Package | hl7.terminology |
Resource Type | CodeSystem |
Id | v2-0472 |
FHIR Version | R5 |
Source | http://terminology.hl7.org/https://build.fhir.org/ig/HL7/UTG/CodeSystem-v2-0472.html |
URL | http://terminology.hl7.org/CodeSystem/v2-0472 |
Version | 2.0.0 |
Status | active |
Date | 2019-12-01 |
Name | TqConjunctionId |
Title | tqConjunctionId |
Realm | uv |
Authority | hl7 |
Description | HL7-defined code system of concepts specifying that a second timing specification is to follow using the repeat delimiter. Used in HL7 Version 2.x messaging in the TQ1 segment. |
Purpose | Underlying Master Code System for V2 table 0472 (TQ Conjunction ID) |
Copyright | This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html |
Content | complete |
ValueSet | |
v2-0472 | hl7VS-tqConjunctionId |
2.16.840.1.114222.4.11.3353 | TQ Conjunction ID (HL7) |
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: CodeSystem v2-0472
Properties
This code system defines the following properties for its concepts
Name | Code | URI | Type | Description |
status | status | http://terminology.hl7.org/CodeSystem/utg-concept-properties#status | code | Status of the concept |
deprecated | deprecated | http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated | code | Version of HL7 in which the code was deprecated |
V2 Concept Comment | v2-concComment | http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment | string | V2 Concept Comment |
V2 Concept Comment As Published | v2-concCommentAsPub | http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub | string | V2 Concept Comment As Published |
Concepts
This case-sensitive code system http://terminology.hl7.org/CodeSystem/v2-0472
defines the following codes in a Is-A hierarchy:
{ "resourceType": "CodeSystem", "id": "v2-0472", "text": { "status": "generated", "div": "<!-- snip (see above) -->" }, "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode": "oo" } ], "url": "http://terminology.hl7.org/CodeSystem/v2-0472", "identifier": [ { "system": "urn:ietf:rfc:3986", "value": "urn:oid:2.16.840.1.113883.18.300" } ], "version": "2.0.0", "name": "TqConjunctionId", "title": "tqConjunctionId", "status": "active", "experimental": false, "date": "2019-12-01", "publisher": "Health Level Seven International", "contact": [ { "telecom": [ { "system": "url", "value": "http://hl7.org" }, { "system": "email", "value": "hq@HL7.org" } ] } ], "description": "HL7-defined code system of concepts specifying that a second timing specification is to follow using the repeat delimiter. Used in HL7 Version 2.x messaging in the TQ1 segment.", "purpose": "Underlying Master Code System for V2 table 0472 (TQ Conjunction ID)", "copyright": "This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html", "caseSensitive": true, "valueSet": "http://terminology.hl7.org/ValueSet/v2-0472", "hierarchyMeaning": "is-a", "compositional": false, "versionNeeded": false, "content": "complete", "property": [ { "code": "status", "uri": "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status", "description": "Status of the concept", "type": "code" }, { "code": "deprecated", "uri": "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated", "description": "Version of HL7 in which the code was deprecated", "type": "code" }, { "code": "v2-concComment", "uri": "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment", "description": "V2 Concept Comment", "type": "string" }, { "code": "v2-concCommentAsPub", "uri": "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentAsPub", "description": "V2 Concept Comment As Published", "type": "string" } ], "concept": [ { "id": "4869", "code": "S", "display": "Synchronous", "definition": "Synchronous", "property": [ { "code": "v2-concComment", "valueString": "Do the next specification after this one (unless otherwise constrained by the following fields: TQ1-7-start date/time and TQ1-8-end date/time). An \"S\" specification implies that the second timing sequence follows the first, e.g., when a service request is written to measure blood pressure Q15 minutes for the 1st hour, then every 2 hours for the next day." }, { "code": "v2-concCommentAsPub", "valueString": "Do the next specification after this one (unless otherwise constrained by the following fields: TQ1-7-start date/time and TQ1-8-end date/time). An \"S\" specification implies that the second timing sequence follows the first, e.g., when a service request is written to measure blood pressure Q15 minutes for the 1st hour, then every 2 hours for the next day." }, { "code": "status", "valueCode": "A" } ] }, { "id": "4870", "code": "A", "display": "Asynchronous", "definition": "Asynchronous", "property": [ { "code": "v2-concComment", "valueString": "Do the next specification in parallel with this one (unless otherwise constrained by the following fields: TQ1-7-start date/time and TQ1-8-end date/time). The conjunction of \"A\" specifies two parallel instructions, as are sometimes used in medication, e.g., prednisone given at 1 tab on Monday, Wednesday, Friday, and at 1/2 tab on Tuesday, Thursday, Saturday, Sunday." }, { "code": "v2-concCommentAsPub", "valueString": "Do the next specification in parallel with this one (unless otherwise constrained by the following fields: TQ1-7-start date/time and TQ1-8-end date/time). The conjunction of \"A\" specifies two parallel instructions, as are sometimes used in medication, e.g., prednisone given at 1 tab on Monday, Wednesday, Friday, and at 1/2 tab on Tuesday, Thursday, Saturday, Sunday." }, { "code": "status", "valueCode": "A" } ] }, { "id": "4871", "code": "C", "display": "Actuation Time", "definition": "Actuation Time", "property": [ { "code": "v2-concComment", "valueString": "It will be followed by a completion time for the service. This code allows one to distinguish between the time and priority at which a service should be actuated (e.g., blood should be drawn) and the time and priority at which a service should be completed (e.g., results should be reported)." }, { "code": "v2-concCommentAsPub", "valueString": "It will be followed by a completion time for the service. This code allows one to distinguish between the time and priority at which a service should be actuated (e.g., blood should be drawn) and the time and priority at which a service should be completed (e.g., results should be reported)." }, { "code": "status", "valueCode": "A" } ] } ] }