FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r4b.r3
Resource TypeConceptMap
IdConceptMap-R4B-DeviceMetric-element-map-to-R3.json
FHIR VersionR3
Sourcehttp://hl7.org/fhir/uv/xver-r4b.r3/0.1.0/ConceptMap-R4B-DeviceMetric-element-map-to-R3.html
URLhttp://hl7.org/fhir/uv/xver/ConceptMap/R4B-DeviceMetric-element-map-to-R3
Version0.1.0
Statusactive
Date2026-03-17T16:04:29.9007786-05:00
NameR4BDeviceMetricElementMapToR3
TitleCross-version mapping for FHIR R4B DeviceMetric to FHIR STU3 DeviceMetric
Realmuv
Authorityhl7
DescriptionThis ConceptMap represents cross-version mappings for elements from a FHIR R4B DeviceMetric to FHIR STU3.

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
hl7.fhir.uv.xver-r4b.r3#0.1.0extension-DeviceMetric.identifierR4B: Instance identifier additional types
hl7.fhir.uv.xver-r4b.r5#0.1.0extension-DeviceMetric.measurementPeriodR4B: Describes the measurement repetition time (new)
hl7.fhir.uv.xver-r4b.r3#0.1.0extension-DeviceMetric.metaR4B: meta additional types
hl7.fhir.uv.xver-r4b.r3#0.1.0extension-DeviceMetric.textR4B: text additional types

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap R4B-DeviceMetric-element-map-to-R3

Mapping from http://hl7.org/fhir/4.3 to http://hl7.org/fhir/3.0


Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|4.3.0 to http://hl7.org/fhir/StructureDefinition/DeviceMetric|3.0.2

