FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r4.r3
Resource TypeConceptMap
IdConceptMap-R4-ImagingStudy-element-map-to-R3.json
FHIR VersionR3
Sourcehttp://hl7.org/fhir/uv/xver-r4.r3/0.1.0/ConceptMap-R4-ImagingStudy-element-map-to-R3.html
URLhttp://hl7.org/fhir/uv/xver/ConceptMap/R4-ImagingStudy-element-map-to-R3
Version0.1.0
Statusactive
Date2026-03-17T16:03:32.3998759-05:00
NameR4ImagingStudyElementMapToR3
TitleCross-version mapping for FHIR R4 ImagingStudy to FHIR STU3 ImagingStudy
Realmuv
Authorityhl7
DescriptionThis ConceptMap represents cross-version mappings for elements from a FHIR R4 ImagingStudy to FHIR STU3.

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
hl7.fhir.uv.xver-r4.r3#0.1.0extension-ImagingStudy.locationR4: Where ImagingStudy occurred (new)
hl7.fhir.uv.xver-r4.r3#0.1.0extension-ImagingStudy.noteR4: User-defined comments (new)
hl7.fhir.uv.xver-r4.r5#0.1.0extension-ImagingStudy.reasonReferenceR4: Why was study performed (new)
hl7.fhir.uv.xver-r4.r3#0.1.0extension-ImagingStudy.series.instance.sopClassR4: sopClass additional types
hl7.fhir.uv.xver-r4.r3#0.1.0extension-ImagingStudy.series.instance.uidR4: DICOM SOP Instance UID additional types
hl7.fhir.uv.xver-r4.r3#0.1.0extension-ImagingStudy.series.performer.actorR4: Who performed the series (new)
hl7.fhir.uv.xver-r4.r3#0.1.0extension-ImagingStudy.series.performer.functionR4: Type of performance (new)
hl7.fhir.uv.xver-r4.r3#0.1.0extension-ImagingStudy.series.specimenR4: Specimen imaged (new)
hl7.fhir.uv.xver-r4.r3#0.1.0extension-ImagingStudy.series.uidR4: DICOM Series Instance UID for the series additional types

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap R4-ImagingStudy-element-map-to-R3

Mapping from http://hl7.org/fhir/4.0 to http://hl7.org/fhir/3.0


Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to http://hl7.org/fhir/StructureDefinition/ImagingStudy|3.0.2

Source Concept DetailsRelationshipTarget Concept DetailsComment
Codes from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1Codes from http://hl7.org/fhir/StructureDefinition/ImagingStudy|3.0.2
ImagingStudy.metametais equivalent toImagingStudy.metaImagingStudy.metaElement `ImagingStudy.meta` is mapped to FHIR STU3 element `ImagingStudy.meta` as `Equivalent`.
ImagingStudy.implicitRulesimplicitRulesis equivalent toImagingStudy.implicitRulesImagingStudy.implicitRulesElement `ImagingStudy.implicitRules` is mapped to FHIR STU3 element `ImagingStudy.implicitRules` as `Equivalent`. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.
ImagingStudy.languagelanguageis equivalent toImagingStudy.languageImagingStudy.languageElement `ImagingStudy.language` is mapped to FHIR STU3 element `ImagingStudy.language` as `Equivalent`. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).
ImagingStudy.texttextis equivalent toImagingStudy.textImagingStudy.textElement `ImagingStudy.text` is mapped to FHIR STU3 element `ImagingStudy.text` as `Equivalent`. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.
ImagingStudy.containedcontainedis equivalent toImagingStudy.containedImagingStudy.containedElement `ImagingStudy.contained` is mapped to FHIR STU3 element `ImagingStudy.contained` as `Equivalent`. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.
ImagingStudy.identifieridentifieris related toImagingStudy.accessionImagingStudy.accessionElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`. See discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type.
is equivalent toImagingStudy.identifierImagingStudy.identifierElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`. See discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type.
is related toImagingStudy.uidImagingStudy.uidElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`. Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`. See discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type.
