FHIR IG analytics| Package | hl7.fhir.uv.xver-r4.r4b |
| Resource Type | CodeSystem |
| Id | CodeSystem-issue-severity.json |
| FHIR Version | R4B |
| Source | http://hl7.org/fhir/uv/xver-r4.r4b/0.0.1-snapshot-2/CodeSystem-issue-severity.html |
| URL | http://hl7.org/fhir/issue-severity |
| Version | 4.0.1 |
| Status | active |
| Date | 2019-11-01T08:29:23+10:00 |
| Name | IssueSeverity |
| Title | IssueSeverity |
| Realm | uv |
| Authority | hl7 |
| Description | How the issue affects the success of the action. |
| Content | complete |
| CodeSystem | |
| audit-event-outcome-cs | Audit event outcome translations |
| ConceptMap | |
| twcdc-issueseverity | 系統回應訊息-問題嚴重性對應 |
| VSDMTDSCodeIssueSeverity | VSDMTDSCode zu IssueSeverity |
| ValueSet | |
| audit-event-outcome-vs | Audit event outcome |
| R4-issue-severity-for-R4B | Cross-version VS for R4.IssueSeverity for use in FHIR R4B |
| R5-audit-event-outcome-for-R4B | Cross-version VS for R5.AuditEventOutcome for use in FHIR R4B |
| R5-issue-severity-for-R4B | Cross-version VS for R5.IssueSeverity for use in FHIR R4B |
| R2-issue-severity-for-R4B | Cross-version VS for R2.IssueSeverity for use in FHIR R4B |
| R3-issue-severity-for-R4B | Cross-version VS for R3.IssueSeverity for use in FHIR R4B |
| R4-issue-severity-for-R5 | Cross-version VS for R4.IssueSeverity for use in FHIR R5 |
| R5-audit-event-outcome-for-R4 | Cross-version VS for R5.AuditEventOutcome for use in FHIR R4 |
| R5-issue-severity-for-R4 | Cross-version VS for R5.IssueSeverity for use in FHIR R4 |
| R2-issue-severity-for-R5 | Cross-version VS for R2.IssueSeverity for use in FHIR R5 |
| R3-issue-severity-for-R5 | Cross-version VS for R3.IssueSeverity for use in FHIR R5 |
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: CodeSystem issue-severity
This case-sensitive code system http://hl7.org/fhir/issue-severity defines the following codes:
{
"resourceType": "CodeSystem",
"id": "issue-severity",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "normative"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-normative-version",
"valueCode": "4.0.0"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 5
},
{
"extension": [
{
"url": "packageId",
"valueId": "hl7.fhir.uv.xver-r4.r4b"
},
{
"url": "version",
"valueString": "0.0.1-snapshot-2"
}
],
"url": "http://hl7.org/fhir/StructureDefinition/package-source"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "fhir"
}
],
"url": "http://hl7.org/fhir/issue-severity",
"version": "4.0.1",
"name": "IssueSeverity",
"title": "IssueSeverity",
"status": "active",
"experimental": false,
"date": "2019-11-01T08:29:23+10:00",
"publisher": "FHIR Infrastructure",
"contact": [
{
"name": "FHIR Infrastructure",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/fiwg"
}
]
}
],
"description": "How the issue affects the success of the action.",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001",
"display": "World"
}
]
}
],
"caseSensitive": true,
"valueSet": "http://hl7.org/fhir/ValueSet/issue-severity|4.3.0",
"content": "complete",
"concept": [
{
"code": "fatal",
"display": "Fatal",
"definition": "The issue caused the action to fail and no further checking could be performed."
},
{
"code": "error",
"display": "Error",
"definition": "The issue is sufficiently important to cause the action to fail."
},
{
"code": "warning",
"display": "Warning",
"definition": "The issue is not important enough to cause the action to fail but may cause it to be performed suboptimally or in a way that is not as desired."
},
{
"code": "information",
"display": "Information",
"definition": "The issue has no relation to the degree of success of the action."
}
]
}