FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: StructureDefinition/ihe-ext-medication-unitofpresentation

Packageihe.pharm.mpd
TypeStructureDefinition
Idihe-ext-medication-unitofpresentation
FHIR VersionR5
Sourcehttps://profiles.ihe.net/PHARM/MPD/https://build.fhir.org/ig/IHE/pharm-mpd/StructureDefinition-ihe-ext-medication-unitofpresentation.html
URLhttps://profiles.ihe.net/PHARM/MPD/StructureDefinition/ihe-ext-medication-unitofpresentation
Version1.0.0-comment-2
Statusactive
Date2025-06-09T07:25:27+00:00
NameMedicationUnitOfPresentation
TitleMedication - Unit of presentation
Realmuv
Authorityihe
DescriptionUnit of presentation, typically describing the smallest countable package item (e.g tablet, vial, ampoule, etc). Unit of presentation is also often used in describing pack size and the denominator of strength. If the size of presentation unit is relevant, it should be described in sizeOfItem extension.
CopyrightIHE http://www.ihe.net/Governance/#Intellectual_Property
TypeExtension
Kindcomplex-type

Resources that use this resource

StructureDefinition
Medication-eu-epsMedication (EPS)
Medication-eu-mpdMedication: MPD
IHEMedicationIHE Medication
medication-eu-hdrMedication (HDR)

Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: StructureDefinition ihe-ext-medication-unitofpresentation

NameFlagsCard.TypeDescription & Constraintsdoco
.. Extension 0..*ExtensionMedication - Unit of presentation
... extension 0..0
... url 1..1uri"https://profiles.ihe.net/PHARM/MPD/StructureDefinition/ihe-ext-medication-unitofpresentation"
... value[x] 1..1CodeableConceptValue of extension
Binding: UnitOfPresentation (example)

