FHIR IG analytics| Package | hl7.fhir.uv.xver-r4b.r3 |
| Resource Type | ConceptMap |
| Id | ConceptMap-R4B-Device-element-map-to-R3.json |
| FHIR Version | R3 |
| Source | http://hl7.org/fhir/uv/xver-r4b.r3/0.1.0/ConceptMap-R4B-Device-element-map-to-R3.html |
| URL | http://hl7.org/fhir/uv/xver/ConceptMap/R4B-Device-element-map-to-R3 |
| Version | 0.1.0 |
| Status | active |
| Date | 2026-03-17T16:04:29.2862073-05:00 |
| Name | R4BDeviceElementMapToR3 |
| Title | Cross-version mapping for FHIR R4B Device to FHIR STU3 Device |
| Realm | uv |
| Authority | hl7 |
| Description | This ConceptMap represents cross-version mappings for elements from a FHIR R4B Device to FHIR STU3. |
No resources found
| StructureDefinition | ||
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.contact | R4B: contact additional types |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.definition | R4B: The reference to the definition for the device (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.deviceName.name | R4B: The name that identifies the device (new) |
| hl7.fhir.uv.xver-r4b.r5#0.1.0 | extension-Device.deviceName.type | R4B: udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other |
| hl7.fhir.uv.xver-r4b.r5#0.1.0 | extension-Device.distinctIdentifier | R4B: The distinct identification string (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.identifier | R4B: identifier additional types |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.meta | R4B: meta additional types |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.note | R4B: note additional types |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.parent | R4B: The device that this device is attached to or is part of (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.partNumber | R4B: The part number or catalog number of the device (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.property | R4B: The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.serialNumber | R4B: Serial number assigned by the manufacturer (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.specialization | R4B: The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.statusReason | R4B: online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.text | R4B: text additional types |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.version.component | R4B: A single component of the device version (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.version.type | R4B: The type of the device version, e.g. manufacturer, approved, internal (new) |
| hl7.fhir.uv.xver-r4b.r3#0.1.0 | extension-Device.version.value | R4B: The version text (new) |
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap R4B-Device-element-map-to-R3
Mapping from http://hl7.org/fhir/4.3 to http://hl7.org/fhir/3.0
Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to http://hl7.org/fhir/StructureDefinition/Device|3.0.2
| Source Code | Relationship | Target Code | Comment |
| Device.meta (meta) | maps to wider concept | Device.meta | Element `Device.meta` is mapped to FHIR STU3 element `Device.meta` as `SourceIsBroaderThanTarget`. The mappings for `Device.meta` do not cover the following types: Meta. The mappings for `Device.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, source, tag, versionId. |
| Device.implicitRules (implicitRules) | is equivalent to | Device.implicitRules | Element `Device.implicitRules` is mapped to FHIR STU3 element `Device.implicitRules` as `Equivalent`. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. |
| Device.language (language) | is equivalent to | Device.language | Element `Device.language` is mapped to FHIR STU3 element `Device.language` as `Equivalent`. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). |
| Device.text (text) | maps to wider concept | Device.text | Element `Device.text` is mapped to FHIR STU3 element `Device.text` as `SourceIsBroaderThanTarget`. The mappings for `Device.text` do not cover the following types: Narrative. The mappings for `Device.text` do not cover the following types based on type expansion: div, status. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. |
| Device.contained (contained) | is equivalent to | Device.contained | Element `Device.contained` is mapped to FHIR STU3 element `Device.contained` as `SourceIsBroaderThanTarget`. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels. |
| Device.identifier (identifier) | maps to wider concept | Device.identifier | Element `Device.identifier` is mapped to FHIR STU3 element `Device.identifier` as `SourceIsBroaderThanTarget`. The mappings for `Device.identifier` do not cover the following types: Identifier. The mappings for `Device.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used. |
| Device.udiCarrier (udiCarrier) | maps to wider concept | Device.udi | Element `Device.udiCarrier` is mapped to FHIR STU3 element `Device.udi` as `SourceIsBroaderThanTarget`. UDI may identify an unique instance of a device, or it may only identify the type of the device. See [UDI mappings](https://hl7.org/fhir/devi.html#udi) for a complete mapping of UDI parts to Device. |
