FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r5.r3
Resource TypeConceptMap
IdConceptMap-R5-ImagingStudy-element-map-to-R3.json
FHIR VersionR3
Sourcehttp://hl7.org/fhir/uv/xver-r5.r3/0.1.0/ConceptMap-R5-ImagingStudy-element-map-to-R3.html
URLhttp://hl7.org/fhir/uv/xver/ConceptMap/R5-ImagingStudy-element-map-to-R3
Version0.1.0
Statusactive
Date2026-03-17T16:05:17.3061093-05:00
NameR5ImagingStudyElementMapToR3
TitleCross-version mapping for FHIR R5 ImagingStudy to FHIR STU3 ImagingStudy
Realmuv
Authorityhl7
DescriptionThis ConceptMap represents cross-version mappings for elements from a FHIR R5 ImagingStudy to FHIR STU3.

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
hl7.fhir.uv.xver-r5.r3#0.1.0extension-ImagingStudy.locationR5: Where ImagingStudy occurred (new)
hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2extension-ImagingStudy.modalityCross-version Extension for R5.ImagingStudy.modality for use in FHIR R4
hl7.fhir.uv.xver-r5.r3#0.1.0extension-ImagingStudy.noteR5: User-defined comments (new)
hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2extension-ImagingStudy.partOfCross-version Extension for R5.ImagingStudy.partOf for use in FHIR R4
hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2extension-ImagingStudy.reasonCross-version Extension for R5.ImagingStudy.reason for use in FHIR R4
hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2extension-ImagingStudy.series.bodySiteCross-version Extension for R5.ImagingStudy.series.bodySite for use in FHIR R4
hl7.fhir.uv.xver-r5.r3#0.1.0extension-ImagingStudy.series.instance.sopClassR5: sopClass additional types
hl7.fhir.uv.xver-r5.r3#0.1.0extension-ImagingStudy.series.instance.uidR5: DICOM SOP Instance UID additional types
hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2extension-ImagingStudy.series.lateralityCross-version Extension for R5.ImagingStudy.series.laterality for use in FHIR R4
hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2extension-ImagingStudy.series.modalityCross-version Extension for R5.ImagingStudy.series.modality for use in FHIR R4
hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2extension-ImagingStudy.series.performer.actorCross-version Extension for R5.ImagingStudy.series.performer.actor for use in FHIR R4
hl7.fhir.uv.xver-r5.r3#0.1.0extension-ImagingStudy.series.performer.functionR5: Type of performance (new)
hl7.fhir.uv.xver-r5.r3#0.1.0extension-ImagingStudy.series.specimenR5: Specimen imaged (new)
hl7.fhir.uv.xver-r5.r3#0.1.0extension-ImagingStudy.series.uidR5: DICOM Series Instance UID for the series additional types

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap R5-ImagingStudy-element-map-to-R3

Mapping from http://hl7.org/fhir/5.0 to http://hl7.org/fhir/3.0


Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to http://hl7.org/fhir/StructureDefinition/ImagingStudy|3.0.2

