FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packageig-encounter-episode
Resource TypeBundle
Idvalidation-oo.json
FHIR VersionR5

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

No narrative content found in resource


Source1

{
  "resourceType": "Bundle",
  "type": "collection",
  "timestamp": "2026-02-03T07:15:14.740+00:00",
  "entry": [
    {
      "fullUrl": "https://fhir.ee/encounter-episode/OperationOutcome/ImplementationGuide-ig-encounter-episode",
      "resource": {
        "resourceType": "OperationOutcome",
        "id": "ImplementationGuide-ig-encounter-episode",
        "issue": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 1982
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "IG_DEPENDENCY_VERSION_WARNING_OLD"
              }
            ],
            "severity": "warning",
            "code": "business-rule",
            "details": {
              "text": "The ImplementationGuide uses package ee.fhir.base#1.2.1 released on 2025-09-12, but the most recent appropriate version is 2.0.0. This reference is getting old and the more recent version should be considered"
            },
            "expression": [
              "ImplementationGuide/ig-encounter-episode: ImplementationGuide.dependsOn[2]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 2107
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "IG_DEPENDENCY_VERSION_WARNING_OLD"
              }
            ],
            "severity": "warning",
            "code": "business-rule",
            "details": {
              "text": "The ImplementationGuide uses package ee.fhir.mpi#1.1.1 released on 2024-07-30, but the most recent appropriate version is 1.5.0. This reference is getting old and the more recent version should be considered"
            },
            "expression": [
              "ImplementationGuide/ig-encounter-episode: ImplementationGuide.dependsOn[3]"
            ]
          }
        ]
      }
    },
    {
      "fullUrl": "https://fhir.ee/encounter-episode/OperationOutcome/StructureDefinition-ee-tis-encounter",
      "resource": {
        "resourceType": "OperationOutcome",
        "id": "StructureDefinition-ee-tis-encounter",
        "issue": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 29637
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-encounter' to 'https://fhir.ee/base/StructureDefinition/ee-encounter|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.baseDefinition"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 41320
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-mode-of-arrival'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-mode-of-arrival' to 'https://fhir.ee/base/StructureDefinition/ee-mode-of-arrival|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[8].type[0].profile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 42235
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/encounter-associatedEncounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0-ballot-tc1', found versions: 5.1.0 (from hl7.fhir.uv.extensions.r5#5.1.0), 5.2.0 (from hl7.fhir.uv.extensions.r5#5.2.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions#current). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/encounter-associatedEncounter' to 'http://hl7.org/fhir/StructureDefinition/encounter-associatedEncounter|5.3.0-ballot-tc1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[9].type[0].profile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 50895
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-healthcare-service'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-healthcare-service' to 'https://fhir.ee/base/StructureDefinition/ee-healthcare-service|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[16].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 52683
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-patient' to 'https://fhir.ee/base/StructureDefinition/ee-patient|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[17].type[0].targetProfile[1]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 55540
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-episode-of-care'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-episode-of-care' to 'https://fhir.ee/base/StructureDefinition/ee-episode-of-care|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[19].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 58413
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-encounter'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-encounter' to 'https://fhir.ee/base/StructureDefinition/ee-encounter|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[22].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 59579
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-organization' to 'https://fhir.ee/base/StructureDefinition/ee-organization|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[23].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 70042
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-practitioner' to 'https://fhir.ee/base/StructureDefinition/ee-practitioner|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[30].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 70103
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-related-person'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-related-person' to 'https://fhir.ee/base/StructureDefinition/ee-related-person|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[30].type[0].targetProfile[1]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 70167
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role' to 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[30].type[0].targetProfile[2]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 83700
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-observation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-observation' to 'https://fhir.ee/base/StructureDefinition/ee-observation|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[42].type[0].targetProfile[2]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 104885
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-location'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-location' to 'https://fhir.ee/base/StructureDefinition/ee-location|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[58].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 104944
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-organization' to 'https://fhir.ee/base/StructureDefinition/ee-organization|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[58].type[0].targetProfile[1]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 107832
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-location'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-location' to 'https://fhir.ee/base/StructureDefinition/ee-location|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[61].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 107891
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-organization' to 'https://fhir.ee/base/StructureDefinition/ee-organization|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[61].type[0].targetProfile[1]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 115237
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-location'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-location' to 'https://fhir.ee/base/StructureDefinition/ee-location|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[67].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 119626
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-patient'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-patient' to 'https://fhir.ee/base/StructureDefinition/ee-patient|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.differential.element[4].type[0].targetProfile[1]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 119969
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-practitioner' to 'https://fhir.ee/base/StructureDefinition/ee-practitioner|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.differential.element[6].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 120030
