FHIR IG analytics| Package | hl7.fhir.uv.xver-r5.r4 |
| Resource Type | ConceptMap |
| Id | ConceptMap-R5-DeviceDefinition-element-map-to-R4.json |
| FHIR Version | R4 |
| Source | http://hl7.org/fhir/uv/xver-r5.r4/0.1.0/ConceptMap-R5-DeviceDefinition-element-map-to-R4.html |
| URL | http://hl7.org/fhir/uv/xver/ConceptMap/R5-DeviceDefinition-element-map-to-R4 |
| Version | 0.1.0 |
| Status | active |
| Date | 2026-03-17T16:04:44.9668049-05:00 |
| Name | R5DeviceDefinitionElementMapToR4 |
| Title | Cross-version mapping for FHIR R5 DeviceDefinition to FHIR R4 DeviceDefinition |
| Realm | uv |
| Authority | hl7 |
| Description | This ConceptMap represents cross-version mappings for elements from a FHIR R5 DeviceDefinition to FHIR R4. |
No resources found
| StructureDefinition | ||
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.chargeItem | Cross-version Extension for R5.DeviceDefinition.chargeItem for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.classification | Cross-version Extension for R5.DeviceDefinition.classification for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.correctiveAction | Cross-version Extension for R5.DeviceDefinition.correctiveAction for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.guideline | Cross-version Extension for R5.DeviceDefinition.guideline for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.hasPart | Cross-version Extension for R5.DeviceDefinition.hasPart for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.link | Cross-version Extension for R5.DeviceDefinition.link for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.packaging | Cross-version Extension for R5.DeviceDefinition.packaging for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.partNumber | Cross-version Extension for R5.DeviceDefinition.partNumber for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.productionIdentifierInUDI | Cross-version Extension for R5.DeviceDefinition.productionIdentifierInUDI for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.property.value | Cross-version Extension for R5.DeviceDefinition.property.value[x] for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.regulatoryIdentifier | Cross-version Extension for R5.DeviceDefinition.regulatoryIdentifier for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4#0.1.0 | extension-DeviceDefinition.udiDeviceIdentifier | R5: udiDeviceIdentifier |
| hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2 | extension-DeviceDefinition.udiDeviceIdentifier.marketDistribution | Cross-version Extension for R5.DeviceDefinition.udiDeviceIdentifier.marketDistribution for use in FHIR R4 |
| hl7.fhir.uv.xver-r5.r4#0.1.0 | extension-DeviceDefinition.version.component | R5: The hardware or software module of the device to which the version applies (new) |
| hl7.fhir.uv.xver-r5.r4#0.1.0 | extension-DeviceDefinition.version.type | R5: The type of the device version, e.g. manufacturer, approved, internal (new) |
| hl7.fhir.uv.xver-r5.r4#0.1.0 | extension-DeviceDefinition.version.value | R5: The version text (new) |
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap R5-DeviceDefinition-element-map-to-R4
Mapping from http://hl7.org/fhir/5.0 to http://hl7.org/fhir/4.0
Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to DeviceDefinitionversion: 4.0.1)
| Source Concept Details | Relationship | Target Concept Details | Comment | ||
| Codes from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 | Codes from DeviceDefinition | ||||
| DeviceDefinition.meta | meta | is equivalent to | DeviceDefinition.meta | DeviceDefinition.meta | Element `DeviceDefinition.meta` is mapped to FHIR R4 element `DeviceDefinition.meta` as `Equivalent`. |
| DeviceDefinition.implicitRules | implicitRules | is equivalent to | DeviceDefinition.implicitRules | DeviceDefinition.implicitRules | Element `DeviceDefinition.implicitRules` is mapped to FHIR R4 element `DeviceDefinition.implicitRules` as `Equivalent`. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc. |
| DeviceDefinition.language | language | is equivalent to | DeviceDefinition.language | DeviceDefinition.language | Element `DeviceDefinition.language` is mapped to FHIR R4 element `DeviceDefinition.language` as `Equivalent`. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). |
| DeviceDefinition.text | text | is equivalent to | DeviceDefinition.text | DeviceDefinition.text | Element `DeviceDefinition.text` is mapped to FHIR R4 element `DeviceDefinition.text` as `Equivalent`. Contained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. |
| DeviceDefinition.contained | contained | is equivalent to | DeviceDefinition.contained | DeviceDefinition.contained | Element `DeviceDefinition.contained` is mapped to FHIR R4 element `DeviceDefinition.contained` as `Equivalent`. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels. |
| DeviceDefinition.identifier | identifier | is equivalent to | DeviceDefinition.identifier | DeviceDefinition.identifier | Element `DeviceDefinition.identifier` is mapped to FHIR R4 element `DeviceDefinition.identifier` as `Equivalent`. |
| DeviceDefinition.udiDeviceIdentifier | udiDeviceIdentifier | maps to wider concept | DeviceDefinition.udiDeviceIdentifier | DeviceDefinition.udiDeviceIdentifier | Element `DeviceDefinition.udiDeviceIdentifier` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier` as `Equivalent`. |
| DeviceDefinition.udiDeviceIdentifier.deviceIdentifier | deviceIdentifier | is equivalent to | DeviceDefinition.udiDeviceIdentifier.deviceIdentifier | DeviceDefinition.udiDeviceIdentifier.deviceIdentifier | Element `DeviceDefinition.udiDeviceIdentifier.deviceIdentifier` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.deviceIdentifier` as `Equivalent`. |
| DeviceDefinition.udiDeviceIdentifier.issuer | issuer | is equivalent to | DeviceDefinition.udiDeviceIdentifier.issuer | DeviceDefinition.udiDeviceIdentifier.issuer | Element `DeviceDefinition.udiDeviceIdentifier.issuer` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.issuer` as `Equivalent`. |
| DeviceDefinition.udiDeviceIdentifier.jurisdiction | jurisdiction | is equivalent to | DeviceDefinition.udiDeviceIdentifier.jurisdiction | DeviceDefinition.udiDeviceIdentifier.jurisdiction | Element `DeviceDefinition.udiDeviceIdentifier.jurisdiction` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.jurisdiction` as `Equivalent`. |
| DeviceDefinition.manufacturer | manufacturer | is equivalent to | DeviceDefinition.manufacturer[x] | DeviceDefinition.manufacturer[x] | Element `DeviceDefinition.manufacturer` is mapped to FHIR R4 element `DeviceDefinition.manufacturer[x]` as `Equivalent`. The target context `DeviceDefinition.manufacturer[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `DeviceDefinition`. |
| DeviceDefinition.deviceName | deviceName | maps to wider concept | DeviceDefinition.deviceName | DeviceDefinition.deviceName | Element `DeviceDefinition.deviceName` is mapped to FHIR R4 element `DeviceDefinition.deviceName` as `Equivalent`. |
| DeviceDefinition.deviceName.name | name | is equivalent to | DeviceDefinition.deviceName.name | DeviceDefinition.deviceName.name | Element `DeviceDefinition.deviceName.name` is mapped to FHIR R4 element `DeviceDefinition.deviceName.name` as `Equivalent`. |
| DeviceDefinition.deviceName.type | type | is equivalent to | DeviceDefinition.deviceName.type | DeviceDefinition.deviceName.type | Element `DeviceDefinition.deviceName.type` is mapped to FHIR R4 element `DeviceDefinition.deviceName.type` as `SourceIsNarrowerThanTarget`. The mappings for `DeviceDefinition.deviceName.type` do not allow expression of the necessary codes, per the bindings on the source and target. |
| DeviceDefinition.modelNumber | modelNumber | is equivalent to | DeviceDefinition.modelNumber | DeviceDefinition.modelNumber | Element `DeviceDefinition.modelNumber` is mapped to FHIR R4 element `DeviceDefinition.modelNumber` as `Equivalent`. |
| DeviceDefinition.conformsTo | conformsTo | maps to wider concept | DeviceDefinition.specialization | DeviceDefinition.specialization | Element `DeviceDefinition.conformsTo` is mapped to FHIR R4 element `DeviceDefinition.specialization` as `Equivalent`. An externally-defined extension that has been mapped as the representation of FHIR R5 element `DeviceDefinition.conformsTo`: `http://hl7.org/fhir/StructureDefinition/device-conformsTo`. |
| DeviceDefinition.conformsTo.category | category | narrower | DeviceDefinition.specialization | DeviceDefinition.specialization | Element `DeviceDefinition.conformsTo.category` is mapped to FHIR R4 element `DeviceDefinition.specialization` as `SourceIsNarrowerThanTarget`. |
| DeviceDefinition.conformsTo.specification | specification | narrower | DeviceDefinition.specialization | DeviceDefinition.specialization | Element `DeviceDefinition.conformsTo.specification` is mapped to FHIR R4 element `DeviceDefinition.specialization` as `SourceIsNarrowerThanTarget`. |
| DeviceDefinition.conformsTo.version | version | is equivalent to | DeviceDefinition.specialization.version | DeviceDefinition.specialization.version | Element `DeviceDefinition.conformsTo.version` is mapped to FHIR R4 element `DeviceDefinition.specialization.version` as `SourceIsBroaderThanTarget`. |
| DeviceDefinition.conformsTo.source | source | is equivalent to | DeviceDefinition.specialization | DeviceDefinition.specialization | Element `DeviceDefinition.conformsTo.source` is mapped to FHIR R4 element `DeviceDefinition.specialization` as `Equivalent`. |
| DeviceDefinition.version | version | maps to wider concept | DeviceDefinition.version | DeviceDefinition.version | Element `DeviceDefinition.version` is mapped to FHIR R4 element `DeviceDefinition.version` as `Equivalent`. |
| DeviceDefinition.safety | safety | is equivalent to | DeviceDefinition.safety | DeviceDefinition.safety | Element `DeviceDefinition.safety` is mapped to FHIR R4 element `DeviceDefinition.safety` as `Equivalent`. |