Source CodeRelationshipTarget CodeComment
DeviceMetric.meta (meta)maps to wider conceptDeviceMetric.metaElement `DeviceMetric.meta` is mapped to FHIR STU3 element `DeviceMetric.meta` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.meta` do not cover the following types: Meta. The mappings for `DeviceMetric.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, source, tag, versionId.
DeviceMetric.implicitRules (implicitRules)is equivalent toDeviceMetric.implicitRulesElement `DeviceMetric.implicitRules` is mapped to FHIR STU3 element `DeviceMetric.implicitRules` as `Equivalent`. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.
DeviceMetric.language (language)is equivalent toDeviceMetric.languageElement `DeviceMetric.language` is mapped to FHIR STU3 element `DeviceMetric.language` as `Equivalent`. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).
DeviceMetric.text (text)maps to wider conceptDeviceMetric.textElement `DeviceMetric.text` is mapped to FHIR STU3 element `DeviceMetric.text` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.text` do not cover the following types: Narrative. The mappings for `DeviceMetric.text` do not cover the following types based on type expansion: div, status. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.
DeviceMetric.contained (contained)is equivalent toDeviceMetric.containedElement `DeviceMetric.contained` is mapped to FHIR STU3 element `DeviceMetric.contained` as `SourceIsBroaderThanTarget`. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.
DeviceMetric.identifier (identifier)maps to wider conceptDeviceMetric.identifierElement `DeviceMetric.identifier` is mapped to FHIR STU3 element `DeviceMetric.identifier` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.identifier` do not cover the following types: Identifier. The mappings for `DeviceMetric.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value. For identifiers assigned to a device by the device or gateway software, the `system` element of the identifier should be set to the unique identifier of the device.
DeviceMetric.type (type)is equivalent toDeviceMetric.typeElement `DeviceMetric.type` is mapped to FHIR STU3 element `DeviceMetric.type` as `Equivalent`. DeviceMetric.type can be referred to either IEEE 11073-10101 or LOINC.
DeviceMetric.unit (unit)is equivalent toDeviceMetric.unitElement `DeviceMetric.unit` is mapped to FHIR STU3 element `DeviceMetric.unit` as `Equivalent`. DeviceMetric.unit can refer to either UCUM or preferable a RTMMS coding system.
DeviceMetric.source (source)maps to wider conceptDeviceMetric.sourceElement `DeviceMetric.source` is mapped to FHIR STU3 element `DeviceMetric.source` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.source` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `DeviceMetric.source` with unmapped reference targets: Device.
DeviceMetric.parent (parent)maps to wider conceptDeviceMetric.parentElement `DeviceMetric.parent` is mapped to FHIR STU3 element `DeviceMetric.parent` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.parent` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `DeviceMetric.parent` with unmapped reference targets: Device.
DeviceMetric.operationalStatus (operationalStatus)is equivalent toDeviceMetric.operationalStatusElement `DeviceMetric.operationalStatus` is mapped to FHIR STU3 element `DeviceMetric.operationalStatus` as `Equivalent`.
DeviceMetric.color (color)is equivalent toDeviceMetric.colorElement `DeviceMetric.color` is mapped to FHIR STU3 element `DeviceMetric.color` as `Equivalent`.
DeviceMetric.category (category)is equivalent toDeviceMetric.categoryElement `DeviceMetric.category` is mapped to FHIR STU3 element `DeviceMetric.category` as `Equivalent`.
DeviceMetric.measurementPeriod (measurementPeriod)maps to wider conceptDeviceMetric.measurementPeriodElement `DeviceMetric.measurementPeriod` is mapped to FHIR STU3 element `DeviceMetric.measurementPeriod` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.measurementPeriod` do not cover the following types: Timing. The mappings for `DeviceMetric.measurementPeriod` do not cover the following types based on type expansion: bounds[x], code, count, countMax, dayOfWeek, duration, durationMax, durationUnit, event, frequency, frequencyMax, offset, period, periodMax, periodUnit, repeat, timeOfDay, when.
DeviceMetric.calibration (calibration)maps to wider conceptDeviceMetric.calibrationElement `DeviceMetric.calibration` is mapped to FHIR STU3 element `DeviceMetric.calibration` as `Equivalent`.
DeviceMetric.calibration.type (type)is equivalent toDeviceMetric.calibration.typeElement `DeviceMetric.calibration.type` is mapped to FHIR STU3 element `DeviceMetric.calibration.type` as `Equivalent`.
DeviceMetric.calibration.state (state)is equivalent toDeviceMetric.calibration.stateElement `DeviceMetric.calibration.state` is mapped to FHIR STU3 element `DeviceMetric.calibration.state` as `Equivalent`.
DeviceMetric.calibration.time (time)is equivalent toDeviceMetric.calibration.timeElement `DeviceMetric.calibration.time` is mapped to FHIR STU3 element `DeviceMetric.calibration.time` as `Equivalent`.

Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|4.3.0 to R4B: meta additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.meta (meta)is equivalent toExtension (R4B: meta additional types)Element `DeviceMetric.meta` is mapped to FHIR STU3 element `DeviceMetric.meta` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.meta` do not cover the following types: Meta. The mappings for `DeviceMetric.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, source, tag, versionId.

Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|4.3.0 to R4B: text additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.text (text)is equivalent toExtension (R4B: text additional types)Element `DeviceMetric.text` is mapped to FHIR STU3 element `DeviceMetric.text` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.text` do not cover the following types: Narrative. The mappings for `DeviceMetric.text` do not cover the following types based on type expansion: div, status. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.

Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|4.3.0 to R4B: Instance identifier additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.identifier (identifier)is equivalent toExtension (R4B: Instance identifier additional types)Element `DeviceMetric.identifier` is mapped to FHIR STU3 element `DeviceMetric.identifier` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.identifier` do not cover the following types: Identifier. The mappings for `DeviceMetric.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value. For identifiers assigned to a device by the device or gateway software, the `system` element of the identifier should be set to the unique identifier of the device.

Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|4.3.0 to R4B: measurementPeriod additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.measurementPeriod (measurementPeriod)is equivalent toExtension (R4B: measurementPeriod additional types)Element `DeviceMetric.measurementPeriod` is mapped to FHIR STU3 element `DeviceMetric.measurementPeriod` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.measurementPeriod` do not cover the following types: Timing. The mappings for `DeviceMetric.measurementPeriod` do not cover the following types based on type expansion: bounds[x], code, count, countMax, dayOfWeek, duration, durationMax, durationUnit, event, frequency, frequencyMax, offset, period, periodMax, periodUnit, repeat, timeOfDay, when.