Source Concept DetailsRelationshipTarget Concept DetailsComment
Codes from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0Codes from http://hl7.org/fhir/StructureDefinition/ImagingStudy|3.0.2
ImagingStudy.metametais equivalent toImagingStudy.metaImagingStudy.metaElement `ImagingStudy.meta` is mapped to FHIR STU3 element `ImagingStudy.meta` as `Equivalent`.
ImagingStudy.implicitRulesimplicitRulesis equivalent toImagingStudy.implicitRulesImagingStudy.implicitRulesElement `ImagingStudy.implicitRules` is mapped to FHIR STU3 element `ImagingStudy.implicitRules` as `Equivalent`. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc.
ImagingStudy.languagelanguageis equivalent toImagingStudy.languageImagingStudy.languageElement `ImagingStudy.language` is mapped to FHIR STU3 element `ImagingStudy.language` as `Equivalent`. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).
ImagingStudy.texttextis equivalent toImagingStudy.textImagingStudy.textElement `ImagingStudy.text` is mapped to FHIR STU3 element `ImagingStudy.text` as `Equivalent`. Contained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.
ImagingStudy.containedcontainedis equivalent toImagingStudy.containedImagingStudy.containedElement `ImagingStudy.contained` is mapped to FHIR STU3 element `ImagingStudy.contained` as `SourceIsBroaderThanTarget`. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels.
ImagingStudy.identifieridentifieris related toImagingStudy.accessionImagingStudy.accessionElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`. See discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID.
is equivalent toImagingStudy.identifierImagingStudy.identifierElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`. See discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID.
is related toImagingStudy.uidImagingStudy.uidElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`. See discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID.
ImagingStudy.statusstatusis equivalent toImagingStudy.availabilityImagingStudy.availabilityElement `ImagingStudy.status` is mapped to FHIR STU3 element `ImagingStudy.availability` as `Equivalent`. Unknown does not represent "other" - one of the defined statuses must apply. Unknown is used when the authoring system is not sure what the current status is.
ImagingStudy.modalitymodalitymaps to wider conceptImagingStudy.modalityListImagingStudy.modalityListElement `ImagingStudy.modality` is mapped to FHIR STU3 element `ImagingStudy.modalityList` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.modality` do not cover the following types: CodeableConcept. The mappings for `ImagingStudy.modality` do not cover the following types based on type expansion: text.
ImagingStudy.subjectsubjectmaps to wider conceptImagingStudy.patientImagingStudy.patientElement `ImagingStudy.subject` is mapped to FHIR STU3 element `ImagingStudy.patient` as `SourceIsBroaderThanTarget`. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.subject` with unmapped reference targets: Device, Group, Patient. QA phantoms can be recorded with a Device; multiple subjects (such as mice) can be recorded with a Group.
ImagingStudy.encounterencountermaps to wider conceptImagingStudy.contextImagingStudy.contextElement `ImagingStudy.encounter` is mapped to FHIR STU3 element `ImagingStudy.context` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.encounter` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.encounter` with unmapped reference targets: Encounter. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission test).
ImagingStudy.startedstartedis equivalent toImagingStudy.startedImagingStudy.startedElement `ImagingStudy.started` is mapped to FHIR STU3 element `ImagingStudy.started` as `Equivalent`.
ImagingStudy.basedOnbasedOnmaps to wider conceptImagingStudy.basedOnImagingStudy.basedOnElement `ImagingStudy.basedOn` is mapped to FHIR STU3 element `ImagingStudy.basedOn` as `SourceIsBroaderThanTarget`. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.basedOn` with unmapped reference targets: Appointment, AppointmentResponse, CarePlan, ServiceRequest, Task.
ImagingStudy.referrerreferrermaps to wider conceptImagingStudy.referrerImagingStudy.referrerElement `ImagingStudy.referrer` is mapped to FHIR STU3 element `ImagingStudy.referrer` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.referrer` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.referrer` with unmapped reference targets: Practitioner, PractitionerRole.
ImagingStudy.endpointendpointmaps to wider conceptImagingStudy.endpointImagingStudy.endpointElement `ImagingStudy.endpoint` is mapped to FHIR STU3 element `ImagingStudy.endpoint` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.endpoint` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.endpoint` with unmapped reference targets: Endpoint. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG), formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances; or IHE Invoke Image Display (IID), which provides standard invocation of an imaging web viewer.
ImagingStudy.numberOfSeriesnumberOfSeriesis equivalent toImagingStudy.numberOfSeriesImagingStudy.numberOfSeriesElement `ImagingStudy.numberOfSeries` is mapped to FHIR STU3 element `ImagingStudy.numberOfSeries` as `Equivalent`.
ImagingStudy.numberOfInstancesnumberOfInstancesis equivalent toImagingStudy.numberOfInstancesImagingStudy.numberOfInstancesElement `ImagingStudy.numberOfInstances` is mapped to FHIR STU3 element `ImagingStudy.numberOfInstances` as `Equivalent`.
ImagingStudy.procedureprocedureis related toImagingStudy.procedureCodeImagingStudy.procedureCodeElement `ImagingStudy.procedure` is mapped to FHIR STU3 element `ImagingStudy.procedureReference` as `RelatedTo`. Element `ImagingStudy.procedure` is mapped to FHIR STU3 element `ImagingStudy.procedureCode` as `SourceIsBroaderThanTarget`.
is related toImagingStudy.procedureReferenceImagingStudy.procedureReferenceElement `ImagingStudy.procedure` is mapped to FHIR STU3 element `ImagingStudy.procedureReference` as `RelatedTo`. Element `ImagingStudy.procedure` is mapped to FHIR STU3 element `ImagingStudy.procedureCode` as `SourceIsBroaderThanTarget`.