| DeviceDefinition.shelfLifeStorage | shelfLifeStorage | is equivalent to | DeviceDefinition.shelfLifeStorage | DeviceDefinition.shelfLifeStorage | Element `DeviceDefinition.shelfLifeStorage` is mapped to FHIR R4 element `DeviceDefinition.shelfLifeStorage` as `Equivalent`. |
| DeviceDefinition.languageCode | languageCode | is equivalent to | DeviceDefinition.languageCode | DeviceDefinition.languageCode | Element `DeviceDefinition.languageCode` is mapped to FHIR R4 element `DeviceDefinition.languageCode` as `Equivalent`. |
| DeviceDefinition.property | property | maps to wider concept | DeviceDefinition.property | DeviceDefinition.property | Element `DeviceDefinition.property` is mapped to FHIR R4 element `DeviceDefinition.property` as `Equivalent`. Dynamic or current properties, such as settings, of an individual device are described using a Device instance-specific DeviceMetric and recorded using Observation. Static characteristics of an individual device could also be documented in a [Device] instance. The Device instance's properties, and their values, could be, but need not be, the same as in the associated DeviceDefinition. |
| DeviceDefinition.property.type | type | is equivalent to | DeviceDefinition.property.type | DeviceDefinition.property.type | Element `DeviceDefinition.property.type` is mapped to FHIR R4 element `DeviceDefinition.property.type` as `Equivalent`. |
| DeviceDefinition.property.value[x] | value[x] | is related to | DeviceDefinition.property.valueCode | DeviceDefinition.property.valueCode | Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueQuantity` as `RelatedTo`. Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueCode` as `RelatedTo`. The mappings for `DeviceDefinition.property.value[x]` do not cover the following types: Attachment, boolean, integer, Range, string. This use of string or CodeableConcept is supported to address different purposes The text element of the valueCodeableConcept choice type is used for properties which would usually be coded (such as the size of an implant, or a security classification) but for which there is not currently an appropriate concept in the vocabulary (e.g., a custom implant size, or a security classification which depends on configuration. Otherwise the valueString choice type is used for textual descriptive device properties that cannot be expressed in other elements. |
| is related to | DeviceDefinition.property.valueQuantity | DeviceDefinition.property.valueQuantity | Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueQuantity` as `RelatedTo`. Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueCode` as `RelatedTo`. The mappings for `DeviceDefinition.property.value[x]` do not cover the following types: Attachment, boolean, integer, Range, string. This use of string or CodeableConcept is supported to address different purposes The text element of the valueCodeableConcept choice type is used for properties which would usually be coded (such as the size of an implant, or a security classification) but for which there is not currently an appropriate concept in the vocabulary (e.g., a custom implant size, or a security classification which depends on configuration. Otherwise the valueString choice type is used for textual descriptive device properties that cannot be expressed in other elements. | ||
| DeviceDefinition.owner | owner | is equivalent to | DeviceDefinition.owner | DeviceDefinition.owner | Element `DeviceDefinition.owner` is mapped to FHIR R4 element `DeviceDefinition.owner` as `Equivalent`. |
| DeviceDefinition.contact | contact | is equivalent to | DeviceDefinition.contact | DeviceDefinition.contact | Element `DeviceDefinition.contact` is mapped to FHIR R4 element `DeviceDefinition.contact` as `Equivalent`. An externally-defined extension that has been mapped as the representation of FHIR R5 element `DeviceDefinition.contact`: `http://hl7.org/fhir/StructureDefinition/artifact-contact`. used for troubleshooting etc. |
| DeviceDefinition.note | note | is equivalent to | DeviceDefinition.note | DeviceDefinition.note | Element `DeviceDefinition.note` is mapped to FHIR R4 element `DeviceDefinition.note` as `Equivalent`. |
| DeviceDefinition.material | material | maps to wider concept | DeviceDefinition.material | DeviceDefinition.material | Element `DeviceDefinition.material` is mapped to FHIR R4 element `DeviceDefinition.material` as `Equivalent`. |
| DeviceDefinition.material.substance | substance | is equivalent to | DeviceDefinition.material.substance | DeviceDefinition.material.substance | Element `DeviceDefinition.material.substance` is mapped to FHIR R4 element `DeviceDefinition.material.substance` as `Equivalent`. |
| DeviceDefinition.material.alternate | alternate | is equivalent to | DeviceDefinition.material.alternate | DeviceDefinition.material.alternate | Element `DeviceDefinition.material.alternate` is mapped to FHIR R4 element `DeviceDefinition.material.alternate` as `Equivalent`. |
| DeviceDefinition.material.allergenicIndicator | allergenicIndicator | is equivalent to | DeviceDefinition.material.allergenicIndicator | DeviceDefinition.material.allergenicIndicator | Element `DeviceDefinition.material.allergenicIndicator` is mapped to FHIR R4 element `DeviceDefinition.material.allergenicIndicator` as `Equivalent`. |
Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: udiDeviceIdentifierversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.udiDeviceIdentifier (udiDeviceIdentifier) | is equivalent to | Extension (R5: udiDeviceIdentifier) | Element `DeviceDefinition.udiDeviceIdentifier` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier` as `Equivalent`. |
| DeviceDefinition.udiDeviceIdentifier.deviceIdentifier (deviceIdentifier) | is equivalent to | Extension.extension:deviceIdentifier (R5: The identifier that is to be associated with every Device that references this DeviceDefintiion for the issuer and jurisdiction provided in the DeviceDefinition.udiDeviceIdentifier) | Element `DeviceDefinition.udiDeviceIdentifier.deviceIdentifier` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.deviceIdentifier` as `Equivalent`. |
| DeviceDefinition.udiDeviceIdentifier.issuer (issuer) | is equivalent to | Extension.extension:issuer (R5: issuer) | Element `DeviceDefinition.udiDeviceIdentifier.issuer` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.issuer` as `Equivalent`. |
| DeviceDefinition.udiDeviceIdentifier.jurisdiction (jurisdiction) | is equivalent to | Extension.extension:jurisdiction (R5: jurisdiction) | Element `DeviceDefinition.udiDeviceIdentifier.jurisdiction` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.jurisdiction` as `Equivalent`. |
| DeviceDefinition.udiDeviceIdentifier.marketDistribution (marketDistribution) | maps to wider concept | Extension.extension:marketDistribution (R5: Indicates whether and when the device is available on the market (new)) | Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod (marketPeriod) | maps to wider concept | Extension.extension:marketDistribution.extension:marketPeriod (R5: Begin and end dates for the commercial distribution of the device (new)) | Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` is part of an existing definition because parent element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` requires a cross-version extension. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction (subJurisdiction) | maps to wider concept | Extension.extension:marketDistribution.extension:subJurisdiction (R5: National state or territory where the device is commercialized (new)) | Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` is part of an existing definition because parent element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` requires a cross-version extension. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.udiDeviceIdentifier (udiDeviceIdentifier) | maps to wider concept | Extension.extension:udiDeviceIdentifier | Element `DeviceDefinition.packaging.udiDeviceIdentifier` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension. Element `DeviceDefinition.packaging.udiDeviceIdentifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.udiDeviceIdentifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: Indicates whether and when the device is available on the market (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.udiDeviceIdentifier.marketDistribution (marketDistribution) | maps to wider concept | Extension (R5: Indicates whether and when the device is available on the market (new)) | Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod (marketPeriod) | maps to wider concept | Extension.extension:marketPeriod (R5: Begin and end dates for the commercial distribution of the device (new)) | Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` is part of an existing definition because parent element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` requires a cross-version extension. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction (subJurisdiction) | maps to wider concept | Extension.extension:subJurisdiction (R5: National state or territory where the device is commercialized (new)) | Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` is part of an existing definition because parent element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` requires a cross-version extension. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: Regulatory identifier(s) associated with this device (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.regulatoryIdentifier (regulatoryIdentifier) | maps to wider concept | Extension (R5: Regulatory identifier(s) associated with this device (new)) | Element `DeviceDefinition.regulatoryIdentifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.regulatoryIdentifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). This should not be used for regulatory authorization numbers which are to be captured elsewhere. |