ImagingStudy.statusstatusis equivalent toImagingStudy.availabilityImagingStudy.availabilityElement `ImagingStudy.status` is mapped to FHIR STU3 element `ImagingStudy.availability` as `Equivalent`. Unknown does not represent "other" - one of the defined statuses must apply. Unknown is used when the authoring system is not sure what the current status is.
ImagingStudy.modalitymodalityis equivalent toImagingStudy.modalityListImagingStudy.modalityListElement `ImagingStudy.modality` is mapped to FHIR STU3 element `ImagingStudy.modalityList` as `Equivalent`.
ImagingStudy.subjectsubjectmaps to wider conceptImagingStudy.patientImagingStudy.patientElement `ImagingStudy.subject` is mapped to FHIR STU3 element `ImagingStudy.patient` as `SourceIsBroaderThanTarget`. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4 element `ImagingStudy.subject` with unmapped reference targets: Device, Group. QA phantoms can be recorded with a Device; multiple subjects (such as mice) can be recorded with a Group.
ImagingStudy.encounterencounteris equivalent toImagingStudy.contextImagingStudy.contextElement `ImagingStudy.encounter` is mapped to FHIR STU3 element `ImagingStudy.context` as `Equivalent`. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission test).
ImagingStudy.startedstartedis equivalent toImagingStudy.startedImagingStudy.startedElement `ImagingStudy.started` is mapped to FHIR STU3 element `ImagingStudy.started` as `Equivalent`.
ImagingStudy.basedOnbasedOnmaps to wider conceptImagingStudy.basedOnImagingStudy.basedOnElement `ImagingStudy.basedOn` is mapped to FHIR STU3 element `ImagingStudy.basedOn` as `SourceIsBroaderThanTarget`. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4 element `ImagingStudy.basedOn` with unmapped reference targets: Appointment, AppointmentResponse, ServiceRequest, Task.
ImagingStudy.referrerreferrermaps to wider conceptImagingStudy.referrerImagingStudy.referrerElement `ImagingStudy.referrer` is mapped to FHIR STU3 element `ImagingStudy.referrer` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.referrer` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4 element `ImagingStudy.referrer` with unmapped reference targets: PractitionerRole.
ImagingStudy.interpreterinterpretermaps to wider conceptImagingStudy.interpreterImagingStudy.interpreterElement `ImagingStudy.interpreter` is mapped to FHIR STU3 element `ImagingStudy.interpreter` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.interpreter` do not cover the following types based on type expansion: display, identifier, reference, type. The standard extension `alternate-reference` has been mapped as the representation of FHIR R4 element `ImagingStudy.interpreter` with unmapped reference targets: PractitionerRole.
ImagingStudy.endpointendpointis equivalent toImagingStudy.endpointImagingStudy.endpointElement `ImagingStudy.endpoint` is mapped to FHIR STU3 element `ImagingStudy.endpoint` as `Equivalent`. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG), formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances; or IHE Invoke Image Display (IID), which provides standard invocation of an imaging web viewer.
ImagingStudy.numberOfSeriesnumberOfSeriesis equivalent toImagingStudy.numberOfSeriesImagingStudy.numberOfSeriesElement `ImagingStudy.numberOfSeries` is mapped to FHIR STU3 element `ImagingStudy.numberOfSeries` as `Equivalent`.
ImagingStudy.numberOfInstancesnumberOfInstancesis equivalent toImagingStudy.numberOfInstancesImagingStudy.numberOfInstancesElement `ImagingStudy.numberOfInstances` is mapped to FHIR STU3 element `ImagingStudy.numberOfInstances` as `Equivalent`.
ImagingStudy.procedureReferenceprocedureReferenceis equivalent toImagingStudy.procedureReferenceImagingStudy.procedureReferenceElement `ImagingStudy.procedureReference` is mapped to FHIR STU3 element `ImagingStudy.procedureReference` as `SourceIsNarrowerThanTarget`.