| Device.udiCarrier.deviceIdentifier (deviceIdentifier) | is equivalent to | Device.udi.deviceIdentifier | Element `Device.udiCarrier.deviceIdentifier` is mapped to FHIR STU3 element `Device.udi.deviceIdentifier` as `Equivalent`. |
| Device.udiCarrier.issuer (issuer) | is equivalent to | Device.udi.issuer | Element `Device.udiCarrier.issuer` is mapped to FHIR STU3 element `Device.udi.issuer` as `Equivalent`. |
| Device.udiCarrier.jurisdiction (jurisdiction) | is equivalent to | Device.udi.jurisdiction | Element `Device.udiCarrier.jurisdiction` is mapped to FHIR STU3 element `Device.udi.jurisdiction` as `Equivalent`. |
| Device.udiCarrier.carrierAIDC (carrierAIDC) | is equivalent to | Device.udi.carrierAIDC | Element `Device.udiCarrier.carrierAIDC` is mapped to FHIR STU3 element `Device.udi.carrierAIDC` as `Equivalent`. The AIDC form of UDIs should be scanned or otherwise used for the identification of the device whenever possible to minimize errors in records resulting from manual transcriptions. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label. |
| Device.udiCarrier.carrierHRF (carrierHRF) | is equivalent to | Device.udi.carrierHRF | Element `Device.udiCarrier.carrierHRF` is mapped to FHIR STU3 element `Device.udi.carrierHRF` as `Equivalent`. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label. |
| Device.udiCarrier.entryType (entryType) | is equivalent to | Device.udi.entryType | Element `Device.udiCarrier.entryType` is mapped to FHIR STU3 element `Device.udi.entryType` as `Equivalent`. |
| Device.status (status) | is equivalent to | Device.status | Element `Device.status` is mapped to FHIR STU3 element `Device.status` as `Equivalent`. This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid. |
| Device.manufacturer (manufacturer) | is equivalent to | Device.manufacturer | Element `Device.manufacturer` is mapped to FHIR STU3 element `Device.manufacturer` as `Equivalent`. |
| Device.manufactureDate (manufactureDate) | is equivalent to | Device.manufactureDate | Element `Device.manufactureDate` is mapped to FHIR STU3 element `Device.manufactureDate` as `Equivalent`. |
| Device.expirationDate (expirationDate) | is equivalent to | Device.expirationDate | Element `Device.expirationDate` is mapped to FHIR STU3 element `Device.expirationDate` as `Equivalent`. |
| Device.lotNumber (lotNumber) | is equivalent to | Device.lotNumber | Element `Device.lotNumber` is mapped to FHIR STU3 element `Device.lotNumber` as `Equivalent`. |
| Device.deviceName (deviceName) | maps to wider concept | Device.udi | Element `Device.deviceName` is mapped to FHIR STU3 element `Device.udi` as `SourceIsBroaderThanTarget`. |
| Device.modelNumber (modelNumber) | is equivalent to | Device.model | Element `Device.modelNumber` is mapped to FHIR STU3 element `Device.model` as `Equivalent`. |
| Device.type (type) | is equivalent to | Device.type | Element `Device.type` is mapped to FHIR STU3 element `Device.type` as `Equivalent`. |
| Device.version (version) | maps to wider concept | Device.version | Element `Device.version` is mapped to FHIR STU3 element `Device.version` as `SourceIsBroaderThanTarget`. |
| Device.patient (patient) | maps to wider concept | Device.patient | Element `Device.patient` is mapped to FHIR STU3 element `Device.patient` as `SourceIsBroaderThanTarget`. The mappings for `Device.patient` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `Device.patient` with unmapped reference targets: Patient. |
| Device.owner (owner) | maps to wider concept | Device.owner | Element `Device.owner` is mapped to FHIR STU3 element `Device.owner` as `SourceIsBroaderThanTarget`. The mappings for `Device.owner` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `Device.owner` with unmapped reference targets: Organization. |
| Device.contact (contact) | maps to wider concept | Device.contact | Element `Device.contact` is mapped to FHIR STU3 element `Device.contact` as `SourceIsBroaderThanTarget`. The mappings for `Device.contact` do not cover the following types: ContactPoint. The mappings for `Device.contact` do not cover the following types based on type expansion: period, rank, system, use, value. used for troubleshooting etc. |
| Device.location (location) | maps to wider concept | Device.location | Element `Device.location` is mapped to FHIR STU3 element `Device.location` as `SourceIsBroaderThanTarget`. The mappings for `Device.location` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `Device.location` with unmapped reference targets: Location. |
| Device.url (url) | is equivalent to | Device.url | Element `Device.url` is mapped to FHIR STU3 element `Device.url` as `Equivalent`. If the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved. |
| Device.note (note) | maps to wider concept | Device.note | Element `Device.note` is mapped to FHIR STU3 element `Device.note` as `SourceIsBroaderThanTarget`. The mappings for `Device.note` do not cover the following types: Annotation. The mappings for `Device.note` do not cover the following types based on type expansion: author[x], text, time. |
| Device.safety (safety) | is equivalent to | Device.safety | Element `Device.safety` is mapped to FHIR STU3 element `Device.safety` as `Equivalent`. |
Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: meta additional typesversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.meta (meta) | is equivalent to | Extension (R4B: meta additional types) | Element `Device.meta` is mapped to FHIR STU3 element `Device.meta` as `SourceIsBroaderThanTarget`. The mappings for `Device.meta` do not cover the following types: Meta. The mappings for `Device.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, source, tag, versionId. |
Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: text additional typesversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.text (text) | is equivalent to | Extension (R4B: text additional types) | Element `Device.text` is mapped to FHIR STU3 element `Device.text` as `SourceIsBroaderThanTarget`. The mappings for `Device.text` do not cover the following types: Narrative. The mappings for `Device.text` do not cover the following types based on type expansion: div, status. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. |
Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: identifier additional typesversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.identifier (identifier) | is equivalent to | Extension (R4B: identifier additional types) | Element `Device.identifier` is mapped to FHIR STU3 element `Device.identifier` as `SourceIsBroaderThanTarget`. The mappings for `Device.identifier` do not cover the following types: Identifier. The mappings for `Device.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used. |
Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The reference to the definition for the device (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.definition (definition) | is equivalent to | Extension (R4B: The reference to the definition for the device (new)) | Element `Device.definition` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.definition` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 6 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.statusReason (statusReason) | is equivalent to | Extension (R4B: online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off (new)) | Element `Device.statusReason` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.statusReason` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 7 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The distinct identification string (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.distinctIdentifier (distinctIdentifier) | is equivalent to | Extension (R4B: The distinct identification string (new)) | Element `Device.distinctIdentifier` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.distinctIdentifier` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). For example, this applies to devices in the United States regulated under *Code of Federal Regulation 21CFR§1271.290(c)*. |
Group 8 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: Serial number assigned by the manufacturer (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.serialNumber (serialNumber) | is equivalent to | Extension (R4B: Serial number assigned by the manufacturer (new)) | Element `Device.serialNumber` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.serialNumber` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). Alphanumeric Maximum 20. |
Group 9 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The name that identifies the device (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.deviceName.name (name) | is equivalent to | Extension (R4B: The name that identifies the device (new)) | Element `Device.deviceName.name` has a context of Device.udi based on following the parent source element upwards and mapping to `Device`. Element `Device.deviceName.name` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 10 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.deviceName.type (type) | is equivalent to | Extension (R4B: udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other (new)) | Element `Device.deviceName.type` has a context of Device.udi based on following the parent source element upwards and mapping to `Device`. Element `Device.deviceName.type` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 11 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The part number or catalog number of the device (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.partNumber (partNumber) | is equivalent to | Extension (R4B: The part number or catalog number of the device (new)) | Element `Device.partNumber` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.partNumber` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). Alphanumeric Maximum 20. |
Group 12 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.specialization (specialization) | is equivalent to | Extension (R4B: The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication (new)) | Element `Device.specialization` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.specialization` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