| DeviceDefinition.regulatoryIdentifier.type (type) | maps to wider concept | Extension.extension:type (R5: basic | master | license (new)) | Element `DeviceDefinition.regulatoryIdentifier.type` is part of an existing definition because parent element `DeviceDefinition.regulatoryIdentifier` requires a cross-version extension. Element `DeviceDefinition.regulatoryIdentifier.type` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.regulatoryIdentifier.type` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.regulatoryIdentifier.deviceIdentifier (deviceIdentifier) | maps to wider concept | Extension.extension:deviceIdentifier (R5: The identifier itself (new)) | Element `DeviceDefinition.regulatoryIdentifier.deviceIdentifier` is part of an existing definition because parent element `DeviceDefinition.regulatoryIdentifier` requires a cross-version extension. Element `DeviceDefinition.regulatoryIdentifier.deviceIdentifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.regulatoryIdentifier.deviceIdentifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.regulatoryIdentifier.issuer (issuer) | maps to wider concept | Extension.extension:issuer (R5: The organization that issued this identifier (new)) | Element `DeviceDefinition.regulatoryIdentifier.issuer` is part of an existing definition because parent element `DeviceDefinition.regulatoryIdentifier` requires a cross-version extension. Element `DeviceDefinition.regulatoryIdentifier.issuer` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.regulatoryIdentifier.issuer` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.regulatoryIdentifier.jurisdiction (jurisdiction) | maps to wider concept | Extension.extension:jurisdiction (R5: The jurisdiction to which the deviceIdentifier applies (new)) | Element `DeviceDefinition.regulatoryIdentifier.jurisdiction` is part of an existing definition because parent element `DeviceDefinition.regulatoryIdentifier` requires a cross-version extension. Element `DeviceDefinition.regulatoryIdentifier.jurisdiction` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.regulatoryIdentifier.jurisdiction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: The part number or catalog number of the device (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.partNumber (partNumber) | maps to wider concept | Extension (R5: The part number or catalog number of the device (new)) | Element `DeviceDefinition.partNumber` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.partNumber` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). Alphanumeric Maximum 20. |
Group 6 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: What kind of device or device system this is (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.classification (classification) | maps to wider concept | Extension (R5: What kind of device or device system this is (new)) | Element `DeviceDefinition.classification` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.classification` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). In this element various classifications can be used, such as GMDN, EMDN, SNOMED CT, risk classes, national product codes. |
| DeviceDefinition.classification.type (type) | maps to wider concept | Extension.extension:type (R5: A classification or risk class of the device model (new)) | Element `DeviceDefinition.classification.type` is part of an existing definition because parent element `DeviceDefinition.classification` requires a cross-version extension. Element `DeviceDefinition.classification.type` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.classification.type` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.classification.justification (justification) | maps to wider concept | Extension.extension:justification (R5: Further information qualifying this classification of the device model (new)) | Element `DeviceDefinition.classification.justification` is part of an existing definition because parent element `DeviceDefinition.classification` requires a cross-version extension. Element `DeviceDefinition.classification.justification` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.classification.justification` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 7 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: A device, part of the current one (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.hasPart (hasPart) | maps to wider concept | Extension (R5: A device, part of the current one (new)) | Element `DeviceDefinition.hasPart` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.hasPart` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.hasPart.reference (reference) | maps to wider concept | Extension.extension:reference (R5: Reference to the part (new)) | Element `DeviceDefinition.hasPart.reference` is part of an existing definition because parent element `DeviceDefinition.hasPart` requires a cross-version extension. Element `DeviceDefinition.hasPart.reference` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.hasPart.reference` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.hasPart.count (count) | maps to wider concept | Extension.extension:count (R5: Number of occurrences of the part (new)) | Element `DeviceDefinition.hasPart.count` is part of an existing definition because parent element `DeviceDefinition.hasPart` requires a cross-version extension. Element `DeviceDefinition.hasPart.count` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.hasPart.count` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 8 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: Information about the packaging of the device, i.e. how the device is packaged (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.packaging (packaging) | maps to wider concept | Extension (R5: Information about the packaging of the device, i.e. how the device is packaged (new)) | Element `DeviceDefinition.packaging` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.identifier (identifier) | maps to wider concept | Extension.extension:identifier (R5: Business identifier of the packaged medication (new)) | Element `DeviceDefinition.packaging.identifier` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension. Element `DeviceDefinition.packaging.identifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.identifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.type (type) | maps to wider concept | Extension.extension:type (R5: A code that defines the specific type of packaging (new)) | Element `DeviceDefinition.packaging.type` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension. Element `DeviceDefinition.packaging.type` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.type` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.count (count) | maps to wider concept | Extension.extension:count (R5: The number of items contained in the package (devices or sub-packages) (new)) | Element `DeviceDefinition.packaging.count` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension. Element `DeviceDefinition.packaging.count` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.count` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.distributor (distributor) | maps to wider concept | Extension.extension:distributor (R5: An organization that distributes the packaged device (new)) | Element `DeviceDefinition.packaging.distributor` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension. Element `DeviceDefinition.packaging.distributor` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.distributor` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.distributor.name (name) | maps to wider concept | Extension.extension:distributor.extension:name (R5: Distributor's human-readable name (new)) | Element `DeviceDefinition.packaging.distributor.name` is part of an existing definition because parent element `DeviceDefinition.packaging.distributor` requires a cross-version extension. Element `DeviceDefinition.packaging.distributor.name` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.distributor.name` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.distributor.organizationReference (organizationReference) | maps to wider concept | Extension.extension:distributor.extension:organizationReference (R5: Distributor as an Organization resource (new)) | Element `DeviceDefinition.packaging.distributor.organizationReference` is part of an existing definition because parent element `DeviceDefinition.packaging.distributor` requires a cross-version extension. Element `DeviceDefinition.packaging.distributor.organizationReference` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.distributor.organizationReference` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.udiDeviceIdentifier (udiDeviceIdentifier) | maps to wider concept | Extension.extension:udiDeviceIdentifier (R5: Unique Device Identifier (UDI) Barcode string on the packaging (new)) | Element `DeviceDefinition.packaging.udiDeviceIdentifier` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension. Element `DeviceDefinition.packaging.udiDeviceIdentifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.udiDeviceIdentifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.packaging.packaging (packaging) | maps to wider concept | Extension.extension:packaging (R5: Allows packages within packages (new)) | Element `DeviceDefinition.packaging.packaging` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension. Element `DeviceDefinition.packaging.packaging` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.packaging.packaging` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 9 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: The type of the device version, e.g. manufacturer, approved, internal (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.version.type (type) | maps to wider concept | Extension (R5: The type of the device version, e.g. manufacturer, approved, internal (new)) | Element `DeviceDefinition.version.type` has a context of DeviceDefinition.version based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.version.type` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 10 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: The hardware or software module of the device to which the version applies (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.version.component (component) | maps to wider concept | Extension (R5: The hardware or software module of the device to which the version applies (new)) | Element `DeviceDefinition.version.component` has a context of DeviceDefinition.version based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.version.component` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). Note that the module of the device would not need to be tracked as a separate device, e.g., using different UDI, thus would typically involve one or more software modules. For example, a device may involve two software modules each on a different version. |
