FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r4.r4b
Resource TypeCodeSystem
IdCodeSystem-device-statement-status.json
FHIR VersionR4B
Sourcehttp://hl7.org/fhir/uv/xver-r4.r4b/0.1.0/CodeSystem-device-statement-status.html
URLhttp://hl7.org/fhir/device-statement-status
Version4.0.1
Statusdraft
Date2019-10-31T17:29:23-05:00
NameDeviceUseStatementStatus
TitleDeviceUseStatementStatus
Realmuv
Authorityhl7
DescriptionA coded concept indicating the current status of the Device Usage.
Contentcomplete

Resources that use this resource

ConceptMap
hl7.fhir.uv.xver-r5.r4#0.1.0R5-deviceusage-status-for-R4-device-statement-statusCross-version ConceptMap for ValueSet R5-deviceusage-status-for-R4-device-statement-status from FHIR R5 to FHIR R4
hl7.fhir.uv.xver-r5.r3#0.1.0R5-deviceusage-status-for-R3-device-statement-statusCross-version ConceptMap for ValueSet R5-deviceusage-status-for-R3-device-statement-status from FHIR R5 to FHIR STU3
hl7.fhir.uv.xver-r5.r4b#0.1.0R5-deviceusage-status-for-R4B-device-statement-statusCross-version ConceptMap for ValueSet R5-deviceusage-status-for-R4B-device-statement-status from FHIR R5 to FHIR R4B
kbv.mio.ueberleitungsbogen#1.0.0KBV_CM_MIO_ULB_OverviewKBV_CM_MIO_ULB_Overview
ValueSet
hl7.fhir.uv.xver-r3.r4b.r4#0.0.1-snapshot-2R3-device-statement-status-for-R4BCross-version VS for R3.DeviceUseStatementStatus for use in FHIR R4B
hl7.fhir.uv.xver-r4.r4b.r4b#0.0.1-snapshot-2R4-device-statement-status-for-R4BCross-version VS for R4.DeviceUseStatementStatus for use in FHIR R4B

Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: CodeSystem device-statement-status

This case-sensitive code system http://hl7.org/fhir/device-statement-status defines the following codes:

CodeDisplayDefinition
active ActiveThe device is still being used.
completed CompletedThe device is no longer being used.
entered-in-error Entered in ErrorThe statement was recorded incorrectly.
intended IntendedThe device may be used at some time in the future.
stopped StoppedActions implied by the statement have been permanently halted, before all of them occurred.
on-hold On HoldActions implied by the statement have been temporarily halted, but are expected to continue later. May also be called "suspended".

Source1

{
  "resourceType": "CodeSystem",
  "id": "device-statement-status",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0
    },
    {
      "extension": [
        {
          "url": "packageId",
          "valueId": "hl7.fhir.uv.xver-r4.r4b"
        },
        {
          "url": "version",
          "valueString": "0.1.0"
        },
        {
          "url": "uri",
          "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4.r4b"
        }
      ],
      "url": "http://hl7.org/fhir/StructureDefinition/package-source"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "oo"
    }
  ],
  "url": "http://hl7.org/fhir/device-statement-status",
  "version": "4.0.1",
  "name": "DeviceUseStatementStatus",
  "title": "DeviceUseStatementStatus",
  "status": "draft",
  "experimental": false,
  "date": "2019-10-31T17:29:23-05:00",
  "publisher": "Orders and Observations",
  "contact": [
    {
      "name": "Orders and Observations",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/orders"
        }
      ]
    }
  ],
  "description": "A coded concept indicating the current status of the Device Usage.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "caseSensitive": true,
  "valueSet": "http://hl7.org/fhir/ValueSet/device-statement-status|4.3.0",
  "content": "complete",
  "concept": [
    {
      "code": "active",
      "display": "Active",
      "definition": "The device is still being used."
    },
    {
      "code": "completed",
      "display": "Completed",
      "definition": "The device is no longer being used."
    },
    {
      "code": "entered-in-error",
      "display": "Entered in Error",
      "definition": "The statement was recorded incorrectly."
    },
    {
      "code": "intended",
      "display": "Intended",
      "definition": "The device may be used at some time in the future."
    },
    {
      "code": "stopped",
      "display": "Stopped",
      "definition": "Actions implied by the statement have been permanently halted, before all of them occurred."
    },
    {
      "code": "on-hold",
      "display": "On Hold",
      "definition": "Actions implied by the statement have been temporarily halted, but are expected to continue later. May also be called \"suspended\"."
    }
  ]
}