| Device.specialization.systemType (systemType) | is equivalent to | Extension.extension:systemType (R4B: The standard that is used to operate and communicate (new)) | Element `Device.specialization.systemType` is part of an existing definition because parent element `Device.specialization` requires a cross-version extension. Element `Device.specialization.systemType` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.specialization.systemType` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
| Device.specialization.version (version) | is equivalent to | Extension.extension:version (R4B: The version of the standard that is used to operate and communicate (new)) | Element `Device.specialization.version` is part of an existing definition because parent element `Device.specialization` requires a cross-version extension. Element `Device.specialization.version` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.specialization.version` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 13 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The type of the device version, e.g. manufacturer, approved, internal (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.version.type (type) | is equivalent to | Extension (R4B: The type of the device version, e.g. manufacturer, approved, internal (new)) | Element `Device.version.type` has a context of Device.version based on following the parent source element upwards and mapping to `Device`. Element `Device.version.type` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 14 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: A single component of the device version (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.version.component (component) | is equivalent to | Extension (R4B: A single component of the device version (new)) | Element `Device.version.component` has a context of Device.version based on following the parent source element upwards and mapping to `Device`. Element `Device.version.component` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 15 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The version text (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.version.value (value) | is equivalent to | Extension (R4B: The version text (new)) | Element `Device.version.value` has a context of Device.version based on following the parent source element upwards and mapping to `Device`. Element `Device.version.value` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 16 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.property (property) | is equivalent to | Extension (R4B: The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties (new)) | Element `Device.property` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.property` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
| Device.property.type (type) | is equivalent to | Extension.extension:type (R4B: Code that specifies the property DeviceDefinitionPropetyCode (Extensible) (new)) | Element `Device.property.type` is part of an existing definition because parent element `Device.property` requires a cross-version extension. Element `Device.property.type` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.property.type` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
| Device.property.valueQuantity (valueQuantity) | is equivalent to | Extension.extension:valueQuantity (R4B: Property value as a quantity (new)) | Element `Device.property.valueQuantity` is part of an existing definition because parent element `Device.property` requires a cross-version extension. Element `Device.property.valueQuantity` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.property.valueQuantity` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
| Device.property.valueCode (valueCode) | is equivalent to | Extension.extension:valueCode (R4B: Property value as a code, e.g., NTP4 (synced to NTP) (new)) | Element `Device.property.valueCode` is part of an existing definition because parent element `Device.property` requires a cross-version extension. Element `Device.property.valueCode` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.property.valueCode` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
Group 17 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: contact additional typesversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.contact (contact) | is equivalent to | Extension (R4B: contact additional types) | Element `Device.contact` is mapped to FHIR STU3 element `Device.contact` as `SourceIsBroaderThanTarget`. The mappings for `Device.contact` do not cover the following types: ContactPoint. The mappings for `Device.contact` do not cover the following types based on type expansion: period, rank, system, use, value. used for troubleshooting etc. |
Group 18 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: note additional typesversion: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.note (note) | is equivalent to | Extension (R4B: note additional types) | Element `Device.note` is mapped to FHIR STU3 element `Device.note` as `SourceIsBroaderThanTarget`. The mappings for `Device.note` do not cover the following types: Annotation. The mappings for `Device.note` do not cover the following types based on type expansion: author[x], text, time. |