Group 11 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: The version text (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.version.value (value) | maps to wider concept | Extension (R5: The version text (new)) | Element `DeviceDefinition.version.value` has a context of DeviceDefinition.version based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.version.value` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 12 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: Value of the property additional typesversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.property.value[x] (value[x]) | maps to wider concept | Extension (R5: Value of the property additional types) | Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueQuantity` as `RelatedTo`. Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueCode` as `RelatedTo`. The mappings for `DeviceDefinition.property.value[x]` do not cover the following types: Attachment, boolean, integer, Range, string. This use of string or CodeableConcept is supported to address different purposes The text element of the valueCodeableConcept choice type is used for properties which would usually be coded (such as the size of an implant, or a security classification) but for which there is not currently an appropriate concept in the vocabulary (e.g., a custom implant size, or a security classification which depends on configuration. Otherwise the valueString choice type is used for textual descriptive device properties that cannot be expressed in other elements. |
Group 13 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: An associated device, attached to, used with, communicating with or linking a previous or new device model to the focal device (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.link (link) | maps to wider concept | Extension (R5: An associated device, attached to, used with, communicating with or linking a previous or new device model to the focal device (new)) | Element `DeviceDefinition.link` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.link` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.link.relation (relation) | maps to wider concept | Extension.extension:relation (R5: The type indicates the relationship of the related device to the device instance (new)) | Element `DeviceDefinition.link.relation` is part of an existing definition because parent element `DeviceDefinition.link` requires a cross-version extension. Element `DeviceDefinition.link.relation` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.link.relation` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.link.relatedDevice (relatedDevice) | maps to wider concept | Extension.extension:relatedDevice (R5: A reference to the linked device (new)) | Element `DeviceDefinition.link.relatedDevice` is part of an existing definition because parent element `DeviceDefinition.link` requires a cross-version extension. Element `DeviceDefinition.link.relatedDevice` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.link.relatedDevice` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 14 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: lot-number | manufactured-date | serial-number | expiration-date | biological-source | software-version (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.productionIdentifierInUDI (productionIdentifierInUDI) | maps to wider concept | Extension (R5: lot-number | manufactured-date | serial-number | expiration-date | biological-source | software-version (new)) | Element `DeviceDefinition.productionIdentifierInUDI` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.productionIdentifierInUDI` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 15 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: Information aimed at providing directions for the usage of this model of device (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.guideline (guideline) | maps to wider concept | Extension (R5: Information aimed at providing directions for the usage of this model of device (new)) | Element `DeviceDefinition.guideline` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.guideline` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). For more structured data, a ClinicalUseDefinition that points to the DeviceDefinition can be used. |
| DeviceDefinition.guideline.useContext (useContext) | maps to wider concept | Extension.extension:useContext (R5: The circumstances that form the setting for using the device (new)) | Element `DeviceDefinition.guideline.useContext` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension. Element `DeviceDefinition.guideline.useContext` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.guideline.useContext` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.guideline.usageInstruction (usageInstruction) | maps to wider concept | Extension.extension:usageInstruction (R5: Detailed written and visual directions for the user on how to use the device (new)) | Element `DeviceDefinition.guideline.usageInstruction` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension. Element `DeviceDefinition.guideline.usageInstruction` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.guideline.usageInstruction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.guideline.relatedArtifact (relatedArtifact) | is equivalent to | Extension.extension:relatedArtifact (R5: A source of information or reference for this guideline (new)) | Element `DeviceDefinition.guideline.relatedArtifact` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension. Element `DeviceDefinition.guideline.relatedArtifact` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.guideline.relatedArtifact` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.guideline.indication (indication) | maps to wider concept | Extension.extension:indication (R5: A clinical condition for which the device was designed to be used (new)) | Element `DeviceDefinition.guideline.indication` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension. Element `DeviceDefinition.guideline.indication` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.guideline.indication` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). A ClinicalUseDefinition that points to the DeviceDefinition can be used if more structured data is needed. |
| DeviceDefinition.guideline.contraindication (contraindication) | maps to wider concept | Extension.extension:contraindication (R5: A specific situation when a device should not be used because it may cause harm (new)) | Element `DeviceDefinition.guideline.contraindication` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension. Element `DeviceDefinition.guideline.contraindication` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.guideline.contraindication` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). A ClinicalUseDefinition that points to the DeviceDefinition can be used if more structured data is needed. |
| DeviceDefinition.guideline.warning (warning) | maps to wider concept | Extension.extension:warning (R5: Specific hazard alert information that a user needs to know before using the device (new)) | Element `DeviceDefinition.guideline.warning` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension. Element `DeviceDefinition.guideline.warning` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.guideline.warning` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). A ClinicalUseDefinition that points to the DeviceDefinition can be used if more structured data is needed. |
| DeviceDefinition.guideline.intendedUse (intendedUse) | maps to wider concept | Extension.extension:intendedUse (R5: A description of the general purpose or medical use of the device or its function (new)) | Element `DeviceDefinition.guideline.intendedUse` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension. Element `DeviceDefinition.guideline.intendedUse` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.guideline.intendedUse` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 16 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: Tracking of latest field safety corrective action (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.correctiveAction (correctiveAction) | maps to wider concept | Extension (R5: Tracking of latest field safety corrective action (new)) | Element `DeviceDefinition.correctiveAction` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.correctiveAction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.correctiveAction.recall (recall) | maps to wider concept | Extension.extension:recall (R5: Whether the corrective action was a recall (new)) | Element `DeviceDefinition.correctiveAction.recall` is part of an existing definition because parent element `DeviceDefinition.correctiveAction` requires a cross-version extension. Element `DeviceDefinition.correctiveAction.recall` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.correctiveAction.recall` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). When a field safety action has been initiated but not yet resulted in a recall, this element will be set to 'false'. |