ImagingStudy.reasonreasonis related toImagingStudy.reasonImagingStudy.reasonElement `ImagingStudy.reason` is mapped to FHIR STU3 element `ImagingStudy.reason` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.reason` do not cover the following types: CodeableReference.
ImagingStudy.descriptiondescriptionis equivalent toImagingStudy.descriptionImagingStudy.descriptionElement `ImagingStudy.description` is mapped to FHIR STU3 element `ImagingStudy.description` as `Equivalent`.
ImagingStudy.seriesseriesmaps to wider conceptImagingStudy.seriesImagingStudy.seriesElement `ImagingStudy.series` is mapped to FHIR STU3 element `ImagingStudy.series` as `Equivalent`.
ImagingStudy.series.uiduidmaps to wider conceptImagingStudy.series.uidImagingStudy.series.uidElement `ImagingStudy.series.uid` is mapped to FHIR STU3 element `ImagingStudy.series.uid` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.uid` do not cover the following types: id. The mappings for `ImagingStudy.series.uid` do not cover the following types based on type expansion: value. See [DICOM PS3.3 C.7.3](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.7.3.html).
ImagingStudy.series.numbernumberis equivalent toImagingStudy.series.numberImagingStudy.series.numberElement `ImagingStudy.series.number` is mapped to FHIR STU3 element `ImagingStudy.series.number` as `Equivalent`.
ImagingStudy.series.modalitymodalitymaps to wider conceptImagingStudy.series.modalityImagingStudy.series.modalityElement `ImagingStudy.series.modality` is mapped to FHIR STU3 element `ImagingStudy.series.modality` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.modality` do not cover the following types: CodeableConcept. The mappings for `ImagingStudy.series.modality` do not cover the following types based on type expansion: text.
ImagingStudy.series.descriptiondescriptionis equivalent toImagingStudy.series.descriptionImagingStudy.series.descriptionElement `ImagingStudy.series.description` is mapped to FHIR STU3 element `ImagingStudy.series.description` as `Equivalent`.
ImagingStudy.series.numberOfInstancesnumberOfInstancesis equivalent toImagingStudy.series.numberOfInstancesImagingStudy.series.numberOfInstancesElement `ImagingStudy.series.numberOfInstances` is mapped to FHIR STU3 element `ImagingStudy.series.numberOfInstances` as `Equivalent`.
ImagingStudy.series.endpointendpointmaps to wider conceptImagingStudy.series.endpointImagingStudy.series.endpointElement `ImagingStudy.series.endpoint` is mapped to FHIR STU3 element `ImagingStudy.series.endpoint` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.endpoint` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.series.endpoint` with unmapped reference targets: Endpoint. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; and DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances.
ImagingStudy.series.bodySitebodySitemaps to wider conceptImagingStudy.series.bodySiteImagingStudy.series.bodySiteElement `ImagingStudy.series.bodySite` is mapped to FHIR STU3 element `ImagingStudy.series.bodySite` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.bodySite` do not cover the following types: CodeableReference. The mappings for `ImagingStudy.series.bodySite` do not cover the following types based on type expansion: concept, reference.
ImagingStudy.series.lateralitylateralitymaps to wider conceptImagingStudy.series.lateralityImagingStudy.series.lateralityElement `ImagingStudy.series.laterality` is mapped to FHIR STU3 element `ImagingStudy.series.laterality` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.laterality` do not cover the following types: CodeableConcept. The mappings for `ImagingStudy.series.laterality` do not cover the following types based on type expansion: text.
ImagingStudy.series.startedstartedis equivalent toImagingStudy.series.startedImagingStudy.series.startedElement `ImagingStudy.series.started` is mapped to FHIR STU3 element `ImagingStudy.series.started` as `Equivalent`.
ImagingStudy.series.performerperformermaps to wider conceptImagingStudy.series.performerImagingStudy.series.performerElement `ImagingStudy.series.performer` is mapped to FHIR STU3 element `ImagingStudy.series.performer` as `Equivalent`. If the person who performed the series is not known, their Organization may be recorded. A patient, or related person, may be the performer, e.g. for patient-captured images.
ImagingStudy.series.instanceinstancemaps to wider conceptImagingStudy.series.instanceImagingStudy.series.instanceElement `ImagingStudy.series.instance` is mapped to FHIR STU3 element `ImagingStudy.series.instance` as `Equivalent`.
ImagingStudy.series.instance.uiduidmaps to wider conceptImagingStudy.series.instance.uidImagingStudy.series.instance.uidElement `ImagingStudy.series.instance.uid` is mapped to FHIR STU3 element `ImagingStudy.series.instance.uid` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.instance.uid` do not cover the following types: id. The mappings for `ImagingStudy.series.instance.uid` do not cover the following types based on type expansion: value. See [DICOM PS3.3 C.12.1](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.12.html#sect_C.12.1).
ImagingStudy.series.instance.sopClasssopClassmaps to wider conceptImagingStudy.series.instance.sopClassImagingStudy.series.instance.sopClassElement `ImagingStudy.series.instance.sopClass` is mapped to FHIR STU3 element `ImagingStudy.series.instance.sopClass` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types: Coding. The mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types based on type expansion: code, display, system, userSelected, version.
ImagingStudy.series.instance.numbernumberis equivalent toImagingStudy.series.instance.numberImagingStudy.series.instance.numberElement `ImagingStudy.series.instance.number` is mapped to FHIR STU3 element `ImagingStudy.series.instance.number` as `Equivalent`.
ImagingStudy.series.instance.titletitleis equivalent toImagingStudy.series.instance.titleImagingStudy.series.instance.titleElement `ImagingStudy.series.instance.title` is mapped to FHIR STU3 element `ImagingStudy.series.instance.title` as `Equivalent`. Particularly for post-acquisition analytic objects, such as SR, presentation states, value mapping, etc.

Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: All of the distinct values for series' modalities additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.modality (modality)maps to wider conceptExtension (R5: All of the distinct values for series' modalities additional types)Element `ImagingStudy.modality` is mapped to FHIR STU3 element `ImagingStudy.modalityList` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.modality` do not cover the following types: CodeableConcept. The mappings for `ImagingStudy.modality` do not cover the following types based on type expansion: text.

Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: Part of referenced event (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.partOf (partOf)maps to wider conceptExtension (R5: Part of referenced event (new))Element `ImagingStudy.partOf` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.partOf` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). To link an ImagingStudy to an Encounter use `encounter`.

Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: Where ImagingStudy occurred (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.location (location)is equivalent toExtension (R5: Where ImagingStudy occurred (new))Element `ImagingStudy.location` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.location` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: Why the study was requested / performed additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.reason (reason)maps to wider conceptExtension (R5: Why the study was requested / performed additional types)Element `ImagingStudy.reason` is mapped to FHIR STU3 element `ImagingStudy.reason` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.reason` do not cover the following types: CodeableReference.

Group 6 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: User-defined comments (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.note (note)is equivalent toExtension (R5: User-defined comments (new))Element `ImagingStudy.note` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.note` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 7 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: DICOM Series Instance UID for the series additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.uid (uid)is equivalent toExtension (R5: DICOM Series Instance UID for the series additional types)Element `ImagingStudy.series.uid` is mapped to FHIR STU3 element `ImagingStudy.series.uid` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.uid` do not cover the following types: id. The mappings for `ImagingStudy.series.uid` do not cover the following types based on type expansion: value. See [DICOM PS3.3 C.7.3](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.7.3.html).

Group 8 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: The modality used for this series additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.modality (modality)is equivalent toExtension (R5: The modality used for this series additional types)Element `ImagingStudy.series.modality` is mapped to FHIR STU3 element `ImagingStudy.series.modality` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.modality` do not cover the following types: CodeableConcept. The mappings for `ImagingStudy.series.modality` do not cover the following types based on type expansion: text.

Group 9 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: bodySite additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.bodySite (bodySite)is equivalent toExtension (R5: bodySite additional types)Element `ImagingStudy.series.bodySite` is mapped to FHIR STU3 element `ImagingStudy.series.bodySite` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.bodySite` do not cover the following types: CodeableReference. The mappings for `ImagingStudy.series.bodySite` do not cover the following types based on type expansion: concept, reference.