ImagingStudy.procedureCodeprocedureCodeis equivalent toImagingStudy.procedureCodeImagingStudy.procedureCodeElement `ImagingStudy.procedureCode` is mapped to FHIR STU3 element `ImagingStudy.procedureCode` as `Equivalent`.
ImagingStudy.reasonCodereasonCodeis equivalent toImagingStudy.reasonImagingStudy.reasonElement `ImagingStudy.reasonCode` is mapped to FHIR STU3 element `ImagingStudy.reason` as `SourceIsBroaderThanTarget`.
ImagingStudy.descriptiondescriptionis equivalent toImagingStudy.descriptionImagingStudy.descriptionElement `ImagingStudy.description` is mapped to FHIR STU3 element `ImagingStudy.description` as `Equivalent`.
ImagingStudy.seriesseriesmaps to wider conceptImagingStudy.seriesImagingStudy.seriesElement `ImagingStudy.series` is mapped to FHIR STU3 element `ImagingStudy.series` as `Equivalent`.
ImagingStudy.series.uiduidmaps to wider conceptImagingStudy.series.uidImagingStudy.series.uidElement `ImagingStudy.series.uid` is mapped to FHIR STU3 element `ImagingStudy.series.uid` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.uid` do not cover the following types: id. The mappings for `ImagingStudy.series.uid` do not cover the following types based on type expansion: value. See [DICOM PS3.3 C.7.3](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.7.3.html).
ImagingStudy.series.numbernumberis equivalent toImagingStudy.series.numberImagingStudy.series.numberElement `ImagingStudy.series.number` is mapped to FHIR STU3 element `ImagingStudy.series.number` as `Equivalent`.
ImagingStudy.series.modalitymodalityis equivalent toImagingStudy.series.modalityImagingStudy.series.modalityElement `ImagingStudy.series.modality` is mapped to FHIR STU3 element `ImagingStudy.series.modality` as `Equivalent`.
ImagingStudy.series.descriptiondescriptionis equivalent toImagingStudy.series.descriptionImagingStudy.series.descriptionElement `ImagingStudy.series.description` is mapped to FHIR STU3 element `ImagingStudy.series.description` as `Equivalent`.
ImagingStudy.series.numberOfInstancesnumberOfInstancesis equivalent toImagingStudy.series.numberOfInstancesImagingStudy.series.numberOfInstancesElement `ImagingStudy.series.numberOfInstances` is mapped to FHIR STU3 element `ImagingStudy.series.numberOfInstances` as `Equivalent`.
ImagingStudy.series.endpointendpointis equivalent toImagingStudy.series.endpointImagingStudy.series.endpointElement `ImagingStudy.series.endpoint` is mapped to FHIR STU3 element `ImagingStudy.series.endpoint` as `Equivalent`. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; and DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances.
ImagingStudy.series.bodySitebodySiteis equivalent toImagingStudy.series.bodySiteImagingStudy.series.bodySiteElement `ImagingStudy.series.bodySite` is mapped to FHIR STU3 element `ImagingStudy.series.bodySite` as `Equivalent`.
ImagingStudy.series.lateralitylateralityis equivalent toImagingStudy.series.lateralityImagingStudy.series.lateralityElement `ImagingStudy.series.laterality` is mapped to FHIR STU3 element `ImagingStudy.series.laterality` as `Equivalent`.
ImagingStudy.series.startedstartedis equivalent toImagingStudy.series.startedImagingStudy.series.startedElement `ImagingStudy.series.started` is mapped to FHIR STU3 element `ImagingStudy.series.started` as `Equivalent`.
ImagingStudy.series.performerperformermaps to wider conceptImagingStudy.series.performerImagingStudy.series.performerElement `ImagingStudy.series.performer` is mapped to FHIR STU3 element `ImagingStudy.series.performer` as `Equivalent`. If the person who performed the series is not known, their Organization may be recorded. A patient, or related person, may be the performer, e.g. for patient-captured images.
