FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r4b.r3
Resource TypeConceptMap
IdConceptMap-R4B-ManufacturedItemDefinition-element-map-to-R3.json
FHIR VersionR3
Sourcehttp://hl7.org/fhir/uv/xver-r4b.r3/0.1.0/ConceptMap-R4B-ManufacturedItemDefinition-element-map-to-R3.html
URLhttp://hl7.org/fhir/uv/xver/ConceptMap/R4B-ManufacturedItemDefinition-element-map-to-R3
Version0.1.0
Statusactive
Date2026-03-17T16:04:26.9986743-05:00
NameR4BManufacturedItemDefinitionElementMapToR3
TitleCross-version mapping for FHIR R4B ManufacturedItemDefinition to FHIR STU3 Basic
Realmuv
Authorityhl7
DescriptionThis ConceptMap represents cross-version mappings for elements from a FHIR R4B ManufacturedItemDefinition to FHIR STU3.

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
hl7.fhir.uv.xver-r4b.r4#0.1.0extension-ManufacturedItemDefinition.ingredientR4B: The ingredients of this manufactured item. Only needed if these are not specified by incoming references from the Ingredient resource (new)
hl7.fhir.uv.xver-r4b.r4#0.1.0extension-ManufacturedItemDefinition.manufacturedDoseFormR4B: Dose form as manufactured (before any necessary transformation) (new)
hl7.fhir.uv.xver-r4b.r4#0.1.0extension-ManufacturedItemDefinition.manufacturerR4B: Manufacturer of the item (Note that this should be named "manufacturer" but it currently causes technical issues) (new)
hl7.fhir.uv.xver-r4b.r4#0.1.0extension-ManufacturedItemDefinition.propertyR4B: General characteristics of this item (new)
hl7.fhir.uv.xver-r4b.r4#0.1.0extension-ManufacturedItemDefinition.statusR4B: draft | active | retired | unknown (new)
hl7.fhir.uv.xver-r4b.r4#0.1.0extension-ManufacturedItemDefinition.unitOfPresentationR4B: The “real world” units in which the quantity of the item is described (new)

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap R4B-ManufacturedItemDefinition-element-map-to-R3

Mapping from http://hl7.org/fhir/4.3 to http://hl7.org/fhir/3.0


Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition|4.3.0 to http://hl7.org/fhir/StructureDefinition/Basic|3.0.2

Source CodeRelationshipTarget CodeComment
ManufacturedItemDefinition.meta (meta)is equivalent toBasic.metaElement matches Basic element path `Basic.meta` (`Resource.meta`), use that element instead. Element `ManufacturedItemDefinition.meta` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.meta` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).
ManufacturedItemDefinition.implicitRules (implicitRules)is equivalent toBasic.implicitRulesElement matches Basic element path `Basic.implicitRules` (`Resource.implicitRules`), use that element instead. Element `ManufacturedItemDefinition.implicitRules` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.implicitRules` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.
ManufacturedItemDefinition.language (language)is equivalent toBasic.languageElement matches Basic element path `Basic.language` (`Resource.language`), use that element instead. Element `ManufacturedItemDefinition.language` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.language` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).
ManufacturedItemDefinition.text (text)is equivalent toBasic.textElement matches Basic element path `Basic.text` (`DomainResource.text`), use that element instead. Element `ManufacturedItemDefinition.text` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.text` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.
ManufacturedItemDefinition.contained (contained)is equivalent toBasic.containedElement matches Basic element path `Basic.contained` (`DomainResource.contained`), use that element instead. Element `ManufacturedItemDefinition.contained` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.contained` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.
ManufacturedItemDefinition.identifier (identifier)is equivalent toBasic.identifierElement matches Basic element path `Basic.identifier` (`Basic.identifier`), use that element instead. Element `ManufacturedItemDefinition.identifier` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.identifier` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition|4.3.0 to R4B: draft | active | retired | unknown (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ManufacturedItemDefinition.status (status)maps to wider conceptExtension (R4B: draft | active | retired | unknown (new))Element `ManufacturedItemDefinition.status` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.status` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). Allows filtering of manufactured items that are appropriate for use versus not.

Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition|4.3.0 to R4B: Dose form as manufactured (before any necessary transformation) (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ManufacturedItemDefinition.manufacturedDoseForm (manufacturedDoseForm)maps to wider conceptExtension (R4B: Dose form as manufactured (before any necessary transformation) (new))Element `ManufacturedItemDefinition.manufacturedDoseForm` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.manufacturedDoseForm` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition|4.3.0 to R4B: The “real world” units in which the quantity of the item is described (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ManufacturedItemDefinition.unitOfPresentation (unitOfPresentation)maps to wider conceptExtension (R4B: The “real world” units in which the quantity of the item is described (new))Element `ManufacturedItemDefinition.unitOfPresentation` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.unitOfPresentation` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition|4.3.0 to R4B: Manufacturer of the item (Note that this should be named "manufacturer" but it currently causes technical issues) (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ManufacturedItemDefinition.manufacturer (manufacturer)maps to wider conceptExtension (R4B: Manufacturer of the item (Note that this should be named "manufacturer" but it currently causes technical issues) (new))Element `ManufacturedItemDefinition.manufacturer` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.manufacturer` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 6 Mapping from http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition|4.3.0 to R4B: The ingredients of this manufactured item. Only needed if these are not specified by incoming references from the Ingredient resource (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ManufacturedItemDefinition.ingredient (ingredient)maps to wider conceptExtension (R4B: The ingredients of this manufactured item. Only needed if these are not specified by incoming references from the Ingredient resource (new))Element `ManufacturedItemDefinition.ingredient` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.ingredient` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 7 Mapping from http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition|4.3.0 to R4B: General characteristics of this item (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ManufacturedItemDefinition.property (property)maps to wider conceptExtension (R4B: General characteristics of this item (new))Element `ManufacturedItemDefinition.property` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.property` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).
ManufacturedItemDefinition.property.type (type)maps to wider conceptExtension.extension:type (R4B: A code expressing the type of characteristic (new))Element `ManufacturedItemDefinition.property.type` is part of an existing definition because parent element `ManufacturedItemDefinition.property` requires a cross-version extension. Element `ManufacturedItemDefinition.property.type` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.property.type` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).
ManufacturedItemDefinition.property.value[x] (value[x])maps to wider conceptExtension.extension:value (R4B: A value for the characteristic (new))Element `ManufacturedItemDefinition.property.value[x]` is part of an existing definition because parent element `ManufacturedItemDefinition.property` requires a cross-version extension. Element `ManufacturedItemDefinition.property.value[x]` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped. Element `ManufacturedItemDefinition.property.value[x]` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Source1