Source1

{
  "resourceType": "ConceptMap",
  "id": "R4B-DeviceMetric-element-map-to-R3",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4b.r3"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4b.r3"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ConceptMap/R4B-DeviceMetric-element-map-to-R3",
  "version": "0.1.0",
  "name": "R4BDeviceMetricElementMapToR3",
  "title": "Cross-version mapping for FHIR R4B DeviceMetric to FHIR STU3 DeviceMetric",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T16:04:29.9007786-05:00",
  "contact": [
    {
      "name": "FHIR Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "This ConceptMap represents cross-version mappings for elements from a FHIR R4B DeviceMetric to FHIR STU3.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "sourceUri": "http://hl7.org/fhir/4.3",
  "targetUri": "http://hl7.org/fhir/3.0",
  "group": [
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "targetVersion": "3.0.2",
      "element": [
        {
          "code": "DeviceMetric.meta",
          "display": "meta",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "DeviceMetric.meta",
              "display": "DeviceMetric.meta",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.meta` is mapped to FHIR STU3 element `DeviceMetric.meta` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.meta` do not cover the following types: Meta.\nThe mappings for `DeviceMetric.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, source, tag, versionId."
            }
          ]
        },
        {
          "code": "DeviceMetric.implicitRules",
          "display": "implicitRules",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.implicitRules",
              "display": "DeviceMetric.implicitRules",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.implicitRules` is mapped to FHIR STU3 element `DeviceMetric.implicitRules` as `Equivalent`.\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc."
            }
          ]
        },
        {
          "code": "DeviceMetric.language",
          "display": "language",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.language",
              "display": "DeviceMetric.language",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.language` is mapped to FHIR STU3 element `DeviceMetric.language` as `Equivalent`.\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
            }
          ]
        },
        {
          "code": "DeviceMetric.text",
          "display": "text",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "DeviceMetric.text",
              "display": "DeviceMetric.text",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.text` is mapped to FHIR STU3 element `DeviceMetric.text` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.text` do not cover the following types: Narrative.\nThe mappings for `DeviceMetric.text` do not cover the following types based on type expansion: div, status.\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied).  This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
            }
          ]
        },
        {
          "code": "DeviceMetric.contained",
          "display": "contained",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.contained",
              "display": "DeviceMetric.contained",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.contained` is mapped to FHIR STU3 element `DeviceMetric.contained` as `SourceIsBroaderThanTarget`.\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels."
            }
          ]
        },
        {
          "code": "DeviceMetric.identifier",
          "display": "identifier",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "DeviceMetric.identifier",
              "display": "DeviceMetric.identifier",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.identifier` is mapped to FHIR STU3 element `DeviceMetric.identifier` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.identifier` do not cover the following types: Identifier.\nThe mappings for `DeviceMetric.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value.\nFor identifiers assigned to a device by the device or gateway software, the `system` element of the identifier should be set to the unique identifier of the device."
            }
          ]
        },
        {
          "code": "DeviceMetric.type",
          "display": "type",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.type",
              "display": "DeviceMetric.type",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.type` is mapped to FHIR STU3 element `DeviceMetric.type` as `Equivalent`.\nDeviceMetric.type can be referred to either IEEE 11073-10101 or LOINC."
            }
          ]
        },
        {
          "code": "DeviceMetric.unit",
          "display": "unit",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.unit",
              "display": "DeviceMetric.unit",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.unit` is mapped to FHIR STU3 element `DeviceMetric.unit` as `Equivalent`.\nDeviceMetric.unit can refer to either UCUM or preferable a RTMMS coding system."
            }
          ]
        },
        {
          "code": "DeviceMetric.source",
          "display": "source",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "DeviceMetric.source",
              "display": "DeviceMetric.source",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.source` is mapped to FHIR STU3 element `DeviceMetric.source` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.source` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `DeviceMetric.source` with unmapped reference targets: Device."
            }
          ]
        },
        {
          "code": "DeviceMetric.parent",
          "display": "parent",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "DeviceMetric.parent",
