FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r5.r3
Resource TypeConceptMap
IdConceptMap-R5-DeviceMetric-element-map-to-R3.json
FHIR VersionR3
Sourcehttp://hl7.org/fhir/uv/xver-r5.r3/0.1.0/ConceptMap-R5-DeviceMetric-element-map-to-R3.html
URLhttp://hl7.org/fhir/uv/xver/ConceptMap/R5-DeviceMetric-element-map-to-R3
Version0.1.0
Statusactive
Date2026-03-17T16:05:15.6062504-05:00
NameR5DeviceMetricElementMapToR3
TitleCross-version mapping for FHIR R5 DeviceMetric to FHIR STU3 DeviceMetric
Realmuv
Authorityhl7
DescriptionThis ConceptMap represents cross-version mappings for elements from a FHIR R5 DeviceMetric to FHIR STU3.

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
hl7.fhir.uv.xver-r5.r4.r4#0.0.1-snapshot-2extension-DeviceMetric.measurementFrequencyCross-version Extension for R5.DeviceMetric.measurementFrequency for use in FHIR R4

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap R5-DeviceMetric-element-map-to-R3

Mapping from http://hl7.org/fhir/5.0 to http://hl7.org/fhir/3.0


Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|5.0.0 to http://hl7.org/fhir/StructureDefinition/DeviceMetric|3.0.2

Source Concept DetailsRelationshipTarget Concept DetailsComment
Codes from http://hl7.org/fhir/StructureDefinition/DeviceMetric|5.0.0Codes from http://hl7.org/fhir/StructureDefinition/DeviceMetric|3.0.2
DeviceMetric.metametais equivalent toDeviceMetric.metaDeviceMetric.metaElement `DeviceMetric.meta` is mapped to FHIR STU3 element `DeviceMetric.meta` as `Equivalent`.
DeviceMetric.implicitRulesimplicitRulesis equivalent toDeviceMetric.implicitRulesDeviceMetric.implicitRulesElement `DeviceMetric.implicitRules` is mapped to FHIR STU3 element `DeviceMetric.implicitRules` as `Equivalent`. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc.
DeviceMetric.languagelanguageis equivalent toDeviceMetric.languageDeviceMetric.languageElement `DeviceMetric.language` is mapped to FHIR STU3 element `DeviceMetric.language` as `Equivalent`. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).
DeviceMetric.texttextis equivalent toDeviceMetric.textDeviceMetric.textElement `DeviceMetric.text` is mapped to FHIR STU3 element `DeviceMetric.text` as `Equivalent`. Contained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.
DeviceMetric.containedcontainedis equivalent toDeviceMetric.containedDeviceMetric.containedElement `DeviceMetric.contained` is mapped to FHIR STU3 element `DeviceMetric.contained` as `SourceIsBroaderThanTarget`. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels.
DeviceMetric.identifieridentifieris equivalent toDeviceMetric.identifierDeviceMetric.identifierElement `DeviceMetric.identifier` is mapped to FHIR STU3 element `DeviceMetric.identifier` as `SourceIsBroaderThanTarget`. For identifiers assigned to a device by the device or gateway software, the `system` element of the identifier should be set to any identifier of the device.
DeviceMetric.typetypeis equivalent toDeviceMetric.typeDeviceMetric.typeElement `DeviceMetric.type` is mapped to FHIR STU3 element `DeviceMetric.type` as `Equivalent`. DeviceMetric.type can be referred to either IEEE 11073-10101 or LOINC.
DeviceMetric.unitunitis equivalent toDeviceMetric.unitDeviceMetric.unitElement `DeviceMetric.unit` is mapped to FHIR STU3 element `DeviceMetric.unit` as `Equivalent`. DeviceMetric.unit can refer to either UCUM or preferable a RTMMS coding system.
DeviceMetric.devicedeviceis related toDeviceMetric.parentDeviceMetric.parentElement `DeviceMetric.device` is mapped to FHIR STU3 element `DeviceMetric.source` as `SourceIsBroaderThanTarget`. Element `DeviceMetric.device` is mapped to FHIR STU3 element `DeviceMetric.parent` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.device` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `DeviceMetric.device` with unmapped reference targets: Device. Note if this is not the top level device - also know as the source device, it may be referenced in the device.parent element.
is related toDeviceMetric.sourceDeviceMetric.sourceElement `DeviceMetric.device` is mapped to FHIR STU3 element `DeviceMetric.source` as `SourceIsBroaderThanTarget`. Element `DeviceMetric.device` is mapped to FHIR STU3 element `DeviceMetric.parent` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.device` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `DeviceMetric.device` with unmapped reference targets: Device. Note if this is not the top level device - also know as the source device, it may be referenced in the device.parent element.
DeviceMetric.operationalStatusoperationalStatusis equivalent toDeviceMetric.operationalStatusDeviceMetric.operationalStatusElement `DeviceMetric.operationalStatus` is mapped to FHIR STU3 element `DeviceMetric.operationalStatus` as `Equivalent`.
DeviceMetric.colorcoloris equivalent toDeviceMetric.colorDeviceMetric.colorElement `DeviceMetric.color` is mapped to FHIR STU3 element `DeviceMetric.color` as `Equivalent`.
DeviceMetric.categorycategoryis equivalent toDeviceMetric.categoryDeviceMetric.categoryElement `DeviceMetric.category` is mapped to FHIR STU3 element `DeviceMetric.category` as `Equivalent`.
DeviceMetric.calibrationcalibrationmaps to wider conceptDeviceMetric.calibrationDeviceMetric.calibrationElement `DeviceMetric.calibration` is mapped to FHIR STU3 element `DeviceMetric.calibration` as `Equivalent`.
DeviceMetric.calibration.typetypeis equivalent toDeviceMetric.calibration.typeDeviceMetric.calibration.typeElement `DeviceMetric.calibration.type` is mapped to FHIR STU3 element `DeviceMetric.calibration.type` as `Equivalent`.
DeviceMetric.calibration.statestateis equivalent toDeviceMetric.calibration.stateDeviceMetric.calibration.stateElement `DeviceMetric.calibration.state` is mapped to FHIR STU3 element `DeviceMetric.calibration.state` as `Equivalent`.
DeviceMetric.calibration.timetimeis equivalent toDeviceMetric.calibration.timeDeviceMetric.calibration.timeElement `DeviceMetric.calibration.time` is mapped to FHIR STU3 element `DeviceMetric.calibration.time` as `Equivalent`.

Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|5.0.0 to R5: Indicates how often the metric is taken or recorded (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.measurementFrequency (measurementFrequency)maps to wider conceptExtension (R5: Indicates how often the metric is taken or recorded (new))Element `DeviceMetric.measurementFrequency` has a context of DeviceMetric based on following the parent source element upwards and mapping to `DeviceMetric`. Element `DeviceMetric.measurementFrequency` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Source1

{
  "resourceType": "ConceptMap",
  "id": "R5-DeviceMetric-element-map-to-R3",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r5.r3"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r5.r3"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ConceptMap/R5-DeviceMetric-element-map-to-R3",
  "version": "0.1.0",
  "name": "R5DeviceMetricElementMapToR3",
  "title": "Cross-version mapping for FHIR R5 DeviceMetric to FHIR STU3 DeviceMetric",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T16:05:15.6062504-05:00",
  "contact": [
    {
      "name": "FHIR Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "This ConceptMap represents cross-version mappings for elements from a FHIR R5 DeviceMetric to FHIR STU3.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "sourceUri": "http://hl7.org/fhir/5.0",
  "targetUri": "http://hl7.org/fhir/3.0",
  "group": [
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "targetVersion": "3.0.2",
      "element": [
        {
          "code": "DeviceMetric.meta",
          "display": "meta",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.meta",
              "display": "DeviceMetric.meta",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.meta` is mapped to FHIR STU3 element `DeviceMetric.meta` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.implicitRules",
          "display": "implicitRules",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.implicitRules",
              "display": "DeviceMetric.implicitRules",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.implicitRules` is mapped to FHIR STU3 element `DeviceMetric.implicitRules` as `Equivalent`.\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of its narrative along with other profiles, value sets, etc."
            }
          ]
        },
        {
          "code": "DeviceMetric.language",
          "display": "language",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.language",
              "display": "DeviceMetric.language",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.language` is mapped to FHIR STU3 element `DeviceMetric.language` as `Equivalent`.\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
            }
          ]
        },
        {
          "code": "DeviceMetric.text",
          "display": "text",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.text",
              "display": "DeviceMetric.text",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.text` is mapped to FHIR STU3 element `DeviceMetric.text` as `Equivalent`.\nContained resources do not have a narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied).  This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
            }
          ]
        },
        {
          "code": "DeviceMetric.contained",
          "display": "contained",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.contained",
              "display": "DeviceMetric.contained",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.contained` is mapped to FHIR STU3 element `DeviceMetric.contained` as `SourceIsBroaderThanTarget`.\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags in their meta elements, but SHALL NOT have security labels."
            }
          ]
        },
        {
          "code": "DeviceMetric.identifier",
          "display": "identifier",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.identifier",
              "display": "DeviceMetric.identifier",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.identifier` is mapped to FHIR STU3 element `DeviceMetric.identifier` as `SourceIsBroaderThanTarget`.\nFor identifiers assigned to a device by the device or gateway software, the `system` element of the identifier should be set to any identifier of the device."
            }
          ]
        },
        {
          "code": "DeviceMetric.type",
          "display": "type",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.type",
              "display": "DeviceMetric.type",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.type` is mapped to FHIR STU3 element `DeviceMetric.type` as `Equivalent`.\nDeviceMetric.type can be referred to either IEEE 11073-10101 or LOINC."
            }
          ]
        },
        {
          "code": "DeviceMetric.unit",