| DeviceDefinition.correctiveAction.scope (scope) | maps to wider concept | Extension.extension:scope (R5: model | lot-numbers | serial-numbers (new)) | Element `DeviceDefinition.correctiveAction.scope` is part of an existing definition because parent element `DeviceDefinition.correctiveAction` requires a cross-version extension. Element `DeviceDefinition.correctiveAction.scope` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.correctiveAction.scope` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.correctiveAction.period (period) | maps to wider concept | Extension.extension:period (R5: Start and end dates of the corrective action (new)) | Element `DeviceDefinition.correctiveAction.period` is part of an existing definition because parent element `DeviceDefinition.correctiveAction` requires a cross-version extension. Element `DeviceDefinition.correctiveAction.period` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.correctiveAction.period` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
Group 17 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceDefinition|5.0.0 to R5: Billing code or reference associated with the device (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| DeviceDefinition.chargeItem (chargeItem) | maps to wider concept | Extension (R5: Billing code or reference associated with the device (new)) | Element `DeviceDefinition.chargeItem` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.chargeItem` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.chargeItem.chargeItemCode (chargeItemCode) | maps to wider concept | Extension.extension:chargeItemCode (R5: The code or reference for the charge item (new)) | Element `DeviceDefinition.chargeItem.chargeItemCode` is part of an existing definition because parent element `DeviceDefinition.chargeItem` requires a cross-version extension. Element `DeviceDefinition.chargeItem.chargeItemCode` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.chargeItem.chargeItemCode` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.chargeItem.count (count) | maps to wider concept | Extension.extension:count (R5: Coefficient applicable to the billing code (new)) | Element `DeviceDefinition.chargeItem.count` is part of an existing definition because parent element `DeviceDefinition.chargeItem` requires a cross-version extension. Element `DeviceDefinition.chargeItem.count` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.chargeItem.count` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.chargeItem.effectivePeriod (effectivePeriod) | maps to wider concept | Extension.extension:effectivePeriod (R5: A specific time period in which this charge item applies (new)) | Element `DeviceDefinition.chargeItem.effectivePeriod` is part of an existing definition because parent element `DeviceDefinition.chargeItem` requires a cross-version extension. Element `DeviceDefinition.chargeItem.effectivePeriod` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.chargeItem.effectivePeriod` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
| DeviceDefinition.chargeItem.useContext (useContext) | maps to wider concept | Extension.extension:useContext (R5: The context to which this charge item applies (new)) | Element `DeviceDefinition.chargeItem.useContext` is part of an existing definition because parent element `DeviceDefinition.chargeItem` requires a cross-version extension. Element `DeviceDefinition.chargeItem.useContext` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`. Element `DeviceDefinition.chargeItem.useContext` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element). |
{
"resourceType": "ConceptMap",
"id": "R5-DeviceDefinition-element-map-to-R4",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "fhir"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 0,
"_valueInteger": {
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r5.r4"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "trial-use",
"_valueCode": {
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r5.r4"
}
]
}
}
],
"url": "http://hl7.org/fhir/uv/xver/ConceptMap/R5-DeviceDefinition-element-map-to-R4",
"version": "0.1.0",
"name": "R5DeviceDefinitionElementMapToR4",
"title": "Cross-version mapping for FHIR R5 DeviceDefinition to FHIR R4 DeviceDefinition",
"status": "active",
"experimental": false,
"date": "2026-03-17T16:04:44.9668049-05:00",
"contact": [
{
"name": "FHIR Infrastructure",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/fiwg"
}
]
}
],
"description": "This ConceptMap represents cross-version mappings for elements from a FHIR R5 DeviceDefinition to FHIR R4.",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001",
"display": "World"
}
]
}
],
"sourceCanonical": "http://hl7.org/fhir/5.0",
"targetUri": "http://hl7.org/fhir/4.0",
"group": [
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"targetVersion": "4.0.1",
"element": [
{
"code": "DeviceDefinition.meta",
"display": "meta",
"target": [
{
"code": "DeviceDefinition.meta",
"display": "DeviceDefinition.meta",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.meta` is mapped to FHIR R4 element `DeviceDefinition.meta` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.implicitRules",
"display": "implicitRules",
"target": [
{
"code": "DeviceDefinition.implicitRules",
"display": "DeviceDefinition.implicitRules",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.implicitRules` is mapped to FHIR R4 element `DeviceDefinition.implicitRules` as `Equivalent`.\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc."
}
]
},
{
"code": "DeviceDefinition.language",
"display": "language",
"target": [
{
"code": "DeviceDefinition.language",
"display": "DeviceDefinition.language",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.language` is mapped to FHIR R4 element `DeviceDefinition.language` as `Equivalent`.\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
}
]
},
{
"code": "DeviceDefinition.text",
"display": "text",
"target": [
{
"code": "DeviceDefinition.text",
"display": "DeviceDefinition.text",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.text` is mapped to FHIR R4 element `DeviceDefinition.text` as `Equivalent`.\nContained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
}
]
},
{
"code": "DeviceDefinition.contained",
"display": "contained",
"target": [
{
"code": "DeviceDefinition.contained",
"display": "DeviceDefinition.contained",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.contained` is mapped to FHIR R4 element `DeviceDefinition.contained` as `Equivalent`.\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels."
}
]
},
{
"code": "DeviceDefinition.identifier",
"display": "identifier",
"target": [
{
"code": "DeviceDefinition.identifier",
"display": "DeviceDefinition.identifier",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.identifier` is mapped to FHIR R4 element `DeviceDefinition.identifier` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier",
"display": "udiDeviceIdentifier",
"target": [
{
"code": "DeviceDefinition.udiDeviceIdentifier",
"display": "DeviceDefinition.udiDeviceIdentifier",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.deviceIdentifier",
"display": "deviceIdentifier",
"target": [
{
"code": "DeviceDefinition.udiDeviceIdentifier.deviceIdentifier",
"display": "DeviceDefinition.udiDeviceIdentifier.deviceIdentifier",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.deviceIdentifier` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.deviceIdentifier` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.issuer",
"display": "issuer",
"target": [
{
"code": "DeviceDefinition.udiDeviceIdentifier.issuer",
"display": "DeviceDefinition.udiDeviceIdentifier.issuer",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.issuer` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.issuer` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.jurisdiction",
"display": "jurisdiction",
"target": [
{
"code": "DeviceDefinition.udiDeviceIdentifier.jurisdiction",
"display": "DeviceDefinition.udiDeviceIdentifier.jurisdiction",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.jurisdiction` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.jurisdiction` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.manufacturer",
"display": "manufacturer",
"target": [
{
"code": "DeviceDefinition.manufacturer[x]",
"display": "DeviceDefinition.manufacturer[x]",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.manufacturer` is mapped to FHIR R4 element `DeviceDefinition.manufacturer[x]` as `Equivalent`.\nThe target context `DeviceDefinition.manufacturer[x]` is a choice-type element and cannot directly hold extensions. The context is moved up to parent element `DeviceDefinition`."
}
]
},
{
"code": "DeviceDefinition.deviceName",
"display": "deviceName",
"target": [
{
"code": "DeviceDefinition.deviceName",
"display": "DeviceDefinition.deviceName",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.deviceName` is mapped to FHIR R4 element `DeviceDefinition.deviceName` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.deviceName.name",
"display": "name",
"target": [
{
"code": "DeviceDefinition.deviceName.name",
"display": "DeviceDefinition.deviceName.name",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.deviceName.name` is mapped to FHIR R4 element `DeviceDefinition.deviceName.name` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.deviceName.type",
"display": "type",
"target": [
{
"code": "DeviceDefinition.deviceName.type",
"display": "DeviceDefinition.deviceName.type",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.deviceName.type` is mapped to FHIR R4 element `DeviceDefinition.deviceName.type` as `SourceIsNarrowerThanTarget`.\nThe mappings for `DeviceDefinition.deviceName.type` do not allow expression of the necessary codes, per the bindings on the source and target."