Group 10 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: laterality additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.laterality (laterality)is equivalent toExtension (R5: laterality additional types)Element `ImagingStudy.series.laterality` is mapped to FHIR STU3 element `ImagingStudy.series.laterality` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.laterality` do not cover the following types: CodeableConcept. The mappings for `ImagingStudy.series.laterality` do not cover the following types based on type expansion: text.

Group 11 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: Specimen imaged (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.specimen (specimen)is equivalent toExtension (R5: Specimen imaged (new))Element `ImagingStudy.series.specimen` has a context of ImagingStudy.series based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.series.specimen` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 12 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: Type of performance (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.performer.function (function)is equivalent toExtension (R5: Type of performance (new))Element `ImagingStudy.series.performer.function` has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.series.performer.function` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 13 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: Who performed the series (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.performer.actor (actor)maps to wider conceptExtension (R5: Who performed the series (new))Element `ImagingStudy.series.performer.actor` has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.series.performer.actor` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 14 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: DICOM SOP Instance UID additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.instance.uid (uid)is equivalent toExtension (R5: DICOM SOP Instance UID additional types)Element `ImagingStudy.series.instance.uid` is mapped to FHIR STU3 element `ImagingStudy.series.instance.uid` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.instance.uid` do not cover the following types: id. The mappings for `ImagingStudy.series.instance.uid` do not cover the following types based on type expansion: value. See [DICOM PS3.3 C.12.1](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.12.html#sect_C.12.1).

Group 15 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|5.0.0 to R5: sopClass additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.instance.sopClass (sopClass)is equivalent toExtension (R5: sopClass additional types)Element `ImagingStudy.series.instance.sopClass` is mapped to FHIR STU3 element `ImagingStudy.series.instance.sopClass` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types: Coding. The mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types based on type expansion: code, display, system, userSelected, version.

