to the (stated) source


English


Generated Narrative: ValueSet numeric-result-interpretation-non-panic

Language: en

  • Include these codes as defined in http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation version 📦3.0.0
    CodeDisplayDefinition
    AAbnormalThe result or observation value is outside the reference range or expected norm (as defined for the respective test procedure).

    \[Note: Typically applies to non-numeric results.\]
    HHigher Than NormalThe result for a quantitative observation is above the upper limit of the reference range (as defined for the respective test procedure).

    Synonym: Above high normal
    LLower Than NormalThe result for a quantitative observation is below the lower limit of the reference range (as defined for the respective test procedure).

    Synonym: Below low normal

Lithuanian


Generated Narrative: ValueSet numeric-result-interpretation-non-panic

Language: en

  • Include these codes as defined in http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation version 📦3.0.0
    CodeDisplayDefinition
    AAbnormalThe result or observation value is outside the reference range or expected norm (as defined for the respective test procedure).

    \[Note: Typically applies to non-numeric results.\]
    HHigher Than NormalThe result for a quantitative observation is above the upper limit of the reference range (as defined for the respective test procedure).

    Synonym: Above high normal
    LLower Than NormalThe result for a quantitative observation is below the lower limit of the reference range (as defined for the respective test procedure).

    Synonym: Below low normal

Source1

{
  "resourceType": "ValueSet",
  "id": "numeric-result-interpretation-non-panic",
  "language": "en",
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "url": "https://hl7.lt/fhir/vitalsigns/ValueSet/numeric-result-interpretation-non-panic",
  "version": "1.0.0",
  "name": "NumericResultInterpretationNonPanic",
  "title": "Numeric Result Interpretation without panic values, value set",
  "status": "active",
  "experimental": false,
  "date": "2025-11-19T15:54:38+02:00",
  "publisher": "Lithuanian Medical Library",
  "_publisher": {
    "extension": [
      {
        "extension": [
          {
            "url": "lang",
            "valueCode": "lt"
          },
          {
            "url": "content",
            "valueString": "Lietuvos medicinos biblioteka"
          }
        ],
        "url": "http://hl7.org/fhir/StructureDefinition/translation"
      }
    ]
  },
  "contact": [
    {
      "name": "Lithuanian Medical Library",
      "telecom": [
        {
          "system": "url",
          "value": "https://medicinosnk.lt"
        },
        {
          "system": "email",
          "value": "info@medicinosnk.lt"
        }
      ]
    }
  ],
  "description": "The HL7 V3:ObservationInterpretation code set (OID: 2.16.840.1.113883.5.83) that describes interpretations associated with a measured value, constrained to terms that are not those associated with 'panic' terms.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "urn:iso:std:iso:3166",
          "code": "LT"
        }
      ]
    }
  ],
  "copyright": "Logica Health, all rights reserved Creative Commons License",
  "compose": {
    "include": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
        "concept": [
          {
            "code": "A",
            "display": "Abnormal"
          },
          {
            "code": "H",
            "display": "Higher Than Normal"
          },
          {
            "code": "L",
            "display": "Lower Than Normal"
          }
        ]
      }
    ]
  }
}