FHIR IG analytics| Package | hl7.v2.uv.terminology.v271 |
| Resource Type | CodeSystem |
| Id | CodeSystem-specimenRole.json |
| FHIR Version | R4 |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole{
"resourceType": "CodeSystem",
"id": "specimenRole",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://terminology.hl7.org/v2plusvocab/StructureDefinition/codesystem-v2versionCreated",
"valueString": "2.7.1"
},
{
"url": "http://terminology.hl7.org/v2plusvocab/StructureDefinition/codesystem-versionHistory",
"valueString": "generate correct history somehow"
},
{
"url": "http://terminology.hl7.org/v2plusvocab/StructureDefinition/codesystem-tableNo",
"valueString": "0369"
}
],
"url": "http://terminology.hl7.org/v2plusvocab/CodeSystem/specimenRole",
"identifier": [
{
"system": "urn:ietf:rfc:3986",
"value": "urn:oid:2.16.840.1.113883.18.227"
}
],
"version": "1.1.0",
"name": "SpecimenRole",
"title": "Specimen Role (2.7.1 - 1.1.0)",
"status": "active",
"experimental": true,
"date": "2026-01-27T19:48:36+00:00",
"publisher": "HL7/FO",
"contact": [
{
"name": "HL7/FO",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org"
}
]
}
],
"description": "HL7-defined code system of concepts that identify the role of a sample. Used in HL7 Version 2.x messaging in the Specimen (SPM) and Observation Request (OBR) segments.",
"copyright": "HL7 Inc., 2026",
"caseSensitive": true,
"compositional": false,
"content": "complete",
"property": [
{
"code": "versionIntroduced",
"uri": "http://terminology.hl7.org/v2plusvocab/CodeSystem/Property#versionIntroduced",
"description": "version when was this code introduced",
"type": "string"
},
{
"code": "versionDeprecated",
"uri": "http://terminology.hl7.org/v2plusvocab/CodeSystem/Property#versionDeprecated",
"description": "version when was this code deprecated",
"type": "string"
},
{
"code": "status",
"uri": "http://hl7.org/fhir/concept-properties#status",
"description": "A code that indicates the status of the concept. Typical values are active, experimental, deprecated, and retired",
"type": "code"
},
{
"code": "comment",
"uri": "http://terminology.hl7.org/v2plusvocab/CodeSystem/Property#comment",
"description": "A string that provides additional detail pertinent to the use or understanding of the concept",
"type": "string"
},
{
"code": "usage",
"uri": "http://terminology.hl7.org/v2plusvocab/CodeSystem/Property#usage",
"description": "usage notes for this code",
"type": "string"
},
{
"code": "modified",
"uri": "http://terminology.hl7.org/v2plusvocab/CodeSystem/Property#modified",
"description": "date of last modification",
"type": "dateTime"
}
],
"concept": [
{
"code": "B",
"display": "Blind Sample",
"definition": "Blind Sample",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.4"
}
]
},
{
"code": "C",
"display": "Calibrator, used for initial setting of calibration",
"definition": "Calibrator, used for initial setting of calibration",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.4"
}
]
},
{
"code": "E",
"display": "Electronic QC, used with manufactured reference providing signals that simulate QC results",
"definition": "Electronic QC, used with manufactured reference providing signals that simulate QC results",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.5"
}
]
},
{
"code": "F",
"display": "Specimen used for testing proficiency of the organization performing the testing (Filler)",
"definition": "Specimen used for testing proficiency of the organization performing the testing (Filler)",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.5"
}
]
},
{
"code": "G",
"display": "Group (where a specimen consists of multiple individual elements that are not individually identified)",
"definition": "Group (where a specimen consists of multiple individual elements that are not individually identified)",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.5"
}
]
},
{
"code": "L",
"display": "Pool (aliquots of individual specimens combined to form a single specimen representing all of the components.)",
"definition": "Pool (aliquots of individual specimens combined to form a single specimen representing all of the components.)",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.5"
}
]
},
{
"code": "O",
"display": "Specimen used for testing Operator Proficiency",
"definition": "Specimen used for testing Operator Proficiency",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.5"
}
]
},
{
"code": "P",
"display": "Patient",
"definition": "Patient",
"property": [
{
"code": "comment",
"valueString": "default if blank component value"
},
{
"code": "versionIntroduced",
"valueString": "2.4"
}
]
},
{
"code": "Q",
"display": "Control specimen",
"definition": "Control specimen",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.4"
}
]
},
{
"code": "R",
"display": "Replicate",
"definition": "Replicate (of patient sample as a control)",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.4"
}
]
},
{
"code": "V",
"display": "Verifying Calibrator",
"definition": "Verifying Calibrator, used for periodic calibration checks",
"property": [
{
"code": "versionIntroduced",
"valueString": "2.5"
}
]
}
]
}