Group 19 Mapping from http://hl7.org/fhir/StructureDefinition/Device|4.3.0 to R4B: The device that this device is attached to or is part of (new)version: 0.1.0)
| Source Code | Relationship | Target Code | Comment |
| Device.parent (parent) | is equivalent to | Extension (R4B: The device that this device is attached to or is part of (new)) | Element `Device.parent` has a context of Device based on following the parent source element upwards and mapping to `Device`. Element `Device.parent` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element). |
{
"resourceType": "ConceptMap",
"id": "R4B-Device-element-map-to-R3",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "fhir"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 0,
"_valueInteger": {
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4b.r3"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "trial-use",
"_valueCode": {
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4b.r3"
}
]
}
}
],
"url": "http://hl7.org/fhir/uv/xver/ConceptMap/R4B-Device-element-map-to-R3",
"version": "0.1.0",
"name": "R4BDeviceElementMapToR3",
"title": "Cross-version mapping for FHIR R4B Device to FHIR STU3 Device",
"status": "active",
"experimental": false,
"date": "2026-03-17T16:04:29.2862073-05:00",
"contact": [
{
"name": "FHIR Infrastructure",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/fiwg"
}
]
}
],
"description": "This ConceptMap represents cross-version mappings for elements from a FHIR R4B Device to FHIR STU3.",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001",
"display": "World"
}
]
}
],
"sourceUri": "http://hl7.org/fhir/4.3",
"targetUri": "http://hl7.org/fhir/3.0",
"group": [
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/StructureDefinition/Device",
"targetVersion": "3.0.2",
"element": [
{
"code": "Device.meta",
"display": "meta",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.meta",
"display": "Device.meta",
"equivalence": "wider",
"comment": "Element `Device.meta` is mapped to FHIR STU3 element `Device.meta` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.meta` do not cover the following types: Meta.\nThe mappings for `Device.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, source, tag, versionId."
}
]
},
{
"code": "Device.implicitRules",
"display": "implicitRules",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.implicitRules",
"display": "Device.implicitRules",
"equivalence": "equivalent",
"comment": "Element `Device.implicitRules` is mapped to FHIR STU3 element `Device.implicitRules` as `Equivalent`.\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc."
}
]
},
{
"code": "Device.language",
"display": "language",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.language",
"display": "Device.language",
"equivalence": "equivalent",
"comment": "Element `Device.language` is mapped to FHIR STU3 element `Device.language` as `Equivalent`.\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
}
]
},
{
"code": "Device.text",
"display": "text",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.text",
"display": "Device.text",
"equivalence": "wider",
"comment": "Element `Device.text` is mapped to FHIR STU3 element `Device.text` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.text` do not cover the following types: Narrative.\nThe mappings for `Device.text` do not cover the following types based on type expansion: div, status.\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
}
]
},
{
"code": "Device.contained",
"display": "contained",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.contained",
"display": "Device.contained",
"equivalence": "equivalent",
"comment": "Element `Device.contained` is mapped to FHIR STU3 element `Device.contained` as `SourceIsBroaderThanTarget`.\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels."
}
]
},
{
"code": "Device.identifier",
"display": "identifier",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.identifier",
"display": "Device.identifier",
"equivalence": "wider",
"comment": "Element `Device.identifier` is mapped to FHIR STU3 element `Device.identifier` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.identifier` do not cover the following types: Identifier.\nThe mappings for `Device.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value.\nThe barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used."
}
]
},
{
"code": "Device.udiCarrier",
"display": "udiCarrier",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.udi",
"display": "Device.udi",
"equivalence": "wider",
"comment": "Element `Device.udiCarrier` is mapped to FHIR STU3 element `Device.udi` as `SourceIsBroaderThanTarget`.\nUDI may identify an unique instance of a device, or it may only identify the type of the device. See [UDI mappings](https://hl7.org/fhir/devi.html#udi) for a complete mapping of UDI parts to Device."
}
]
},
{
"code": "Device.udiCarrier.deviceIdentifier",
"display": "deviceIdentifier",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.udi.deviceIdentifier",
"display": "Device.udi.deviceIdentifier",
"equivalence": "equivalent",
"comment": "Element `Device.udiCarrier.deviceIdentifier` is mapped to FHIR STU3 element `Device.udi.deviceIdentifier` as `Equivalent`."