ImagingStudy.series.instanceinstancemaps to wider conceptImagingStudy.series.instanceImagingStudy.series.instanceElement `ImagingStudy.series.instance` is mapped to FHIR STU3 element `ImagingStudy.series.instance` as `Equivalent`.
ImagingStudy.series.instance.uiduidmaps to wider conceptImagingStudy.series.instance.uidImagingStudy.series.instance.uidElement `ImagingStudy.series.instance.uid` is mapped to FHIR STU3 element `ImagingStudy.series.instance.uid` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.instance.uid` do not cover the following types: id. The mappings for `ImagingStudy.series.instance.uid` do not cover the following types based on type expansion: value. See [DICOM PS3.3 C.12.1](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.12.html#sect_C.12.1).
ImagingStudy.series.instance.sopClasssopClassmaps to wider conceptImagingStudy.series.instance.sopClassImagingStudy.series.instance.sopClassElement `ImagingStudy.series.instance.sopClass` is mapped to FHIR STU3 element `ImagingStudy.series.instance.sopClass` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types: Coding. The mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types based on type expansion: code, display, system, userSelected, version.
ImagingStudy.series.instance.numbernumberis equivalent toImagingStudy.series.instance.numberImagingStudy.series.instance.numberElement `ImagingStudy.series.instance.number` is mapped to FHIR STU3 element `ImagingStudy.series.instance.number` as `Equivalent`.
ImagingStudy.series.instance.titletitleis equivalent toImagingStudy.series.instance.titleImagingStudy.series.instance.titleElement `ImagingStudy.series.instance.title` is mapped to FHIR STU3 element `ImagingStudy.series.instance.title` as `Equivalent`. Particularly for post-acquisition analytic objects, such as SR, presentation states, value mapping, etc.

Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: Where ImagingStudy occurred (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.location (location)maps to wider conceptExtension (R4: Where ImagingStudy occurred (new))Element `ImagingStudy.location` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.location` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: Why was study performed (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.reasonReference (reasonReference)maps to wider conceptExtension (R4: Why was study performed (new))Element `ImagingStudy.reasonReference` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.reasonReference` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: User-defined comments (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.note (note)maps to wider conceptExtension (R4: User-defined comments (new))Element `ImagingStudy.note` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.note` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: DICOM Series Instance UID for the series additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.uid (uid)is equivalent toExtension (R4: DICOM Series Instance UID for the series additional types)Element `ImagingStudy.series.uid` is mapped to FHIR STU3 element `ImagingStudy.series.uid` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.uid` do not cover the following types: id. The mappings for `ImagingStudy.series.uid` do not cover the following types based on type expansion: value. See [DICOM PS3.3 C.7.3](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.7.3.html).

Group 6 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: Specimen imaged (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.specimen (specimen)maps to wider conceptExtension (R4: Specimen imaged (new))Element `ImagingStudy.series.specimen` has a context of ImagingStudy.series based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.series.specimen` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 7 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: Type of performance (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.performer.function (function)maps to wider conceptExtension (R4: Type of performance (new))Element `ImagingStudy.series.performer.function` has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.series.performer.function` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 8 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: Who performed the series (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.performer.actor (actor)maps to wider conceptExtension (R4: Who performed the series (new))Element `ImagingStudy.series.performer.actor` has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to `ImagingStudy`. Element `ImagingStudy.series.performer.actor` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element).

Group 9 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: DICOM SOP Instance UID additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.instance.uid (uid)is equivalent toExtension (R4: DICOM SOP Instance UID additional types)Element `ImagingStudy.series.instance.uid` is mapped to FHIR STU3 element `ImagingStudy.series.instance.uid` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.instance.uid` do not cover the following types: id. The mappings for `ImagingStudy.series.instance.uid` do not cover the following types based on type expansion: value. See [DICOM PS3.3 C.12.1](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.12.html#sect_C.12.1).