}
]
},
{
"code": "DeviceDefinition.modelNumber",
"display": "modelNumber",
"target": [
{
"code": "DeviceDefinition.modelNumber",
"display": "DeviceDefinition.modelNumber",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.modelNumber` is mapped to FHIR R4 element `DeviceDefinition.modelNumber` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.conformsTo",
"display": "conformsTo",
"target": [
{
"code": "DeviceDefinition.specialization",
"display": "DeviceDefinition.specialization",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.conformsTo` is mapped to FHIR R4 element `DeviceDefinition.specialization` as `Equivalent`.\nAn externally-defined extension that has been mapped as the representation of FHIR R5 element `DeviceDefinition.conformsTo`: `http://hl7.org/fhir/StructureDefinition/device-conformsTo`."
}
]
},
{
"code": "DeviceDefinition.conformsTo.category",
"display": "category",
"target": [
{
"code": "DeviceDefinition.specialization",
"display": "DeviceDefinition.specialization",
"equivalence": "narrower",
"comment": "Element `DeviceDefinition.conformsTo.category` is mapped to FHIR R4 element `DeviceDefinition.specialization` as `SourceIsNarrowerThanTarget`."
}
]
},
{
"code": "DeviceDefinition.conformsTo.specification",
"display": "specification",
"target": [
{
"code": "DeviceDefinition.specialization",
"display": "DeviceDefinition.specialization",
"equivalence": "narrower",
"comment": "Element `DeviceDefinition.conformsTo.specification` is mapped to FHIR R4 element `DeviceDefinition.specialization` as `SourceIsNarrowerThanTarget`."
}
]
},
{
"code": "DeviceDefinition.conformsTo.version",
"display": "version",
"target": [
{
"code": "DeviceDefinition.specialization.version",
"display": "DeviceDefinition.specialization.version",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.conformsTo.version` is mapped to FHIR R4 element `DeviceDefinition.specialization.version` as `SourceIsBroaderThanTarget`."
}
]
},
{
"code": "DeviceDefinition.conformsTo.source",
"display": "source",
"target": [
{
"code": "DeviceDefinition.specialization",
"display": "DeviceDefinition.specialization",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.conformsTo.source` is mapped to FHIR R4 element `DeviceDefinition.specialization` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.version",
"display": "version",
"target": [
{
"code": "DeviceDefinition.version",
"display": "DeviceDefinition.version",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.version` is mapped to FHIR R4 element `DeviceDefinition.version` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.safety",
"display": "safety",
"target": [
{
"code": "DeviceDefinition.safety",
"display": "DeviceDefinition.safety",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.safety` is mapped to FHIR R4 element `DeviceDefinition.safety` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.shelfLifeStorage",
"display": "shelfLifeStorage",
"target": [
{
"code": "DeviceDefinition.shelfLifeStorage",
"display": "DeviceDefinition.shelfLifeStorage",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.shelfLifeStorage` is mapped to FHIR R4 element `DeviceDefinition.shelfLifeStorage` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.languageCode",
"display": "languageCode",
"target": [
{
"code": "DeviceDefinition.languageCode",
"display": "DeviceDefinition.languageCode",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.languageCode` is mapped to FHIR R4 element `DeviceDefinition.languageCode` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.property",
"display": "property",
"target": [
{
"code": "DeviceDefinition.property",
"display": "DeviceDefinition.property",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.property` is mapped to FHIR R4 element `DeviceDefinition.property` as `Equivalent`.\nDynamic or current properties, such as settings, of an individual device are described using a Device instance-specific DeviceMetric and recorded using Observation. Static characteristics of an individual device could also be documented in a [Device] instance. The Device instance's properties, and their values, could be, but need not be, the same as in the associated DeviceDefinition."
}
]
},
{
"code": "DeviceDefinition.property.type",
"display": "type",
"target": [
{
"code": "DeviceDefinition.property.type",
"display": "DeviceDefinition.property.type",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.property.type` is mapped to FHIR R4 element `DeviceDefinition.property.type` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.property.value[x]",
"display": "value[x]",
"target": [
{
"code": "DeviceDefinition.property.valueCode",
"display": "DeviceDefinition.property.valueCode",
"equivalence": "relatedto",
"comment": "Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueQuantity` as `RelatedTo`.\nElement `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueCode` as `RelatedTo`.\nThe mappings for `DeviceDefinition.property.value[x]` do not cover the following types: Attachment, boolean, integer, Range, string.\nThis use of string or CodeableConcept is supported to address different purposes The text element of the valueCodeableConcept choice type is used for properties which would usually be coded (such as the size of an implant, or a security classification) but for which there is not currently an appropriate concept in the vocabulary (e.g., a custom implant size, or a security classification which depends on configuration. Otherwise the valueString choice type is used for textual descriptive device properties that cannot be expressed in other elements."
},
{
"code": "DeviceDefinition.property.valueQuantity",
"display": "DeviceDefinition.property.valueQuantity",
"equivalence": "relatedto",
"comment": "Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueQuantity` as `RelatedTo`.\nElement `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueCode` as `RelatedTo`.\nThe mappings for `DeviceDefinition.property.value[x]` do not cover the following types: Attachment, boolean, integer, Range, string.\nThis use of string or CodeableConcept is supported to address different purposes The text element of the valueCodeableConcept choice type is used for properties which would usually be coded (such as the size of an implant, or a security classification) but for which there is not currently an appropriate concept in the vocabulary (e.g., a custom implant size, or a security classification which depends on configuration. Otherwise the valueString choice type is used for textual descriptive device properties that cannot be expressed in other elements."
}
]
},
{
"code": "DeviceDefinition.owner",
"display": "owner",
"target": [
{
"code": "DeviceDefinition.owner",
"display": "DeviceDefinition.owner",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.owner` is mapped to FHIR R4 element `DeviceDefinition.owner` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.contact",
"display": "contact",
"target": [
{
"code": "DeviceDefinition.contact",
"display": "DeviceDefinition.contact",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.contact` is mapped to FHIR R4 element `DeviceDefinition.contact` as `Equivalent`.\nAn externally-defined extension that has been mapped as the representation of FHIR R5 element `DeviceDefinition.contact`: `http://hl7.org/fhir/StructureDefinition/artifact-contact`.\nused for troubleshooting etc."