}
]
},
{
"code": "Device.udiCarrier.issuer",
"display": "issuer",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.udi.issuer",
"display": "Device.udi.issuer",
"equivalence": "equivalent",
"comment": "Element `Device.udiCarrier.issuer` is mapped to FHIR STU3 element `Device.udi.issuer` as `Equivalent`."
}
]
},
{
"code": "Device.udiCarrier.jurisdiction",
"display": "jurisdiction",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.udi.jurisdiction",
"display": "Device.udi.jurisdiction",
"equivalence": "equivalent",
"comment": "Element `Device.udiCarrier.jurisdiction` is mapped to FHIR STU3 element `Device.udi.jurisdiction` as `Equivalent`."
}
]
},
{
"code": "Device.udiCarrier.carrierAIDC",
"display": "carrierAIDC",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.udi.carrierAIDC",
"display": "Device.udi.carrierAIDC",
"equivalence": "equivalent",
"comment": "Element `Device.udiCarrier.carrierAIDC` is mapped to FHIR STU3 element `Device.udi.carrierAIDC` as `Equivalent`.\nThe AIDC form of UDIs should be scanned or otherwise used for the identification of the device whenever possible to minimize errors in records resulting from manual transcriptions. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label."
}
]
},
{
"code": "Device.udiCarrier.carrierHRF",
"display": "carrierHRF",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.udi.carrierHRF",
"display": "Device.udi.carrierHRF",
"equivalence": "equivalent",
"comment": "Element `Device.udiCarrier.carrierHRF` is mapped to FHIR STU3 element `Device.udi.carrierHRF` as `Equivalent`.\nIf separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label."
}
]
},
{
"code": "Device.udiCarrier.entryType",
"display": "entryType",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.udi.entryType",
"display": "Device.udi.entryType",
"equivalence": "equivalent",
"comment": "Element `Device.udiCarrier.entryType` is mapped to FHIR STU3 element `Device.udi.entryType` as `Equivalent`."
}
]
},
{
"code": "Device.status",
"display": "status",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.status",
"display": "Device.status",
"equivalence": "equivalent",
"comment": "Element `Device.status` is mapped to FHIR STU3 element `Device.status` as `Equivalent`.\nThis element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid."
}
]
},
{
"code": "Device.manufacturer",
"display": "manufacturer",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.manufacturer",
"display": "Device.manufacturer",
"equivalence": "equivalent",
"comment": "Element `Device.manufacturer` is mapped to FHIR STU3 element `Device.manufacturer` as `Equivalent`."
}
]
},
{
"code": "Device.manufactureDate",
"display": "manufactureDate",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.manufactureDate",
"display": "Device.manufactureDate",
"equivalence": "equivalent",
"comment": "Element `Device.manufactureDate` is mapped to FHIR STU3 element `Device.manufactureDate` as `Equivalent`."
}
]
},
{
"code": "Device.expirationDate",
"display": "expirationDate",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.expirationDate",
"display": "Device.expirationDate",
"equivalence": "equivalent",
"comment": "Element `Device.expirationDate` is mapped to FHIR STU3 element `Device.expirationDate` as `Equivalent`."
}
]
},
{
"code": "Device.lotNumber",
"display": "lotNumber",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.lotNumber",
"display": "Device.lotNumber",
"equivalence": "equivalent",
"comment": "Element `Device.lotNumber` is mapped to FHIR STU3 element `Device.lotNumber` as `Equivalent`."
}
]
},
{
"code": "Device.deviceName",
"display": "deviceName",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.udi",
"display": "Device.udi",
"equivalence": "wider",
"comment": "Element `Device.deviceName` is mapped to FHIR STU3 element `Device.udi` as `SourceIsBroaderThanTarget`."
}
]
},
{
"code": "Device.modelNumber",
"display": "modelNumber",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.model",
"display": "Device.model",
"equivalence": "equivalent",
"comment": "Element `Device.modelNumber` is mapped to FHIR STU3 element `Device.model` as `Equivalent`."