Source1

{
  "resourceType": "ConceptMap",
  "id": "R5-ImagingStudy-element-map-to-R3",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r5.r3"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r5.r3"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ConceptMap/R5-ImagingStudy-element-map-to-R3",
  "version": "0.1.0",
  "name": "R5ImagingStudyElementMapToR3",
  "title": "Cross-version mapping for FHIR R5 ImagingStudy to FHIR STU3 ImagingStudy",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T16:05:17.3061093-05:00",
  "contact": [
    {
      "name": "FHIR Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "This ConceptMap represents cross-version mappings for elements from a FHIR R5 ImagingStudy to FHIR STU3.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "sourceUri": "http://hl7.org/fhir/5.0",
  "targetUri": "http://hl7.org/fhir/3.0",
  "group": [
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "targetVersion": "3.0.2",
      "element": [
        {
          "code": "ImagingStudy.meta",
          "display": "meta",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.meta",
              "display": "ImagingStudy.meta",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.meta` is mapped to FHIR STU3 element `ImagingStudy.meta` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.implicitRules",
          "display": "implicitRules",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.implicitRules",
              "display": "ImagingStudy.implicitRules",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.implicitRules` is mapped to FHIR STU3 element `ImagingStudy.implicitRules` as `Equivalent`.\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc."
            }
          ]
        },
        {
          "code": "ImagingStudy.language",
          "display": "language",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.language",
              "display": "ImagingStudy.language",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.language` is mapped to FHIR STU3 element `ImagingStudy.language` as `Equivalent`.\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
            }
          ]
        },
        {
          "code": "ImagingStudy.text",
          "display": "text",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.text",
              "display": "ImagingStudy.text",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.text` is mapped to FHIR STU3 element `ImagingStudy.text` as `Equivalent`.\nContained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied).  This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
            }
          ]
        },
        {
          "code": "ImagingStudy.contained",
          "display": "contained",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.contained",
              "display": "ImagingStudy.contained",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.contained` is mapped to FHIR STU3 element `ImagingStudy.contained` as `SourceIsBroaderThanTarget`.\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels."
            }
          ]
        },
        {
          "code": "ImagingStudy.identifier",
          "display": "identifier",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "ImagingStudy.accession",
              "display": "ImagingStudy.accession",
              "equivalence": "relatedto",
              "comment": "Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`.\nSee discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID."
            },
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.identifier",
              "display": "ImagingStudy.identifier",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`.\nSee discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID."
            },
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "ImagingStudy.uid",
              "display": "ImagingStudy.uid",
              "equivalence": "relatedto",
              "comment": "Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`.\nSee discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID."
            }
          ]
        },
        {
          "code": "ImagingStudy.status",
          "display": "status",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.availability",
              "display": "ImagingStudy.availability",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.status` is mapped to FHIR STU3 element `ImagingStudy.availability` as `Equivalent`.\nUnknown does not represent \"other\" - one of the defined statuses must apply.  Unknown is used when the authoring system is not sure what the current status is."
            }
          ]
        },
        {
          "code": "ImagingStudy.modality",
          "display": "modality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.modalityList",
              "display": "ImagingStudy.modalityList",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.modality` is mapped to FHIR STU3 element `ImagingStudy.modalityList` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.modality` do not cover the following types: CodeableConcept.\nThe mappings for `ImagingStudy.modality` do not cover the following types based on type expansion: text."
            }
          ]
        },
        {
          "code": "ImagingStudy.subject",
          "display": "subject",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.patient",
              "display": "ImagingStudy.patient",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.subject` is mapped to FHIR STU3 element `ImagingStudy.patient` as `SourceIsBroaderThanTarget`.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.subject` with unmapped reference targets: Device, Group, Patient.\nQA phantoms can be recorded with a Device; multiple subjects (such as mice) can be recorded with a Group."
            }
          ]
        },
        {
          "code": "ImagingStudy.encounter",
          "display": "encounter",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.context",
              "display": "ImagingStudy.context",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.encounter` is mapped to FHIR STU3 element `ImagingStudy.context` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.encounter` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.encounter` with unmapped reference targets: Encounter.\nThis will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission test)."
            }
          ]
        },
        {
          "code": "ImagingStudy.started",
          "display": "started",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.started",
              "display": "ImagingStudy.started",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.started` is mapped to FHIR STU3 element `ImagingStudy.started` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.basedOn",
          "display": "basedOn",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.basedOn",
              "display": "ImagingStudy.basedOn",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.basedOn` is mapped to FHIR STU3 element `ImagingStudy.basedOn` as `SourceIsBroaderThanTarget`.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.basedOn` with unmapped reference targets: Appointment, AppointmentResponse, CarePlan, ServiceRequest, Task."
            }
          ]
        },
        {
          "code": "ImagingStudy.referrer",
          "display": "referrer",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.referrer",
              "display": "ImagingStudy.referrer",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.referrer` is mapped to FHIR STU3 element `ImagingStudy.referrer` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.referrer` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.referrer` with unmapped reference targets: Practitioner, PractitionerRole."
            }
          ]
        },
        {
          "code": "ImagingStudy.endpoint",
          "display": "endpoint",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.endpoint",