Group 10 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingStudy|4.0.1 to R4: sopClass additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingStudy.series.instance.sopClass (sopClass)is equivalent toExtension (R4: sopClass additional types)Element `ImagingStudy.series.instance.sopClass` is mapped to FHIR STU3 element `ImagingStudy.series.instance.sopClass` as `SourceIsBroaderThanTarget`. The mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types: Coding. The mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types based on type expansion: code, display, system, userSelected, version.

Source1

{
  "resourceType": "ConceptMap",
  "id": "R4-ImagingStudy-element-map-to-R3",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4.r3"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r4.r3"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ConceptMap/R4-ImagingStudy-element-map-to-R3",
  "version": "0.1.0",
  "name": "R4ImagingStudyElementMapToR3",
  "title": "Cross-version mapping for FHIR R4 ImagingStudy to FHIR STU3 ImagingStudy",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T16:03:32.3998759-05:00",
  "contact": [
    {
      "name": "FHIR Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "This ConceptMap represents cross-version mappings for elements from a FHIR R4 ImagingStudy to FHIR STU3.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "sourceUri": "http://hl7.org/fhir/4.0",
  "targetUri": "http://hl7.org/fhir/3.0",
  "group": [
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "targetVersion": "3.0.2",
      "element": [
        {
          "code": "ImagingStudy.meta",
          "display": "meta",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.meta",
              "display": "ImagingStudy.meta",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.meta` is mapped to FHIR STU3 element `ImagingStudy.meta` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.implicitRules",
          "display": "implicitRules",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.implicitRules",
              "display": "ImagingStudy.implicitRules",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.implicitRules` is mapped to FHIR STU3 element `ImagingStudy.implicitRules` as `Equivalent`.\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc."
            }
          ]
        },
        {
          "code": "ImagingStudy.language",
          "display": "language",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.language",
              "display": "ImagingStudy.language",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.language` is mapped to FHIR STU3 element `ImagingStudy.language` as `Equivalent`.\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
            }
          ]
        },
        {
          "code": "ImagingStudy.text",
          "display": "text",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.text",
              "display": "ImagingStudy.text",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.text` is mapped to FHIR STU3 element `ImagingStudy.text` as `Equivalent`.\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied).  This may be necessary for data from legacy systems where information is captured as a \"text blob\" or where text is additionally entered raw or narrated and encoded information is added later."
            }
          ]
        },
        {
          "code": "ImagingStudy.contained",
          "display": "contained",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.contained",
              "display": "ImagingStudy.contained",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.contained` is mapped to FHIR STU3 element `ImagingStudy.contained` as `Equivalent`.\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels."
            }
          ]
        },
        {
          "code": "ImagingStudy.identifier",
          "display": "identifier",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "ImagingStudy.accession",
              "display": "ImagingStudy.accession",
              "equivalence": "relatedto",
              "comment": "Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`.\nSee discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type."
            },
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.identifier",
              "display": "ImagingStudy.identifier",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`.\nSee discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type."
            },
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "relatedto"
                }
              ],
              "code": "ImagingStudy.uid",
              "display": "ImagingStudy.uid",
              "equivalence": "relatedto",
              "comment": "Element `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.uid` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.accession` as `SourceIsBroaderThanTarget`.\nElement `ImagingStudy.identifier` is mapped to FHIR STU3 element `ImagingStudy.identifier` as `Equivalent`.\nSee discussion under [Imaging Study Implementation Notes](https://hl7.org/fhir/imagin.html#notes) for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type."
            }
          ]
        },
        {
          "code": "ImagingStudy.status",
          "display": "status",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.availability",
              "display": "ImagingStudy.availability",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.status` is mapped to FHIR STU3 element `ImagingStudy.availability` as `Equivalent`.\nUnknown does not represent \"other\" - one of the defined statuses must apply.  Unknown is used when the authoring system is not sure what the current status is."