              "display": "DeviceMetric.parent",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.parent` is mapped to FHIR STU3 element `DeviceMetric.parent` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.parent` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `DeviceMetric.parent` with unmapped reference targets: Device."
            }
          ]
        },
        {
          "code": "DeviceMetric.operationalStatus",
          "display": "operationalStatus",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.operationalStatus",
              "display": "DeviceMetric.operationalStatus",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.operationalStatus` is mapped to FHIR STU3 element `DeviceMetric.operationalStatus` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.color",
          "display": "color",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.color",
              "display": "DeviceMetric.color",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.color` is mapped to FHIR STU3 element `DeviceMetric.color` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.category",
          "display": "category",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.category",
              "display": "DeviceMetric.category",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.category` is mapped to FHIR STU3 element `DeviceMetric.category` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.measurementPeriod",
          "display": "measurementPeriod",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "DeviceMetric.measurementPeriod",
              "display": "DeviceMetric.measurementPeriod",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.measurementPeriod` is mapped to FHIR STU3 element `DeviceMetric.measurementPeriod` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.measurementPeriod` do not cover the following types: Timing.\nThe mappings for `DeviceMetric.measurementPeriod` do not cover the following types based on type expansion: bounds[x], code, count, countMax, dayOfWeek, duration, durationMax, durationUnit, event, frequency, frequencyMax, offset, period, periodMax, periodUnit, repeat, timeOfDay, when."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration",
          "display": "calibration",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "DeviceMetric.calibration",
              "display": "DeviceMetric.calibration",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.calibration` is mapped to FHIR STU3 element `DeviceMetric.calibration` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.type",
          "display": "type",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.calibration.type",
              "display": "DeviceMetric.calibration.type",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.type` is mapped to FHIR STU3 element `DeviceMetric.calibration.type` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.state",
          "display": "state",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.calibration.state",
              "display": "DeviceMetric.calibration.state",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.state` is mapped to FHIR STU3 element `DeviceMetric.calibration.state` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.time",
          "display": "time",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "DeviceMetric.calibration.time",
              "display": "DeviceMetric.calibration.time",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.time` is mapped to FHIR STU3 element `DeviceMetric.calibration.time` as `Equivalent`."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-DeviceMetric.meta",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.meta",
          "display": "meta",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.meta` is mapped to FHIR STU3 element `DeviceMetric.meta` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.meta` do not cover the following types: Meta.\nThe mappings for `DeviceMetric.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, source, tag, versionId."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-DeviceMetric.text",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.text",
          "display": "text",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.text` is mapped to FHIR STU3 element `DeviceMetric.text` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.text` do not cover the following types: Narrative.\nThe mappings for `DeviceMetric.text` do not cover the following types based on type expansion: div, status.\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied).  This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-DeviceMetric.identifier",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.identifier",
          "display": "identifier",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.identifier` is mapped to FHIR STU3 element `DeviceMetric.identifier` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.identifier` do not cover the following types: Identifier.\nThe mappings for `DeviceMetric.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value.\nFor identifiers assigned to a device by the device or gateway software, the `system` element of the identifier should be set to the unique identifier of the device."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "4.3.0",
      "target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-DeviceMetric.measurementPeriod",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.measurementPeriod",
          "display": "measurementPeriod",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.measurementPeriod` is mapped to FHIR STU3 element `DeviceMetric.measurementPeriod` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.measurementPeriod` do not cover the following types: Timing.\nThe mappings for `DeviceMetric.measurementPeriod` do not cover the following types based on type expansion: bounds[x], code, count, countMax, dayOfWeek, duration, durationMax, durationUnit, event, frequency, frequencyMax, offset, period, periodMax, periodUnit, repeat, timeOfDay, when."
            }
          ]
        }
      ]
    }
  ]
}