}
]
},
{
"code": "DeviceDefinition.note",
"display": "note",
"target": [
{
"code": "DeviceDefinition.note",
"display": "DeviceDefinition.note",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.note` is mapped to FHIR R4 element `DeviceDefinition.note` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.material",
"display": "material",
"target": [
{
"code": "DeviceDefinition.material",
"display": "DeviceDefinition.material",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.material` is mapped to FHIR R4 element `DeviceDefinition.material` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.material.substance",
"display": "substance",
"target": [
{
"code": "DeviceDefinition.material.substance",
"display": "DeviceDefinition.material.substance",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.material.substance` is mapped to FHIR R4 element `DeviceDefinition.material.substance` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.material.alternate",
"display": "alternate",
"target": [
{
"code": "DeviceDefinition.material.alternate",
"display": "DeviceDefinition.material.alternate",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.material.alternate` is mapped to FHIR R4 element `DeviceDefinition.material.alternate` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.material.allergenicIndicator",
"display": "allergenicIndicator",
"target": [
{
"code": "DeviceDefinition.material.allergenicIndicator",
"display": "DeviceDefinition.material.allergenicIndicator",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.material.allergenicIndicator` is mapped to FHIR R4 element `DeviceDefinition.material.allergenicIndicator` as `Equivalent`."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.udiDeviceIdentifier",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.udiDeviceIdentifier",
"display": "udiDeviceIdentifier",
"target": [
{
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.deviceIdentifier",
"display": "deviceIdentifier",
"target": [
{
"code": "Extension.extension:deviceIdentifier",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.deviceIdentifier` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.deviceIdentifier` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.issuer",
"display": "issuer",
"target": [
{
"code": "Extension.extension:issuer",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.issuer` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.issuer` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.jurisdiction",
"display": "jurisdiction",
"target": [
{
"code": "Extension.extension:jurisdiction",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.jurisdiction` is mapped to FHIR R4 element `DeviceDefinition.udiDeviceIdentifier.jurisdiction` as `Equivalent`."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.marketDistribution",
"display": "marketDistribution",
"target": [
{
"code": "Extension.extension:marketDistribution",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod",
"display": "marketPeriod",
"target": [
{
"code": "Extension.extension:marketDistribution.extension:marketPeriod",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` is part of an existing definition because parent element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` requires a cross-version extension.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction",
"display": "subJurisdiction",
"target": [
{
"code": "Extension.extension:marketDistribution.extension:subJurisdiction",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` is part of an existing definition because parent element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` requires a cross-version extension.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.udiDeviceIdentifier",
"display": "udiDeviceIdentifier",
"target": [
{
"code": "Extension.extension:udiDeviceIdentifier",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.udiDeviceIdentifier` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension.\nElement `DeviceDefinition.packaging.udiDeviceIdentifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.udiDeviceIdentifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.udiDeviceIdentifier.marketDistribution",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.udiDeviceIdentifier.marketDistribution",
"display": "marketDistribution",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod",
"display": "marketPeriod",
"target": [
{
"code": "Extension.extension:marketPeriod",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` is part of an existing definition because parent element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` requires a cross-version extension.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution.marketPeriod` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction",
"display": "subJurisdiction",
"target": [
{
"code": "Extension.extension:subJurisdiction",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` is part of an existing definition because parent element `DeviceDefinition.udiDeviceIdentifier.marketDistribution` requires a cross-version extension.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` has a context of DeviceDefinition.udiDeviceIdentifier based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.udiDeviceIdentifier.marketDistribution.subJurisdiction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.regulatoryIdentifier",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.regulatoryIdentifier",
"display": "regulatoryIdentifier",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.regulatoryIdentifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.regulatoryIdentifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nThis should not be used for regulatory authorization numbers which are to be captured elsewhere."
}
]
},
{
"code": "DeviceDefinition.regulatoryIdentifier.type",
"display": "type",
"target": [
{
"code": "Extension.extension:type",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.regulatoryIdentifier.type` is part of an existing definition because parent element `DeviceDefinition.regulatoryIdentifier` requires a cross-version extension.\nElement `DeviceDefinition.regulatoryIdentifier.type` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.regulatoryIdentifier.type` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.regulatoryIdentifier.deviceIdentifier",
"display": "deviceIdentifier",
"target": [
{
"code": "Extension.extension:deviceIdentifier",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.regulatoryIdentifier.deviceIdentifier` is part of an existing definition because parent element `DeviceDefinition.regulatoryIdentifier` requires a cross-version extension.\nElement `DeviceDefinition.regulatoryIdentifier.deviceIdentifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.regulatoryIdentifier.deviceIdentifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.regulatoryIdentifier.issuer",
"display": "issuer",
"target": [
{
"code": "Extension.extension:issuer",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.regulatoryIdentifier.issuer` is part of an existing definition because parent element `DeviceDefinition.regulatoryIdentifier` requires a cross-version extension.\nElement `DeviceDefinition.regulatoryIdentifier.issuer` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.regulatoryIdentifier.issuer` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.regulatoryIdentifier.jurisdiction",
"display": "jurisdiction",
"target": [
{
"code": "Extension.extension:jurisdiction",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.regulatoryIdentifier.jurisdiction` is part of an existing definition because parent element `DeviceDefinition.regulatoryIdentifier` requires a cross-version extension.\nElement `DeviceDefinition.regulatoryIdentifier.jurisdiction` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.regulatoryIdentifier.jurisdiction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.partNumber",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.partNumber",
"display": "partNumber",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.partNumber` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.partNumber` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nAlphanumeric Maximum 20."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.classification",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.classification",
"display": "classification",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.classification` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.classification` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nIn this element various classifications can be used, such as GMDN, EMDN, SNOMED CT, risk classes, national product codes."
}
]
},
{
"code": "DeviceDefinition.classification.type",
"display": "type",
"target": [
{
"code": "Extension.extension:type",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.classification.type` is part of an existing definition because parent element `DeviceDefinition.classification` requires a cross-version extension.\nElement `DeviceDefinition.classification.type` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.classification.type` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.classification.justification",
"display": "justification",
"target": [
{
"code": "Extension.extension:justification",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.classification.justification` is part of an existing definition because parent element `DeviceDefinition.classification` requires a cross-version extension.\nElement `DeviceDefinition.classification.justification` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.classification.justification` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.hasPart",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.hasPart",
"display": "hasPart",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.hasPart` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.hasPart` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.hasPart.reference",
"display": "reference",
"target": [
{
"code": "Extension.extension:reference",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.hasPart.reference` is part of an existing definition because parent element `DeviceDefinition.hasPart` requires a cross-version extension.\nElement `DeviceDefinition.hasPart.reference` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.hasPart.reference` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.hasPart.count",
"display": "count",
"target": [
{
"code": "Extension.extension:count",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.hasPart.count` is part of an existing definition because parent element `DeviceDefinition.hasPart` requires a cross-version extension.\nElement `DeviceDefinition.hasPart.count` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.hasPart.count` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.packaging",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.packaging",
"display": "packaging",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.identifier",
"display": "identifier",
"target": [
{
"code": "Extension.extension:identifier",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.identifier` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension.\nElement `DeviceDefinition.packaging.identifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.identifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.type",
"display": "type",
"target": [
{
"code": "Extension.extension:type",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.type` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension.\nElement `DeviceDefinition.packaging.type` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.type` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.count",
"display": "count",
"target": [
{
"code": "Extension.extension:count",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.count` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension.\nElement `DeviceDefinition.packaging.count` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.count` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.distributor",
"display": "distributor",
"target": [
{
"code": "Extension.extension:distributor",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.distributor` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension.\nElement `DeviceDefinition.packaging.distributor` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.distributor` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.distributor.name",
"display": "name",
"target": [
{
"code": "Extension.extension:distributor.extension:name",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.distributor.name` is part of an existing definition because parent element `DeviceDefinition.packaging.distributor` requires a cross-version extension.\nElement `DeviceDefinition.packaging.distributor.name` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.distributor.name` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.distributor.organizationReference",
"display": "organizationReference",
"target": [
{
"code": "Extension.extension:distributor.extension:organizationReference",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.distributor.organizationReference` is part of an existing definition because parent element `DeviceDefinition.packaging.distributor` requires a cross-version extension.\nElement `DeviceDefinition.packaging.distributor.organizationReference` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.distributor.organizationReference` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.udiDeviceIdentifier",
"display": "udiDeviceIdentifier",
"target": [
{
"code": "Extension.extension:udiDeviceIdentifier",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.udiDeviceIdentifier` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension.\nElement `DeviceDefinition.packaging.udiDeviceIdentifier` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.udiDeviceIdentifier` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.packaging.packaging",
"display": "packaging",
"target": [
{
"code": "Extension.extension:packaging",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.packaging.packaging` is part of an existing definition because parent element `DeviceDefinition.packaging` requires a cross-version extension.\nElement `DeviceDefinition.packaging.packaging` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.packaging.packaging` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.version.type",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.version.type",
"display": "type",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.version.type` has a context of DeviceDefinition.version based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.version.type` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.version.component",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.version.component",
"display": "component",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.version.component` has a context of DeviceDefinition.version based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.version.component` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nNote that the module of the device would not need to be tracked as a separate device, e.g., using different UDI, thus would typically involve one or more software modules. For example, a device may involve two software modules each on a different version."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.version.value",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.version.value",
"display": "value",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.version.value` has a context of DeviceDefinition.version based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.version.value` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.property.value",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.property.value[x]",
"display": "value[x]",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueQuantity` as `RelatedTo`.\nElement `DeviceDefinition.property.value[x]` is mapped to FHIR R4 element `DeviceDefinition.property.valueCode` as `RelatedTo`.\nThe mappings for `DeviceDefinition.property.value[x]` do not cover the following types: Attachment, boolean, integer, Range, string.\nThis use of string or CodeableConcept is supported to address different purposes The text element of the valueCodeableConcept choice type is used for properties which would usually be coded (such as the size of an implant, or a security classification) but for which there is not currently an appropriate concept in the vocabulary (e.g., a custom implant size, or a security classification which depends on configuration. Otherwise the valueString choice type is used for textual descriptive device properties that cannot be expressed in other elements."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.link",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.link",
"display": "link",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.link` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.link` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.link.relation",
"display": "relation",
"target": [
{
"code": "Extension.extension:relation",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.link.relation` is part of an existing definition because parent element `DeviceDefinition.link` requires a cross-version extension.\nElement `DeviceDefinition.link.relation` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.link.relation` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.link.relatedDevice",
"display": "relatedDevice",
"target": [
{
"code": "Extension.extension:relatedDevice",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.link.relatedDevice` is part of an existing definition because parent element `DeviceDefinition.link` requires a cross-version extension.\nElement `DeviceDefinition.link.relatedDevice` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.link.relatedDevice` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.productionIdentifierInUDI",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.productionIdentifierInUDI",
"display": "productionIdentifierInUDI",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.productionIdentifierInUDI` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.productionIdentifierInUDI` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.guideline",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.guideline",
"display": "guideline",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.guideline` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.guideline` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nFor more structured data, a ClinicalUseDefinition that points to the DeviceDefinition can be used."
