FHIR © HL7.org  |  Server Home  |  XIG Home  |  XIG Stats  |  Server Source  |  FHIR  

FHIR IG Statistics: CodeSystem/v2-0369

Packagehl7.terminology
Resource TypeCodeSystem
Idv2-0369
FHIR VersionR5
Sourcehttp://terminology.hl7.org/https://build.fhir.org/ig/HL7/UTG/CodeSystem-v2-0369.html
URLhttp://terminology.hl7.org/CodeSystem/v2-0369
Version2.0.0
Statusactive
Date2019-12-01
NameSpecimenRole
TitlespecimenRole
Realmuv
Authorityhl7
DescriptionHL7-defined code system of concepts that identify the role of a sample. Used in HL7 Version 2.x messaging in the Specimen (SPM) and Observation Request (OBR) segments.
PurposeUnderlying Master Code System for V2 table 0369 (Specimen Role)
CopyrightThis material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html
Contentcomplete

Resources that use this resource

ValueSet
v2-0369hl7VS-specimenRole
2.16.840.1.114222.4.11.1046Specimen Role
2.16.840.1.114222.4.11.7107VPD Specimen Role

Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: CodeSystem v2-0369

Properties

This code system defines the following properties for its concepts

NameCodeURITypeDescription
statusstatushttp://terminology.hl7.org/CodeSystem/utg-concept-properties#statuscodeStatus of the concept
deprecateddeprecatedhttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecatedcodeVersion of HL7 in which the code was deprecated
V2 Concept Commentv2-concCommenthttp://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concCommentstringV2 Concept Comment

Concepts

This case-sensitive code system http://terminology.hl7.org/CodeSystem/v2-0369 defines the following codes in a Is-A hierarchy:

CodeDisplayDefinitionstatusV2 Concept Comment
B Blind SampleUsed to test the validity of the measurement process, where the composition of the sample is unknown except to the person submitting it.A
C CalibratorUsed for initial setting of calibration of the instrument.A
E Electronic QCUsed with manufactured reference providing signals that simulate QC resultsA
F Filler Organization ProficiencySpecimen used for testing proficiency of the organization performing the testing (Filler).A
G GroupUsed when solid specimens consist of multiple individual elements that are not individually identified but can be separated again into the original specimens. The identifiers of the original specimens may be tracked.A
H Historical SpecimenThis identifies a parent specimen to the specimen that is submitted for testingNThe order of specimen processing can be derived from the SPM-3 value in all SPM segments in the message. More than one historical SPM can be submitted, each SPM describes one step in the derivation process of the specimen submitted for testing.
L PoolUsed when aliquots of liquid individual specimens are combined to form a single specimen representing all of the components that are not individually identified. The identifiers of the original specimens may be tracked.A
O Operator ProficiencySpecimen used for testing Operator Proficiency.A
P PatientUsed for any patient sample.AIf the component is not valued (blank) this represents the default meaning.
Q Control specimenUsed when specimen is the control specimen (either positive or negative).A
R Replicate (of patient sample as a control)Used when a patient sample is re-run as a control for a repeat test.A
V Verifying CalibratorUsed for periodic calibration checks.A

Source

{
  "resourceType": "CodeSystem",
  "id": "v2-0369",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "oo"
    }
  ],
  "url": "http://terminology.hl7.org/CodeSystem/v2-0369",
  "identifier": [
    {
      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:2.16.840.1.113883.18.227"
    }
  ],
  "version": "2.0.0",
  "name": "SpecimenRole",
  "title": "specimenRole",
  "status": "active",
  "experimental": false,
  "date": "2019-12-01",
  "publisher": "Health Level Seven International",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://hl7.org"
        },
        {
          "system": "email",
          "value": "hq@HL7.org"
        }
      ]
    }
  ],
  "description": "HL7-defined code system of concepts that identify the role of a sample.  Used in HL7 Version 2.x messaging in the Specimen (SPM) and Observation Request (OBR) segments.",
  "purpose": "Underlying Master Code System for V2 table 0369 (Specimen Role)",
  "copyright": "This material derives from the HL7 Terminology (THO). THO is copyright ©1989+ Health Level Seven International and is made available under the CC0 designation. For more licensing information see: https://terminology.hl7.org/license.html",
  "caseSensitive": true,
  "valueSet": "http://terminology.hl7.org/ValueSet/v2-0369",
  "hierarchyMeaning": "is-a",
  "compositional": false,
  "versionNeeded": false,
  "content": "complete",
  "property": [
    {
      "code": "status",
      "uri": "http://terminology.hl7.org/CodeSystem/utg-concept-properties#status",
      "description": "Status of the concept",
      "type": "code"
    },
    {
      "code": "deprecated",
      "uri": "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-table-deprecated",
      "description": "Version of HL7 in which the code was deprecated",
      "type": "code"
    },
    {
      "code": "v2-concComment",
      "uri": "http://terminology.hl7.org/CodeSystem/utg-concept-properties#v2-concComment",
      "description": "V2 Concept Comment",
      "type": "string"
    }
  ],
  "concept": [
    {
      "id": "3714",
      "code": "B",
      "display": "Blind Sample",
      "definition": "Used to test the validity of the measurement process, where the composition of the sample is unknown except to the person submitting it.",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3715",
      "code": "C",
      "display": "Calibrator",
      "definition": "Used for initial setting of calibration of the instrument.",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3716",
      "code": "E",
      "display": "Electronic QC",
      "definition": "Used with manufactured reference providing signals that simulate QC results",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3717",
      "code": "F",
      "display": "Filler Organization Proficiency",
      "definition": "Specimen used for testing proficiency of the organization performing the testing (Filler).",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3718",
      "code": "G",
      "display": "Group",
      "definition": "Used when solid specimens consist of multiple individual elements that are not individually identified but can be separated again into the original specimens.  The identifiers of the original specimens may be tracked.",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3719",
      "code": "H",
      "display": "Historical Specimen",
      "definition": "This identifies a parent specimen to the specimen that is submitted for testing",
      "property": [
        {
          "code": "v2-concComment",
          "valueString": "The order of specimen processing can be derived from the SPM-3 value in all SPM segments in the message.  More than one historical SPM can be submitted, each SPM describes one step in the derivation process of the specimen submitted for testing."
        },
        {
          "code": "status",
          "valueCode": "N"
        }
      ]
    },
    {
      "id": "3720",
      "code": "L",
      "display": "Pool",
      "definition": "Used when aliquots of liquid individual specimens are combined to form a single specimen representing all of the components that are not individually identified.  The identifiers of the original specimens may be tracked.",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3721",
      "code": "O",
      "display": "Operator Proficiency",
      "definition": "Specimen used for testing Operator Proficiency.",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3722",
      "code": "P",
      "display": "Patient",
      "definition": "Used for any patient sample.",
      "property": [
        {
          "code": "v2-concComment",
          "valueString": "If the component is not valued (blank) this represents the default meaning."
        },
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3723",
      "code": "Q",
      "display": "Control specimen",
      "definition": "Used when specimen is the control specimen (either positive or negative).",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3724",
      "code": "R",
      "display": "Replicate (of patient sample as a control)",
      "definition": "Used when a patient sample is re-run as a control for a repeat test.",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    },
    {
      "id": "3725",
      "code": "V",
      "display": "Verifying Calibrator",
      "definition": "Used for periodic calibration checks.",
      "property": [
        {
          "code": "status",
          "valueCode": "A"
        }
      ]
    }
  ]
}