{
  "resourceType": "ConceptMap",
  "id": "R4B-ManufacturedItemDefinition-element-map-to-R3",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4b.r3"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4b.r3"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ConceptMap/R4B-ManufacturedItemDefinition-element-map-to-R3",
  "version": "0.1.0",
  "name": "R4BManufacturedItemDefinitionElementMapToR3",
  "title": "Cross-version mapping for FHIR R4B ManufacturedItemDefinition to FHIR STU3 Basic",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T16:04:26.9986743-05:00",
  "contact": [
    {
      "name": "FHIR Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "This ConceptMap represents cross-version mappings for elements from a FHIR R4B ManufacturedItemDefinition to FHIR STU3.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "sourceUri": "http://hl7.org/fhir/4.3",
  "targetUri": "http://hl7.org/fhir/3.0",
  "group": [
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/StructureDefinition/Basic",
      "targetVersion": "3.0.2",
      "element": [
        {
          "code": "ManufacturedItemDefinition.meta",
          "display": "meta",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.meta",
              "display": "Basic.meta",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.meta` (`Resource.meta`), use that element instead.\nElement `ManufacturedItemDefinition.meta` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.meta` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        },
        {
          "code": "ManufacturedItemDefinition.implicitRules",
          "display": "implicitRules",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.implicitRules",
              "display": "Basic.implicitRules",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.implicitRules` (`Resource.implicitRules`), use that element instead.\nElement `ManufacturedItemDefinition.implicitRules` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.implicitRules` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc."
            }
          ]
        },
        {
          "code": "ManufacturedItemDefinition.language",
          "display": "language",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.language",
              "display": "Basic.language",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.language` (`Resource.language`), use that element instead.\nElement `ManufacturedItemDefinition.language` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.language` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
            }
          ]
        },
        {
          "code": "ManufacturedItemDefinition.text",
          "display": "text",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.text",
              "display": "Basic.text",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.text` (`DomainResource.text`), use that element instead.\nElement `ManufacturedItemDefinition.text` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.text` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied).  This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
            }
          ]
        },
        {
          "code": "ManufacturedItemDefinition.contained",
          "display": "contained",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.contained",
              "display": "Basic.contained",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.contained` (`DomainResource.contained`), use that element instead.\nElement `ManufacturedItemDefinition.contained` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.contained` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels."
            }
          ]
        },
        {
          "code": "ManufacturedItemDefinition.identifier",
          "display": "identifier",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.identifier",
              "display": "Basic.identifier",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.identifier` (`Basic.identifier`), use that element instead.\nElement `ManufacturedItemDefinition.identifier` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.identifier` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-ManufacturedItemDefinition.status",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ManufacturedItemDefinition.status",
          "display": "status",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ManufacturedItemDefinition.status` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.status` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nAllows filtering of manufactured items that are appropriate for use versus not."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-ManufacturedItemDefinition.manufacturedDoseForm",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ManufacturedItemDefinition.manufacturedDoseForm",
          "display": "manufacturedDoseForm",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ManufacturedItemDefinition.manufacturedDoseForm` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.manufacturedDoseForm` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-ManufacturedItemDefinition.unitOfPresentation",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ManufacturedItemDefinition.unitOfPresentation",
          "display": "unitOfPresentation",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ManufacturedItemDefinition.unitOfPresentation` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.unitOfPresentation` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-ManufacturedItemDefinition.manufacturer",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ManufacturedItemDefinition.manufacturer",
          "display": "manufacturer",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ManufacturedItemDefinition.manufacturer` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.manufacturer` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-ManufacturedItemDefinition.ingredient",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ManufacturedItemDefinition.ingredient",
          "display": "ingredient",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ManufacturedItemDefinition.ingredient` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.ingredient` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ManufacturedItemDefinition",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-ManufacturedItemDefinition.property",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ManufacturedItemDefinition.property",
          "display": "property",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ManufacturedItemDefinition.property` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.property` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        },
        {
          "code": "ManufacturedItemDefinition.property.type",
          "display": "type",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:type",
              "equivalence": "wider",
              "comment": "Element `ManufacturedItemDefinition.property.type` is part of an existing definition because parent element `ManufacturedItemDefinition.property` requires a cross-version extension.\nElement `ManufacturedItemDefinition.property.type` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.property.type` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        },
        {
          "code": "ManufacturedItemDefinition.property.value[x]",
          "display": "value[x]",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:value",
              "equivalence": "wider",
              "comment": "Element `ManufacturedItemDefinition.property.value[x]` is part of an existing definition because parent element `ManufacturedItemDefinition.property` requires a cross-version extension.\nElement `ManufacturedItemDefinition.property.value[x]` is not mapped to FHIR STU3, since FHIR R4B `ManufacturedItemDefinition` is not mapped.\nElement `ManufacturedItemDefinition.property.value[x]` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    }
  ]
}