FHIR IG analytics
| Package | hl7.fhir.uv.xver-r4b.r5 |
| Resource Type | ValueSet |
| Id | ValueSet-R4B-device-nametype-for-R5.json |
| FHIR Version | R5 |
| Source | http://hl7.org/fhir/uv/xver-r4b.r5/0.1.0/ValueSet-R4B-device-nametype-for-R5.html |
| URL | http://hl7.org/fhir/uv/xver/ValueSet/R4B-device-nametype-for-R5 |
| Version | 0.1.0 |
| Status | active |
| Date | 2026-03-17T21:02:03.8104715+00:00 |
| Name | R4BDeviceNametypeForR5 |
| Title | Cross-version ValueSet R4B.DeviceNameType for use in FHIR R5 |
| Realm | uv |
| Authority | hl7 |
| Description | This cross-version ValueSet represents content from http://hl7.org/fhir/ValueSet/device-nametype|4.3.0 for use in FHIR R5 that is appropriate for use but unavailable in `http://hl7.org/fhir/ValueSet/device-nametype|5.0.0`. |
| Purpose | This value set is part of the cross-version definitions generated to enable use of the
value set `http://hl7.org/fhir/ValueSet/device-nametype|4.3.0` as defined in FHIR R4B
in FHIR R5.
The source value set is bound to the following FHIR R4B elements:
* `Device.deviceName.type`
* `DeviceDefinition.deviceName.type`
The following concepts are not included in this cross-version definition because they have valid representations:
* `http://hl7.org/fhir/device-nametype#patient-reported-name`
* `http://hl7.org/fhir/device-nametype#user-friendly-name`
Following are the generation technical comments:
One or more source concepts are either not mapped or broader than their targets, so the value set relationship is broadened.
The source value set has more active concepts (6) than the target (3), so the source is broader than the target. |
Resources that use this resource
Resources that this resource uses
Narrative
Note: links and images are rebased to the (stated) source
This value set expansion contains 4 concepts.
| System | Version | Code | Display | Definition |
http://hl7.org/fhir/device-nametype | 4.3.0 | manufacturer-name | Manufacturer name | Manufacturer name. |
http://hl7.org/fhir/device-nametype | 4.3.0 | model-name | Model name | Model name. |
http://hl7.org/fhir/device-nametype | 4.3.0 | other | other | other. |
http://hl7.org/fhir/device-nametype | 4.3.0 | udi-label-name | UDI Label name | UDI Label name. |
Source1
{
"resourceType": "ValueSet",
"id": "R4B-device-nametype-for-R5",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 2
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "oo"
},
{
"extension": [
{
"url": "packageId",
"valueId": "hl7.fhir.uv.xver-r4b.r5"
},
{
"url": "version",
"valueString": "0.1.0"
},
{
"url": "uri",
"valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4b.r5"
}
],
"url": "http://hl7.org/fhir/StructureDefinition/package-source"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "trial-use",
"_valueCode": {
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4b.r5"
}
]
}
}
],
"url": "http://hl7.org/fhir/uv/xver/ValueSet/R4B-device-nametype-for-R5",
"version": "0.1.0",
"name": "R4BDeviceNametypeForR5",
"title": "Cross-version ValueSet R4B.DeviceNameType for use in FHIR R5",
"status": "active",
"experimental": false,
"date": "2026-03-17T21:02:03.8104715+00:00",
"publisher": "Orders and Observations",
"contact": [
{
"name": "Orders and Observations",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/orders"
}
]
}
],
"description": "This cross-version ValueSet represents content from http://hl7.org/fhir/ValueSet/device-nametype|4.3.0 for use in FHIR R5 that is appropriate for use but unavailable in `http://hl7.org/fhir/ValueSet/device-nametype|5.0.0`.",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001",
"display": "World"
}
]
}
],
"purpose": "This value set is part of the cross-version definitions generated to enable use of the\r\nvalue set `http://hl7.org/fhir/ValueSet/device-nametype|4.3.0` as defined in FHIR R4B\r\nin FHIR R5.\r\n\r\nThe source value set is bound to the following FHIR R4B elements:\r\n* `Device.deviceName.type`\n* `DeviceDefinition.deviceName.type`\r\n\r\nThe following concepts are not included in this cross-version definition because they have valid representations:\n\n* `http://hl7.org/fhir/device-nametype#patient-reported-name`\n* `http://hl7.org/fhir/device-nametype#user-friendly-name`\r\n\r\nFollowing are the generation technical comments:\r\nOne or more source concepts are either not mapped or broader than their targets, so the value set relationship is broadened.\nThe source value set has more active concepts (6) than the target (3), so the source is broader than the target.",
"compose": {
"include": [
{
"system": "http://hl7.org/fhir/device-nametype",
"version": "4.3.0",
"concept": [
{
"code": "manufacturer-name",
"display": "Manufacturer name"
},
{
"code": "model-name",
"display": "Model name"
},
{
"code": "other",
"display": "other"
},
{
"code": "udi-label-name",
"display": "UDI Label name"
}
]
}
]
},
"expansion": {
"timestamp": "2026-03-17T21:02:03.8104715+00:00",
"contains": [
{
"system": "http://hl7.org/fhir/device-nametype",
"version": "4.3.0",
"code": "manufacturer-name",
"display": "Manufacturer name"
},
{
"system": "http://hl7.org/fhir/device-nametype",
"version": "4.3.0",
"code": "model-name",
"display": "Model name"
},
{
"system": "http://hl7.org/fhir/device-nametype",
"version": "4.3.0",
"code": "other",
"display": "other"
},
{
"system": "http://hl7.org/fhir/device-nametype",
"version": "4.3.0",
"code": "udi-label-name",
"display": "UDI Label name"
}
]
}
}