}
]
},
{
"code": "Device.type",
"display": "type",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.type",
"display": "Device.type",
"equivalence": "equivalent",
"comment": "Element `Device.type` is mapped to FHIR STU3 element `Device.type` as `Equivalent`."
}
]
},
{
"code": "Device.version",
"display": "version",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.version",
"display": "Device.version",
"equivalence": "wider",
"comment": "Element `Device.version` is mapped to FHIR STU3 element `Device.version` as `SourceIsBroaderThanTarget`."
}
]
},
{
"code": "Device.patient",
"display": "patient",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.patient",
"display": "Device.patient",
"equivalence": "wider",
"comment": "Element `Device.patient` is mapped to FHIR STU3 element `Device.patient` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.patient` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `Device.patient` with unmapped reference targets: Patient."
}
]
},
{
"code": "Device.owner",
"display": "owner",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.owner",
"display": "Device.owner",
"equivalence": "wider",
"comment": "Element `Device.owner` is mapped to FHIR STU3 element `Device.owner` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.owner` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `Device.owner` with unmapped reference targets: Organization."
}
]
},
{
"code": "Device.contact",
"display": "contact",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.contact",
"display": "Device.contact",
"equivalence": "wider",
"comment": "Element `Device.contact` is mapped to FHIR STU3 element `Device.contact` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.contact` do not cover the following types: ContactPoint.\nThe mappings for `Device.contact` do not cover the following types based on type expansion: period, rank, system, use, value.\nused for troubleshooting etc."
}
]
},
{
"code": "Device.location",
"display": "location",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.location",
"display": "Device.location",
"equivalence": "wider",
"comment": "Element `Device.location` is mapped to FHIR STU3 element `Device.location` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.location` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4B element `Device.location` with unmapped reference targets: Location."
}
]
},
{
"code": "Device.url",
"display": "url",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.url",
"display": "Device.url",
"equivalence": "equivalent",
"comment": "Element `Device.url` is mapped to FHIR STU3 element `Device.url` as `Equivalent`.\nIf the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved."
}
]
},
{
"code": "Device.note",
"display": "note",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "wider"
}
],
"code": "Device.note",
"display": "Device.note",
"equivalence": "wider",
"comment": "Element `Device.note` is mapped to FHIR STU3 element `Device.note` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.note` do not cover the following types: Annotation.\nThe mappings for `Device.note` do not cover the following types based on type expansion: author[x], text, time."
}
]
},
{
"code": "Device.safety",
"display": "safety",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Device.safety",
"display": "Device.safety",
"equivalence": "equivalent",
"comment": "Element `Device.safety` is mapped to FHIR STU3 element `Device.safety` as `Equivalent`."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.meta",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.meta",
"display": "meta",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.meta` is mapped to FHIR STU3 element `Device.meta` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.meta` do not cover the following types: Meta.\nThe mappings for `Device.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, source, tag, versionId."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.text",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.text",
"display": "text",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.text` is mapped to FHIR STU3 element `Device.text` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.text` do not cover the following types: Narrative.\nThe mappings for `Device.text` do not cover the following types based on type expansion: div, status.\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.identifier",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.identifier",
"display": "identifier",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.identifier` is mapped to FHIR STU3 element `Device.identifier` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.identifier` do not cover the following types: Identifier.\nThe mappings for `Device.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value.\nThe barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.definition",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.definition",
"display": "definition",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.definition` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.definition` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.statusReason",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.statusReason",
"display": "statusReason",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.statusReason` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.statusReason` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.distinctIdentifier",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.distinctIdentifier",
"display": "distinctIdentifier",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.distinctIdentifier` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.distinctIdentifier` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nFor example, this applies to devices in the United States regulated under *Code of Federal Regulation 21CFR§1271.290(c)*."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.serialNumber",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.serialNumber",
"display": "serialNumber",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.serialNumber` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.serialNumber` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nAlphanumeric Maximum 20."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.deviceName.name",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.deviceName.name",