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-related-person'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-related-person' to 'https://fhir.ee/base/StructureDefinition/ee-related-person|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.differential.element[6].type[0].targetProfile[1]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 120094
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role' to 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.differential.element[6].type[0].targetProfile[2]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "SD_ED_EXPERIMENTAL_BINDING"
              }
            ],
            "severity": "warning",
            "code": "business-rule",
            "details": {
              "text": "The definition for the element 'Encounter.status' binds to the value set 'http://hl7.org/fhir/ValueSet/encounter-status|5.0.0' which is experimental, but this structure is not labeled as experimental"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[12].binding"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "SD_ED_EXPERIMENTAL_BINDING"
              }
            ],
            "severity": "warning",
            "code": "business-rule",
            "details": {
              "text": "The definition for the element 'Encounter.reason.value' binds to the value set 'http://hl7.org/fhir/ValueSet/encounter-reason|5.0.0' which is experimental, but this structure is not labeled as experimental"
            },
            "expression": [
              "StructureDefinition/ee-tis-encounter: StructureDefinition.snapshot.element[42].binding"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "Publisher"
              }
            ],
            "severity": "warning",
            "code": "business-rule",
            "details": {
              "text": "The Implementation Guide contains no examples for this profile"
            },
            "expression": [
              "StructureDefinition.where(url = 'https://fhir.ee/encounter-episode/StructureDefinition/ee-tis-encounter')"
            ]
          }
        ]
      }
    },
    {
      "fullUrl": "https://fhir.ee/encounter-episode/OperationOutcome/StructureDefinition-ee-tis-eoc-or-encounter-reference",
      "resource": {
        "resourceType": "OperationOutcome",
        "id": "StructureDefinition-ee-tis-eoc-or-encounter-reference",
        "issue": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 9882
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.3.0-ballot-tc1', found versions: 5.1.0 (from hl7.fhir.uv.extensions.r5#5.1.0), 5.2.0 (from hl7.fhir.uv.extensions.r5#5.2.0), 5.3.0-ballot-tc1 (from hl7.fhir.uv.extensions#current). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo' to 'http://hl7.org/fhir/StructureDefinition/workflow-supportingInfo|5.3.0-ballot-tc1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-eoc-or-encounter-reference: StructureDefinition.baseDefinition"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "Publisher"
              }
            ],
            "severity": "warning",
            "code": "business-rule",
            "details": {
              "text": "The Implementation Guide contains no examples for this extension"
            },
            "expression": [
              "StructureDefinition.where(url = 'https://fhir.ee/encounter-episode/StructureDefinition/ee-tis-eoc-or-encounter-reference')"
            ]
          }
        ]
      }
    },
    {
      "fullUrl": "https://fhir.ee/encounter-episode/OperationOutcome/StructureDefinition-ee-tis-episode-of-care",
      "resource": {
        "resourceType": "OperationOutcome",
        "id": "StructureDefinition-ee-tis-episode-of-care",
        "issue": [
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 32307
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-episode-of-care'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-episode-of-care' to 'https://fhir.ee/base/StructureDefinition/ee-episode-of-care|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-episode-of-care: StructureDefinition.baseDefinition"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 65095
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-observation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-observation' to 'https://fhir.ee/base/StructureDefinition/ee-observation|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-episode-of-care: StructureDefinition.snapshot.element[24].type[0].targetProfile[2]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 65160
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-healthcare-service'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-healthcare-service' to 'https://fhir.ee/base/StructureDefinition/ee-healthcare-service|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-episode-of-care: StructureDefinition.snapshot.element[24].type[0].targetProfile[3]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 75312
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-organization'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-organization' to 'https://fhir.ee/base/StructureDefinition/ee-organization|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-episode-of-care: StructureDefinition.snapshot.element[32].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 76592
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "Type_Specific_Checks_DT_String_WS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "value should not start or finish with whitespace ' (ee Viide saatekirjale või suunamisele, mille alusel episood algatati.)'"
            },
            "expression": [
              "StructureDefinition/ee-tis-episode-of-care: StructureDefinition.snapshot.element[34].short"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 77632
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-practitioner'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-practitioner' to 'https://fhir.ee/base/StructureDefinition/ee-practitioner|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-episode-of-care: StructureDefinition.snapshot.element[35].type[0].targetProfile[0]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 77696
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "There are multiple different potential matches for the url 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '1.2.1', found versions: 1.1.1 (from ee.fhir.base#1.1.1), 1.2.1 (from ee.fhir.base#1.2.1). Suggested fix: change the canonical reference from 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role' to 'https://fhir.ee/base/StructureDefinition/ee-practitioner-role|1.2.1'"
            },
            "expression": [
              "StructureDefinition/ee-tis-episode-of-care: StructureDefinition.snapshot.element[35].type[0].targetProfile[1]"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-line",
                "valueInteger": 1
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-col",
                "valueInteger": 81772
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "InstanceValidator"
              },
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-message-id",
                "valueCode": "Type_Specific_Checks_DT_String_WS"
              }
            ],
            "severity": "warning",
            "code": "invalid",
            "details": {
              "text": "value should not start or finish with whitespace ' (ee Viide saatekirjale või suunamisele, mille alusel episood algatati.)'"
            },
            "expression": [
              "StructureDefinition/ee-tis-episode-of-care: StructureDefinition.differential.element[11].short"
            ]
          },
          {
            "extension": [
              {
                "url": "http://hl7.org/fhir/StructureDefinition/operationoutcome-issue-source",
                "valueString": "Publisher"
              }
            ],
            "severity": "warning",
            "code": "business-rule",
            "details": {
              "text": "The Implementation Guide contains no examples for this profile"
            },
            "expression": [
              "StructureDefinition.where(url = 'https://fhir.ee/encounter-episode/StructureDefinition/ee-tis-episode-of-care')"
            ]
          }
        ]
      }
    }
  ]
}