}
]
},
{
"code": "DeviceDefinition.guideline.useContext",
"display": "useContext",
"target": [
{
"code": "Extension.extension:useContext",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.guideline.useContext` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension.\nElement `DeviceDefinition.guideline.useContext` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.guideline.useContext` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.guideline.usageInstruction",
"display": "usageInstruction",
"target": [
{
"code": "Extension.extension:usageInstruction",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.guideline.usageInstruction` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension.\nElement `DeviceDefinition.guideline.usageInstruction` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.guideline.usageInstruction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.guideline.relatedArtifact",
"display": "relatedArtifact",
"target": [
{
"code": "Extension.extension:relatedArtifact",
"equivalence": "equivalent",
"comment": "Element `DeviceDefinition.guideline.relatedArtifact` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension.\nElement `DeviceDefinition.guideline.relatedArtifact` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.guideline.relatedArtifact` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.guideline.indication",
"display": "indication",
"target": [
{
"code": "Extension.extension:indication",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.guideline.indication` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension.\nElement `DeviceDefinition.guideline.indication` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.guideline.indication` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nA ClinicalUseDefinition that points to the DeviceDefinition can be used if more structured data is needed."
}
]
},
{
"code": "DeviceDefinition.guideline.contraindication",
"display": "contraindication",
"target": [
{
"code": "Extension.extension:contraindication",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.guideline.contraindication` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension.\nElement `DeviceDefinition.guideline.contraindication` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.guideline.contraindication` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nA ClinicalUseDefinition that points to the DeviceDefinition can be used if more structured data is needed."
}
]
},
{
"code": "DeviceDefinition.guideline.warning",
"display": "warning",
"target": [
{
"code": "Extension.extension:warning",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.guideline.warning` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension.\nElement `DeviceDefinition.guideline.warning` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.guideline.warning` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nA ClinicalUseDefinition that points to the DeviceDefinition can be used if more structured data is needed."
}
]
},
{
"code": "DeviceDefinition.guideline.intendedUse",
"display": "intendedUse",
"target": [
{
"code": "Extension.extension:intendedUse",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.guideline.intendedUse` is part of an existing definition because parent element `DeviceDefinition.guideline` requires a cross-version extension.\nElement `DeviceDefinition.guideline.intendedUse` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.guideline.intendedUse` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.correctiveAction",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.correctiveAction",
"display": "correctiveAction",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.correctiveAction` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.correctiveAction` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.correctiveAction.recall",
"display": "recall",
"target": [
{
"code": "Extension.extension:recall",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.correctiveAction.recall` is part of an existing definition because parent element `DeviceDefinition.correctiveAction` requires a cross-version extension.\nElement `DeviceDefinition.correctiveAction.recall` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.correctiveAction.recall` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element).\nWhen a field safety action has been initiated but not yet resulted in a recall, this element will be set to 'false'."
}
]
},
{
"code": "DeviceDefinition.correctiveAction.scope",
"display": "scope",
"target": [
{
"code": "Extension.extension:scope",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.correctiveAction.scope` is part of an existing definition because parent element `DeviceDefinition.correctiveAction` requires a cross-version extension.\nElement `DeviceDefinition.correctiveAction.scope` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.correctiveAction.scope` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.correctiveAction.period",
"display": "period",
"target": [
{
"code": "Extension.extension:period",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.correctiveAction.period` is part of an existing definition because parent element `DeviceDefinition.correctiveAction` requires a cross-version extension.\nElement `DeviceDefinition.correctiveAction.period` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.correctiveAction.period` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/DeviceDefinition",
"sourceVersion": "5.0.0",
"target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceDefinition.chargeItem",
"targetVersion": "0.1.0",
"element": [
{
"code": "DeviceDefinition.chargeItem",
"display": "chargeItem",
"target": [
{
"code": "Extension",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.chargeItem` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.chargeItem` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.chargeItem.chargeItemCode",
"display": "chargeItemCode",
"target": [
{
"code": "Extension.extension:chargeItemCode",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.chargeItem.chargeItemCode` is part of an existing definition because parent element `DeviceDefinition.chargeItem` requires a cross-version extension.\nElement `DeviceDefinition.chargeItem.chargeItemCode` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.chargeItem.chargeItemCode` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.chargeItem.count",
"display": "count",
"target": [
{
"code": "Extension.extension:count",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.chargeItem.count` is part of an existing definition because parent element `DeviceDefinition.chargeItem` requires a cross-version extension.\nElement `DeviceDefinition.chargeItem.count` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.chargeItem.count` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.chargeItem.effectivePeriod",
"display": "effectivePeriod",
"target": [
{
"code": "Extension.extension:effectivePeriod",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.chargeItem.effectivePeriod` is part of an existing definition because parent element `DeviceDefinition.chargeItem` requires a cross-version extension.\nElement `DeviceDefinition.chargeItem.effectivePeriod` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.chargeItem.effectivePeriod` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "DeviceDefinition.chargeItem.useContext",
"display": "useContext",
"target": [
{
"code": "Extension.extension:useContext",
"equivalence": "wider",
"comment": "Element `DeviceDefinition.chargeItem.useContext` is part of an existing definition because parent element `DeviceDefinition.chargeItem` requires a cross-version extension.\nElement `DeviceDefinition.chargeItem.useContext` has a context of DeviceDefinition based on following the parent source element upwards and mapping to `DeviceDefinition`.\nElement `DeviceDefinition.chargeItem.useContext` has no mapping targets in FHIR R4. Typically, this is because the element has been added (is a new element)."
}
]
}
]
}
]
}