"display": "name",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.deviceName.name` has a context of Device.udi based on following the parent source element upwards and mapping to `Device`.\nElement `Device.deviceName.name` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.deviceName.type",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.deviceName.type",
"display": "type",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.deviceName.type` has a context of Device.udi based on following the parent source element upwards and mapping to `Device`.\nElement `Device.deviceName.type` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.partNumber",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.partNumber",
"display": "partNumber",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.partNumber` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.partNumber` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).\nAlphanumeric Maximum 20."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.specialization",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.specialization",
"display": "specialization",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.specialization` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.specialization` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "Device.specialization.systemType",
"display": "systemType",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension.extension:systemType",
"equivalence": "equivalent",
"comment": "Element `Device.specialization.systemType` is part of an existing definition because parent element `Device.specialization` requires a cross-version extension.\nElement `Device.specialization.systemType` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.specialization.systemType` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "Device.specialization.version",
"display": "version",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension.extension:version",
"equivalence": "equivalent",
"comment": "Element `Device.specialization.version` is part of an existing definition because parent element `Device.specialization` requires a cross-version extension.\nElement `Device.specialization.version` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.specialization.version` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.version.type",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.version.type",
"display": "type",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.version.type` has a context of Device.version based on following the parent source element upwards and mapping to `Device`.\nElement `Device.version.type` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.version.component",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.version.component",
"display": "component",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.version.component` has a context of Device.version based on following the parent source element upwards and mapping to `Device`.\nElement `Device.version.component` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.version.value",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.version.value",
"display": "value",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.version.value` has a context of Device.version based on following the parent source element upwards and mapping to `Device`.\nElement `Device.version.value` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.property",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.property",
"display": "property",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.property` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.property` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "Device.property.type",
"display": "type",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension.extension:type",
"equivalence": "equivalent",
"comment": "Element `Device.property.type` is part of an existing definition because parent element `Device.property` requires a cross-version extension.\nElement `Device.property.type` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.property.type` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "Device.property.valueQuantity",
"display": "valueQuantity",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension.extension:valueQuantity",
"equivalence": "equivalent",
"comment": "Element `Device.property.valueQuantity` is part of an existing definition because parent element `Device.property` requires a cross-version extension.\nElement `Device.property.valueQuantity` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.property.valueQuantity` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
},
{
"code": "Device.property.valueCode",
"display": "valueCode",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension.extension:valueCode",
"equivalence": "equivalent",
"comment": "Element `Device.property.valueCode` is part of an existing definition because parent element `Device.property` requires a cross-version extension.\nElement `Device.property.valueCode` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.property.valueCode` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.contact",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.contact",
"display": "contact",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.contact` is mapped to FHIR STU3 element `Device.contact` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.contact` do not cover the following types: ContactPoint.\nThe mappings for `Device.contact` do not cover the following types based on type expansion: period, rank, system, use, value.\nused for troubleshooting etc."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.note",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.note",
"display": "note",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.note` is mapped to FHIR STU3 element `Device.note` as `SourceIsBroaderThanTarget`.\nThe mappings for `Device.note` do not cover the following types: Annotation.\nThe mappings for `Device.note` do not cover the following types based on type expansion: author[x], text, time."
}
]
}
]
},
{
"source": "http://hl7.org/fhir/StructureDefinition/Device",
"sourceVersion": "4.3.0",
"target": "http://hl7.org/fhir/4.3/StructureDefinition/extension-Device.parent",
"targetVersion": "0.1.0",
"element": [
{
"code": "Device.parent",
"display": "parent",
"target": [
{
"modifierExtension": [
{
"url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
"valueCode": "equivalent"
}
],
"code": "Extension",
"equivalence": "equivalent",
"comment": "Element `Device.parent` has a context of Device based on following the parent source element upwards and mapping to `Device`.\nElement `Device.parent` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
}
]
}
]
}
]
}