              "display": "ImagingStudy.endpoint",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.endpoint` is mapped to FHIR STU3 element `ImagingStudy.endpoint` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.endpoint` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.endpoint` with unmapped reference targets: Endpoint.\nTypical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG), formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances; or IHE Invoke Image Display (IID), which provides standard invocation of an imaging web viewer."
            }
          ]
        },
        {
          "code": "ImagingStudy.numberOfSeries",
          "display": "numberOfSeries",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.numberOfSeries",
              "display": "ImagingStudy.numberOfSeries",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.numberOfSeries` is mapped to FHIR STU3 element `ImagingStudy.numberOfSeries` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.numberOfInstances",
          "display": "numberOfInstances",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.numberOfInstances",
              "display": "ImagingStudy.numberOfInstances",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.numberOfInstances` is mapped to FHIR STU3 element `ImagingStudy.numberOfInstances` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.procedure",
          "display": "procedure",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "ImagingStudy.procedureCode",
              "display": "ImagingStudy.procedureCode",
              "equivalence": "relatedto",
              "comment": "Element `ImagingStudy.procedure` is mapped to FHIR STU3 element `ImagingStudy.procedureReference` as `RelatedTo`.\nElement `ImagingStudy.procedure` is mapped to FHIR STU3 element `ImagingStudy.procedureCode` as `SourceIsBroaderThanTarget`."
            },
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "ImagingStudy.procedureReference",
              "display": "ImagingStudy.procedureReference",
              "equivalence": "relatedto",
              "comment": "Element `ImagingStudy.procedure` is mapped to FHIR STU3 element `ImagingStudy.procedureReference` as `RelatedTo`.\nElement `ImagingStudy.procedure` is mapped to FHIR STU3 element `ImagingStudy.procedureCode` as `SourceIsBroaderThanTarget`."
            }
          ]
        },
        {
          "code": "ImagingStudy.reason",
          "display": "reason",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "ImagingStudy.reason",
              "display": "ImagingStudy.reason",
              "equivalence": "relatedto",
              "comment": "Element `ImagingStudy.reason` is mapped to FHIR STU3 element `ImagingStudy.reason` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.reason` do not cover the following types: CodeableReference."
            }
          ]
        },
        {
          "code": "ImagingStudy.description",
          "display": "description",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.description",
              "display": "ImagingStudy.description",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.description` is mapped to FHIR STU3 element `ImagingStudy.description` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series",
          "display": "series",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series",
              "display": "ImagingStudy.series",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series` is mapped to FHIR STU3 element `ImagingStudy.series` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.uid",
              "display": "ImagingStudy.series.uid",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.uid` is mapped to FHIR STU3 element `ImagingStudy.series.uid` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.uid` do not cover the following types: id.\nThe mappings for `ImagingStudy.series.uid` do not cover the following types based on type expansion: value.\nSee [DICOM PS3.3 C.7.3](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.7.3.html)."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.number",
          "display": "number",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.number",
              "display": "ImagingStudy.series.number",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.number` is mapped to FHIR STU3 element `ImagingStudy.series.number` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.modality",
          "display": "modality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.modality",
              "display": "ImagingStudy.series.modality",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.modality` is mapped to FHIR STU3 element `ImagingStudy.series.modality` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.modality` do not cover the following types: CodeableConcept.\nThe mappings for `ImagingStudy.series.modality` do not cover the following types based on type expansion: text."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.description",
          "display": "description",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.description",
              "display": "ImagingStudy.series.description",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.description` is mapped to FHIR STU3 element `ImagingStudy.series.description` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.numberOfInstances",
          "display": "numberOfInstances",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.numberOfInstances",
              "display": "ImagingStudy.series.numberOfInstances",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.numberOfInstances` is mapped to FHIR STU3 element `ImagingStudy.series.numberOfInstances` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.endpoint",
          "display": "endpoint",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.endpoint",
              "display": "ImagingStudy.series.endpoint",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.endpoint` is mapped to FHIR STU3 element `ImagingStudy.series.endpoint` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.endpoint` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `ImagingStudy.series.endpoint` with unmapped reference targets: Endpoint.\nTypical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; and DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.bodySite",
          "display": "bodySite",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.bodySite",
              "display": "ImagingStudy.series.bodySite",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.bodySite` is mapped to FHIR STU3 element `ImagingStudy.series.bodySite` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.bodySite` do not cover the following types: CodeableReference.\nThe mappings for `ImagingStudy.series.bodySite` do not cover the following types based on type expansion: concept, reference."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.laterality",
          "display": "laterality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.laterality",
              "display": "ImagingStudy.series.laterality",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.laterality` is mapped to FHIR STU3 element `ImagingStudy.series.laterality` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.laterality` do not cover the following types: CodeableConcept.\nThe mappings for `ImagingStudy.series.laterality` do not cover the following types based on type expansion: text."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.started",
          "display": "started",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.started",
              "display": "ImagingStudy.series.started",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.started` is mapped to FHIR STU3 element `ImagingStudy.series.started` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.performer",
          "display": "performer",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.performer",
              "display": "ImagingStudy.series.performer",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.performer` is mapped to FHIR STU3 element `ImagingStudy.series.performer` as `Equivalent`.\nIf the person who performed the series is not known, their Organization may be recorded. A patient, or related person, may be the performer, e.g. for patient-captured images."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance",
          "display": "instance",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.instance",
