FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r4.r4b
Resource TypeValueSet
IdValueSet-R4-v3-hl7V3Conformance-for-R4B.json
FHIR VersionR4B
Sourcehttp://hl7.org/fhir/uv/xver-r4.r4b/0.0.1-snapshot-2/ValueSet-R4-v3-hl7V3Conformance-for-R4B.html
URLhttp://hl7.org/fhir/4.0/ValueSet/R4-v3-hl7V3Conformance-for-R4B
Version0.0.1-snapshot-2
Statusactive
Date2025-09-01T22:36:21.919897+10:00
NameR4_v3_hl7V3Conformance_for_R4B
TitleCross-version VS for R4.v3.hl7V3Conformance for use in FHIR R4B
Realmuv
Authorityhl7
DescriptionThis cross-version ValueSet represents concepts from http://terminology.hl7.org/ValueSet/v3-hl7V3Conformance|2018-08-12 for use in FHIR R4B. Concepts not present here have direct `equivalent` mappings crossing all versions from R4 to R4B.

Resources that use this resource

No resources found


Resources that this resource uses

CodeSystem
v3-hl7V3ConformanceHL7V3Conformance

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ValueSet R4-v3-hl7V3Conformance-for-R4B

This value set expansion contains 6 concepts.

CodeSystemDisplayDefinition
  Ihttp://terminology.hl7.org/CodeSystem/v3-hl7V3Conformanceignored**Description:** Implementers receiving this property must not raise an error if the data is received, but will not perform any useful function with the data. This conformance level is not used in profiles or other artifacts that are specific to the "sender" or "initiator" of a communication.
  NPhttp://terminology.hl7.org/CodeSystem/v3-hl7V3Conformancenot permitted**Description:** All implementers are prohibited from transmitting this content, and may raise an error if they receive it.
  Rhttp://terminology.hl7.org/CodeSystem/v3-hl7V3Conformancerequired**Description:** All implementers must support this property. I.e. they must be able to transmit, or to receive and usefully handle the concept.
  RChttp://terminology.hl7.org/CodeSystem/v3-hl7V3Conformancerequired for consumer**Description:** The element is considered "required" (i.e. must be supported) from the perspective of systems that consume instances, but is "undetermined" for systems that generate instances. Used only as part of specifications that define both initiator and consumer expectations.
  RIhttp://terminology.hl7.org/CodeSystem/v3-hl7V3Conformancerequired for initiator**Description:** The element is considered "required" (i.e. must be supported) from the perspective of systems that generate instances, but is "undetermined" for systems that consume instances. Used only as part of specifications that define both initiator and consumer expectations.
  Uhttp://terminology.hl7.org/CodeSystem/v3-hl7V3Conformanceundetermined**Description:** The conformance expectations for this element have not yet been determined.

Source1

{
  "resourceType": "ValueSet",
  "id": "R4-v3-hl7V3Conformance-for-R4B",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "vocab"
    },
    {
      "extension": [
        {
          "url": "packageId",
          "valueId": "hl7.fhir.uv.xver-r4.r4b"
        },
        {
          "url": "version",
          "valueString": "0.0.1-snapshot-2"
        }
      ],
      "url": "http://hl7.org/fhir/StructureDefinition/package-source"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/4.0/ImplementationGuide/hl7.fhir.uv.xver-r4.r4b"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/4.0/ValueSet/R4-v3-hl7V3Conformance-for-R4B",
  "version": "0.0.1-snapshot-2",
  "name": "R4_v3_hl7V3Conformance_for_R4B",
  "title": "Cross-version VS for R4.v3.hl7V3Conformance for use in FHIR R4B",
  "status": "active",
  "experimental": false,
  "date": "2025-09-01T22:36:21.919897+10:00",
  "publisher": "HL7 International / Terminology Infrastructure",
  "contact": [
    {
      "name": "HL7 International / Terminology Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/Vocab"
        }
      ]
    }
  ],
  "description": "This cross-version ValueSet represents concepts from http://terminology.hl7.org/ValueSet/v3-hl7V3Conformance|2018-08-12 for use in FHIR R4B. Concepts not present here have direct `equivalent` mappings crossing all versions from R4 to R4B.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "compose": {
    "include": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance",
        "version": "2018-08-12",
        "concept": [
          {
            "code": "I",
            "display": "ignored"
          },
          {
            "code": "NP",
            "display": "not permitted"
          },
          {
            "code": "R",
            "display": "required"
          },
          {
            "code": "RC",
            "display": "required for consumer"
          },
          {
            "code": "RI",
            "display": "required for initiator"
          },
          {
            "code": "U",
            "display": "undetermined"
          }
        ]
      }
    ]
  },
  "expansion": {
    "timestamp": "2025-09-01T22:36:21.919898+10:00",
    "contains": [
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance",
        "version": "2018-08-12",
        "code": "I",
        "display": "ignored"
      },
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance",
        "version": "2018-08-12",
        "code": "NP",
        "display": "not permitted"
      },
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance",
        "version": "2018-08-12",
        "code": "R",
        "display": "required"
      },
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance",
        "version": "2018-08-12",
        "code": "RC",
        "display": "required for consumer"
      },
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance",
        "version": "2018-08-12",
        "code": "RI",
        "display": "required for initiator"
      },
      {
        "system": "http://terminology.hl7.org/CodeSystem/v3-hl7V3Conformance",
        "version": "2018-08-12",
        "code": "U",
        "display": "undetermined"
      }
    ]
  }
}