doco Documentation for this format

Source

{
  "resourceType": "StructureDefinition",
  "id": "ihe-ext-medication-unitofpresentation",
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-type-characteristics",
      "valueCode": "can-bind"
    }
  ],
  "url": "https://profiles.ihe.net/PHARM/MPD/StructureDefinition/ihe-ext-medication-unitofpresentation",
  "version": "1.0.0-comment-2",
  "name": "MedicationUnitOfPresentation",
  "title": "Medication - Unit of presentation",
  "status": "active",
  "date": "2025-06-09T07:25:27+00:00",
  "publisher": "Integrating the Healthcare Enterprise (IHE)",
  "contact": [
    {
      "name": "Integrating the Healthcare Enterprise (IHE)",
      "telecom": [
        {
          "system": "url",
          "value": "http://ihe.net"
        },
        {
          "system": "email",
          "value": "secretary@ihe.net"
        }
      ]
    },
    {
      "name": "José Costa Teixeira",
      "telecom": [
        {
          "system": "email",
          "value": "jose.a.teixeira@gmail.com",
          "use": "work"
        }
      ]
    }
  ],
  "description": "Unit of presentation, typically describing the smallest countable package item (e.g tablet, vial, ampoule, etc). Unit of presentation is also often used in describing pack size and the denominator of strength. If the size of presentation unit is relevant, it should be described in sizeOfItem extension.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001"
        }
      ]
    }
  ],
  "copyright": "IHE http://www.ihe.net/Governance/#Intellectual_Property",
  "fhirVersion": "5.0.0",
  "mapping": [
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    }
  ],
  "kind": "complex-type",
  "abstract": false,
  "context": [
    {
      "type": "element",
      "expression": "Medication"
    }
  ],
  "type": "Extension",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension",
  "derivation": "constraint",
  "snapshot": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/tools/StructureDefinition/snapshot-base-version",
        "valueString": "5.0.0"
      }
    ],
    "element": [
      {
        "id": "Extension",
        "path": "Extension",
        "short": "Medication - Unit of presentation",
        "definition": "Unit of presentation, typically describing the smallest countable package item (e.g tablet, vial, ampoule, etc). Unit of presentation is also often used in describing pack size and the denominator of strength. If the size of presentation unit is relevant, it should be described in sizeOfItem extension.",
        "min": 0,
        "max": "*",
        "base": {
          "path": "Extension",
          "min": 0,
          "max": "*"
        },
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "isModifier": false
      },
      {
        "id": "Extension.id",
        "path": "Extension.id",
        "representation": [
          "xmlAttr"
        ],
        "short": "Unique id for inter-element referencing",
        "definition": "Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.",
        "min": 0,
        "max": "1",
        "base": {
          "path": "Element.id",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fhir-type",
                "valueUrl": "id"
              }
            ],
            "code": "http://hl7.org/fhirpath/System.String"
          }
        ],
        "condition": [
          "ele-1"
        ],
        "isModifier": false,
        "isSummary": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "n/a"
          }
        ]
      },
      {
        "id": "Extension.extension",
        "path": "Extension.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "description": "Extensions are always sliced by (at least) url",
          "rules": "open"
        },
        "short": "Extension",
        "definition": "An Extension",
        "min": 0,
        "max": "0",
        "base": {
          "path": "Element.extension",
          "min": 0,
          "max": "*"
        },
        "type": [
          {
            "code": "Extension"
          }
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          },
          {
            "key": "ext-1",
            "severity": "error",
            "human": "Must have either extensions or value[x], not both",
            "expression": "extension.exists() != value.exists()",
            "source": "http://hl7.org/fhir/StructureDefinition/Extension"
          }
        ],
        "isModifier": false,
        "isSummary": false
      },
      {
        "id": "Extension.url",
        "path": "Extension.url",
        "representation": [
          "xmlAttr"
        ],
        "short": "identifies the meaning of the extension",
        "definition": "Source of the definition for the extension code - a logical name or a URL.",
        "comment": "The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension.",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Extension.url",
          "min": 1,
          "max": "1"
        },
        "type": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fhir-type",
                "valueUrl": "uri"
              }
            ],
            "code": "http://hl7.org/fhirpath/System.String"
          }
        ],
        "fixedUri": "https://profiles.ihe.net/PHARM/MPD/StructureDefinition/ihe-ext-medication-unitofpresentation",
        "isModifier": false,
        "isSummary": false,
        "mapping": [
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      },
      {
        "id": "Extension.value[x]",
        "path": "Extension.value[x]",
        "short": "Value of extension",
        "definition": "Value of extension - must be one of a constrained set of the data types (see [Extensibility](http://hl7.org/fhir/R5/extensibility.html) for a list).",
        "min": 1,
        "max": "1",
        "base": {
          "path": "Extension.value[x]",
          "min": 0,
          "max": "1"
        },
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "condition": [
          "ext-1"
        ],
        "constraint": [
          {
            "key": "ele-1",
            "severity": "error",
            "human": "All FHIR elements must have a @value or children",
            "expression": "hasValue() or (children().count() > id.count())",
            "source": "http://hl7.org/fhir/StructureDefinition/Element"
          }
        ],
        "isModifier": false,
        "isSummary": false,
        "binding": {
          "strength": "example",
          "valueSet": "http://hl7.org/fhir/ValueSet/unit-of-presentation"
        },
        "mapping": [
          {
            "identity": "rim",
            "map": "N/A"
          }
        ]
      }
    ]
  },
  "differential": {
    "element": [
      {
        "id": "Extension",
        "path": "Extension",
        "short": "Medication - Unit of presentation",
        "definition": "Unit of presentation, typically describing the smallest countable package item (e.g tablet, vial, ampoule, etc). Unit of presentation is also often used in describing pack size and the denominator of strength. If the size of presentation unit is relevant, it should be described in sizeOfItem extension."
      },
      {
        "id": "Extension.extension",
        "path": "Extension.extension",
        "max": "0"
      },
      {
        "id": "Extension.url",
        "path": "Extension.url",
        "fixedUri": "https://profiles.ihe.net/PHARM/MPD/StructureDefinition/ihe-ext-medication-unitofpresentation"
      },
      {
        "id": "Extension.value[x]",
        "path": "Extension.value[x]",
        "min": 1,
        "type": [
          {
            "code": "CodeableConcept"
          }
        ],
        "binding": {
          "strength": "example",
          "valueSet": "http://hl7.org/fhir/ValueSet/unit-of-presentation"
        }
      }
    ]
  }
}