            }
          ]
        },
        {
          "code": "ImagingStudy.modality",
          "display": "modality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.modalityList",
              "display": "ImagingStudy.modalityList",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.modality` is mapped to FHIR STU3 element `ImagingStudy.modalityList` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.subject",
          "display": "subject",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.patient",
              "display": "ImagingStudy.patient",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.subject` is mapped to FHIR STU3 element `ImagingStudy.patient` as `SourceIsBroaderThanTarget`.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4 element `ImagingStudy.subject` with unmapped reference targets: Device, Group.\nQA phantoms can be recorded with a Device; multiple subjects (such as mice) can be recorded with a Group."
            }
          ]
        },
        {
          "code": "ImagingStudy.encounter",
          "display": "encounter",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.context",
              "display": "ImagingStudy.context",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.encounter` is mapped to FHIR STU3 element `ImagingStudy.context` as `Equivalent`.\nThis will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission test)."
            }
          ]
        },
        {
          "code": "ImagingStudy.started",
          "display": "started",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.started",
              "display": "ImagingStudy.started",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.started` is mapped to FHIR STU3 element `ImagingStudy.started` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.basedOn",
          "display": "basedOn",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.basedOn",
              "display": "ImagingStudy.basedOn",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.basedOn` is mapped to FHIR STU3 element `ImagingStudy.basedOn` as `SourceIsBroaderThanTarget`.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4 element `ImagingStudy.basedOn` with unmapped reference targets: Appointment, AppointmentResponse, ServiceRequest, Task."
            }
          ]
        },
        {
          "code": "ImagingStudy.referrer",
          "display": "referrer",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.referrer",
              "display": "ImagingStudy.referrer",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.referrer` is mapped to FHIR STU3 element `ImagingStudy.referrer` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.referrer` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4 element `ImagingStudy.referrer` with unmapped reference targets: PractitionerRole."
            }
          ]
        },
        {
          "code": "ImagingStudy.interpreter",
          "display": "interpreter",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.interpreter",
              "display": "ImagingStudy.interpreter",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.interpreter` is mapped to FHIR STU3 element `ImagingStudy.interpreter` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.interpreter` do not cover the following types based on type expansion: display, identifier, reference, type.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR R4 element `ImagingStudy.interpreter` with unmapped reference targets: PractitionerRole."
            }
          ]
        },
        {
          "code": "ImagingStudy.endpoint",
          "display": "endpoint",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.endpoint",
              "display": "ImagingStudy.endpoint",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.endpoint` is mapped to FHIR STU3 element `ImagingStudy.endpoint` as `Equivalent`.\nTypical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG), formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances; or IHE Invoke Image Display (IID), which provides standard invocation of an imaging web viewer."
            }
          ]
        },
        {
          "code": "ImagingStudy.numberOfSeries",
          "display": "numberOfSeries",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.numberOfSeries",
              "display": "ImagingStudy.numberOfSeries",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.numberOfSeries` is mapped to FHIR STU3 element `ImagingStudy.numberOfSeries` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.numberOfInstances",
          "display": "numberOfInstances",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.numberOfInstances",
              "display": "ImagingStudy.numberOfInstances",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.numberOfInstances` is mapped to FHIR STU3 element `ImagingStudy.numberOfInstances` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.procedureReference",
          "display": "procedureReference",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.procedureReference",
              "display": "ImagingStudy.procedureReference",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.procedureReference` is mapped to FHIR STU3 element `ImagingStudy.procedureReference` as `SourceIsNarrowerThanTarget`."
            }
          ]
        },
        {
          "code": "ImagingStudy.procedureCode",
          "display": "procedureCode",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.procedureCode",
              "display": "ImagingStudy.procedureCode",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.procedureCode` is mapped to FHIR STU3 element `ImagingStudy.procedureCode` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.reasonCode",
          "display": "reasonCode",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.reason",
              "display": "ImagingStudy.reason",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.reasonCode` is mapped to FHIR STU3 element `ImagingStudy.reason` as `SourceIsBroaderThanTarget`."