              "display": "ImagingStudy.series.instance",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.instance` is mapped to FHIR STU3 element `ImagingStudy.series.instance` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.instance.uid",
              "display": "ImagingStudy.series.instance.uid",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.instance.uid` is mapped to FHIR STU3 element `ImagingStudy.series.instance.uid` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.instance.uid` do not cover the following types: id.\nThe mappings for `ImagingStudy.series.instance.uid` do not cover the following types based on type expansion: value.\nSee  [DICOM PS3.3 C.12.1](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.12.html#sect_C.12.1)."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance.sopClass",
          "display": "sopClass",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.instance.sopClass",
              "display": "ImagingStudy.series.instance.sopClass",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.instance.sopClass` is mapped to FHIR STU3 element `ImagingStudy.series.instance.sopClass` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types: Coding.\nThe mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types based on type expansion: code, display, system, userSelected, version."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance.number",
          "display": "number",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.instance.number",
              "display": "ImagingStudy.series.instance.number",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.instance.number` is mapped to FHIR STU3 element `ImagingStudy.series.instance.number` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance.title",
          "display": "title",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.instance.title",
              "display": "ImagingStudy.series.instance.title",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.instance.title` is mapped to FHIR STU3 element `ImagingStudy.series.instance.title` as `Equivalent`.\nParticularly for post-acquisition analytic objects, such as SR, presentation states, value mapping, etc."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.modality",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.modality",
          "display": "modality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.modality` is mapped to FHIR STU3 element `ImagingStudy.modalityList` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.modality` do not cover the following types: CodeableConcept.\nThe mappings for `ImagingStudy.modality` do not cover the following types based on type expansion: text."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.partOf",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.partOf",
          "display": "partOf",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.partOf` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.partOf` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nTo link an ImagingStudy to an Encounter use `encounter`."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.location",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.location",
          "display": "location",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.location` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.location` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.reason",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.reason",
          "display": "reason",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.reason` is mapped to FHIR STU3 element `ImagingStudy.reason` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.reason` do not cover the following types: CodeableReference."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.note",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.note",
          "display": "note",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.note` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.note` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.uid",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.uid` is mapped to FHIR STU3 element `ImagingStudy.series.uid` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.uid` do not cover the following types: id.\nThe mappings for `ImagingStudy.series.uid` do not cover the following types based on type expansion: value.\nSee [DICOM PS3.3 C.7.3](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.7.3.html)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.modality",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.modality",
          "display": "modality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.modality` is mapped to FHIR STU3 element `ImagingStudy.series.modality` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.modality` do not cover the following types: CodeableConcept.\nThe mappings for `ImagingStudy.series.modality` do not cover the following types based on type expansion: text."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.bodySite",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.bodySite",
          "display": "bodySite",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.bodySite` is mapped to FHIR STU3 element `ImagingStudy.series.bodySite` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.bodySite` do not cover the following types: CodeableReference.\nThe mappings for `ImagingStudy.series.bodySite` do not cover the following types based on type expansion: concept, reference."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.laterality",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.laterality",
          "display": "laterality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.laterality` is mapped to FHIR STU3 element `ImagingStudy.series.laterality` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.laterality` do not cover the following types: CodeableConcept.\nThe mappings for `ImagingStudy.series.laterality` do not cover the following types based on type expansion: text."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.specimen",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.specimen",
          "display": "specimen",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.specimen` has a context of ImagingStudy.series based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.series.specimen` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.performer.function",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.performer.function",
          "display": "function",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.performer.function` has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.series.performer.function` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.performer.actor",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.performer.actor",
          "display": "actor",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.performer.actor` has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.series.performer.actor` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.instance.uid",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.instance.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.instance.uid` is mapped to FHIR STU3 element `ImagingStudy.series.instance.uid` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.instance.uid` do not cover the following types: id.\nThe mappings for `ImagingStudy.series.instance.uid` do not cover the following types based on type expansion: value.\nSee  [DICOM PS3.3 C.12.1](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.12.html#sect_C.12.1)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-ImagingStudy.series.instance.sopClass",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.instance.sopClass",
          "display": "sopClass",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.instance.sopClass` is mapped to FHIR STU3 element `ImagingStudy.series.instance.sopClass` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types: Coding.\nThe mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types based on type expansion: code, display, system, userSelected, version."
            }
          ]
        }
      ]
    }
  ]
}