          "display": "unit",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.unit",
              "display": "DeviceMetric.unit",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.unit` is mapped to FHIR STU3 element `DeviceMetric.unit` as `Equivalent`.\nDeviceMetric.unit can refer to either UCUM or preferable a RTMMS coding system."
            }
          ]
        },
        {
          "code": "DeviceMetric.device",
          "display": "device",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "DeviceMetric.parent",
              "display": "DeviceMetric.parent",
              "equivalence": "relatedto",
              "comment": "Element `DeviceMetric.device` is mapped to FHIR STU3 element `DeviceMetric.source` as `SourceIsBroaderThanTarget`.\nElement `DeviceMetric.device` is mapped to FHIR STU3 element `DeviceMetric.parent` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.device` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `DeviceMetric.device` with unmapped reference targets: Device.\nNote if this is not the top level device - also know as the source device, it may be referenced in the device.parent element."
            },
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "DeviceMetric.source",
              "display": "DeviceMetric.source",
              "equivalence": "relatedto",
              "comment": "Element `DeviceMetric.device` is mapped to FHIR STU3 element `DeviceMetric.source` as `SourceIsBroaderThanTarget`.\nElement `DeviceMetric.device` is mapped to FHIR STU3 element `DeviceMetric.parent` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.device` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R5 element `DeviceMetric.device` with unmapped reference targets: Device.\nNote if this is not the top level device - also know as the source device, it may be referenced in the device.parent element."
            }
          ]
        },
        {
          "code": "DeviceMetric.operationalStatus",
          "display": "operationalStatus",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.operationalStatus",
              "display": "DeviceMetric.operationalStatus",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.operationalStatus` is mapped to FHIR STU3 element `DeviceMetric.operationalStatus` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.color",
          "display": "color",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.color",
              "display": "DeviceMetric.color",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.color` is mapped to FHIR STU3 element `DeviceMetric.color` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.category",
          "display": "category",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.category",
              "display": "DeviceMetric.category",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.category` is mapped to FHIR STU3 element `DeviceMetric.category` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration",
          "display": "calibration",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "DeviceMetric.calibration",
              "display": "DeviceMetric.calibration",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.calibration` is mapped to FHIR STU3 element `DeviceMetric.calibration` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.type",
          "display": "type",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.calibration.type",
              "display": "DeviceMetric.calibration.type",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.type` is mapped to FHIR STU3 element `DeviceMetric.calibration.type` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.state",
          "display": "state",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.calibration.state",
              "display": "DeviceMetric.calibration.state",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.state` is mapped to FHIR STU3 element `DeviceMetric.calibration.state` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.time",
          "display": "time",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.calibration.time",
              "display": "DeviceMetric.calibration.time",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.time` is mapped to FHIR STU3 element `DeviceMetric.calibration.time` as `Equivalent`."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "5.0.0",
      "target": "http://hl7.org/fhir/5.0/StructureDefinition/extension-DeviceMetric.measurementFrequency",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.measurementFrequency",
          "display": "measurementFrequency",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.measurementFrequency` has a context of DeviceMetric based on following the parent source element upwards and mapping to `DeviceMetric`.\nElement `DeviceMetric.measurementFrequency` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    }
  ]
}