FHIR IG analytics
| Package | hl7.fhir.uv.xver-r4.r4b |
| Resource Type | ValueSet |
| Id | ValueSet-R4-certainty-subcomponent-rating-for-R4B.json |
| FHIR Version | R4B |
| Source | http://hl7.org/fhir/uv/xver-r4.r4b/0.1.0/ValueSet-R4-certainty-subcomponent-rating-for-R4B.html |
| URL | http://hl7.org/fhir/uv/xver/ValueSet/R4-certainty-subcomponent-rating-for-R4B |
| Version | 0.1.0 |
| Status | active |
| Date | 2026-03-17T21:02:03.8104715+00:00 |
| Name | R4CertaintySubcomponentRatingForR4B |
| Title | Cross-version ValueSet R4.CertaintySubcomponentRating for use in FHIR R4B |
| Realm | uv |
| Authority | hl7 |
| Description | This cross-version ValueSet represents content from `http://hl7.org/fhir/ValueSet/certainty-subcomponent-rating|4.0.1` for use in FHIR R4B. |
| Purpose | This value set is part of the cross-version definitions generated to enable use of the
value set `http://hl7.org/fhir/ValueSet/certainty-subcomponent-rating|4.0.1` as defined in FHIR R4
in FHIR R4B.
The source value set is bound to the following FHIR R4 elements:
* `EffectEvidenceSynthesis.certainty.certaintySubcomponent.rating`
* `RiskEvidenceSynthesis.certainty.certaintySubcomponent.rating`
Note that all concepts are included in this cross-version definition because no concepts have compatible representations
Following are the generation technical comments:
FHIR ValueSet `http://hl7.org/fhir/ValueSet/certainty-subcomponent-rating|4.0.1`, defined in FHIR R4 does not have any mapping to FHIR R4B |
Resources that use this resource
Resources that this resource uses
Narrative
Note: links and images are rebased to the (stated) source
This value set expansion contains 11 concepts.
| System | Version | Code | Display | Definition |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | absent | absent | possible reason for increasing quality rating was checked and found to be absent. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | critical-concern | critical concern | critical concern. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | downcode1 | reduce rating: -1 | reduce quality rating by 1. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | downcode2 | reduce rating: -2 | reduce quality rating by 2. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | downcode3 | reduce rating: -3 | reduce quality rating by 3. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | no-change | no change to rating | no change to quality rating. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | no-concern | no serious concern | no serious concern. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | present | present | possible reason for increasing quality rating was checked and found to bepresent. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | serious-concern | serious concern | serious concern. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | upcode1 | increase rating: +1 | increase quality rating by 1. |
http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating | 4.0.1 | upcode2 | increase rating: +2 | increase quality rating by 2. |
Source1
{
"resourceType": "ValueSet",
"id": "R4-certainty-subcomponent-rating-for-R4B",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 0
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "cds"
},
{
"extension": [
{
"url": "packageId",
"valueId": "hl7.fhir.uv.xver-r4.r4b"
},
{
"url": "version",
"valueString": "0.1.0"
},
{
"url": "uri",
"valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4.r4b"
}
],
"url": "http://hl7.org/fhir/StructureDefinition/package-source"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "trial-use",
"_valueCode": {
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4.r4b"
}
]
}
}
],
"url": "http://hl7.org/fhir/uv/xver/ValueSet/R4-certainty-subcomponent-rating-for-R4B",
"version": "0.1.0",
"name": "R4CertaintySubcomponentRatingForR4B",
"title": "Cross-version ValueSet R4.CertaintySubcomponentRating for use in FHIR R4B",
"status": "active",
"experimental": false,
"date": "2026-03-17T21:02:03.8104715+00:00",
"publisher": "Clinical Decision Support",
"contact": [
{
"name": "Clinical Decision Support",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/dss"
}
]
}
],
"description": "This cross-version ValueSet represents content from `http://hl7.org/fhir/ValueSet/certainty-subcomponent-rating|4.0.1` for use in FHIR R4B.",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001",
"display": "World"
}
]
}
],
"purpose": "This value set is part of the cross-version definitions generated to enable use of the\r\nvalue set `http://hl7.org/fhir/ValueSet/certainty-subcomponent-rating|4.0.1` as defined in FHIR R4\r\nin FHIR R4B.\r\n\r\nThe source value set is bound to the following FHIR R4 elements:\r\n* `EffectEvidenceSynthesis.certainty.certaintySubcomponent.rating`\n* `RiskEvidenceSynthesis.certainty.certaintySubcomponent.rating`\r\n\r\nNote that all concepts are included in this cross-version definition because no concepts have compatible representations\r\n\r\nFollowing are the generation technical comments:\r\n\nFHIR ValueSet `http://hl7.org/fhir/ValueSet/certainty-subcomponent-rating|4.0.1`, defined in FHIR R4 does not have any mapping to FHIR R4B",
"compose": {
"include": [
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"concept": [
{
"code": "absent",
"display": "absent"
},
{
"code": "critical-concern",
"display": "critical concern"
},
{
"code": "downcode1",
"display": "reduce rating: -1"
},
{
"code": "downcode2",
"display": "reduce rating: -2"
},
{
"code": "downcode3",
"display": "reduce rating: -3"
},
{
"code": "no-change",
"display": "no change to rating"
},
{
"code": "no-concern",
"display": "no serious concern"
},
{
"code": "present",
"display": "present"
},
{
"code": "serious-concern",
"display": "serious concern"
},
{
"code": "upcode1",
"display": "increase rating: +1"
},
{
"code": "upcode2",
"display": "increase rating: +2"
}
]
}
]
},
"expansion": {
"timestamp": "2026-03-17T21:02:03.8104715+00:00",
"contains": [
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "absent",
"display": "absent"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "critical-concern",
"display": "critical concern"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "downcode1",
"display": "reduce rating: -1"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "downcode2",
"display": "reduce rating: -2"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "downcode3",
"display": "reduce rating: -3"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "no-change",
"display": "no change to rating"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "no-concern",
"display": "no serious concern"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "present",
"display": "present"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "serious-concern",
"display": "serious concern"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "upcode1",
"display": "increase rating: +1"
},
{
"system": "http://terminology.hl7.org/CodeSystem/certainty-subcomponent-rating",
"version": "4.0.1",
"code": "upcode2",
"display": "increase rating: +2"
}
]
}
}