            }
          ]
        },
        {
          "code": "ImagingStudy.description",
          "display": "description",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.description",
              "display": "ImagingStudy.description",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.description` is mapped to FHIR STU3 element `ImagingStudy.description` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series",
          "display": "series",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series",
              "display": "ImagingStudy.series",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series` is mapped to FHIR STU3 element `ImagingStudy.series` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.uid",
              "display": "ImagingStudy.series.uid",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.uid` is mapped to FHIR STU3 element `ImagingStudy.series.uid` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.uid` do not cover the following types: id.\nThe mappings for `ImagingStudy.series.uid` do not cover the following types based on type expansion: value.\nSee [DICOM PS3.3 C.7.3](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.7.3.html)."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.number",
          "display": "number",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.number",
              "display": "ImagingStudy.series.number",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.number` is mapped to FHIR STU3 element `ImagingStudy.series.number` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.modality",
          "display": "modality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.modality",
              "display": "ImagingStudy.series.modality",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.modality` is mapped to FHIR STU3 element `ImagingStudy.series.modality` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.description",
          "display": "description",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.description",
              "display": "ImagingStudy.series.description",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.description` is mapped to FHIR STU3 element `ImagingStudy.series.description` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.numberOfInstances",
          "display": "numberOfInstances",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.numberOfInstances",
              "display": "ImagingStudy.series.numberOfInstances",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.numberOfInstances` is mapped to FHIR STU3 element `ImagingStudy.series.numberOfInstances` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.endpoint",
          "display": "endpoint",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.endpoint",
              "display": "ImagingStudy.series.endpoint",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.endpoint` is mapped to FHIR STU3 element `ImagingStudy.series.endpoint` as `Equivalent`.\nTypical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; and DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.bodySite",
          "display": "bodySite",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.bodySite",
              "display": "ImagingStudy.series.bodySite",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.bodySite` is mapped to FHIR STU3 element `ImagingStudy.series.bodySite` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.laterality",
          "display": "laterality",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.laterality",
              "display": "ImagingStudy.series.laterality",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.laterality` is mapped to FHIR STU3 element `ImagingStudy.series.laterality` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.started",
          "display": "started",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.started",
              "display": "ImagingStudy.series.started",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.started` is mapped to FHIR STU3 element `ImagingStudy.series.started` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.performer",
          "display": "performer",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.performer",
              "display": "ImagingStudy.series.performer",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.performer` is mapped to FHIR STU3 element `ImagingStudy.series.performer` as `Equivalent`.\nIf the person who performed the series is not known, their Organization may be recorded. A patient, or related person, may be the performer, e.g. for patient-captured images."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance",
          "display": "instance",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.instance",
              "display": "ImagingStudy.series.instance",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.instance` is mapped to FHIR STU3 element `ImagingStudy.series.instance` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.instance.uid",
              "display": "ImagingStudy.series.instance.uid",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.instance.uid` is mapped to FHIR STU3 element `ImagingStudy.series.instance.uid` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.instance.uid` do not cover the following types: id.\nThe mappings for `ImagingStudy.series.instance.uid` do not cover the following types based on type expansion: value.\nSee  [DICOM PS3.3 C.12.1](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.12.html#sect_C.12.1)."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance.sopClass",
          "display": "sopClass",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "ImagingStudy.series.instance.sopClass",
              "display": "ImagingStudy.series.instance.sopClass",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.instance.sopClass` is mapped to FHIR STU3 element `ImagingStudy.series.instance.sopClass` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types: Coding.\nThe mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types based on type expansion: code, display, system, userSelected, version."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance.number",
          "display": "number",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.instance.number",
              "display": "ImagingStudy.series.instance.number",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.instance.number` is mapped to FHIR STU3 element `ImagingStudy.series.instance.number` as `Equivalent`."
            }
          ]
        },
        {
          "code": "ImagingStudy.series.instance.title",
          "display": "title",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "ImagingStudy.series.instance.title",
              "display": "ImagingStudy.series.instance.title",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.instance.title` is mapped to FHIR STU3 element `ImagingStudy.series.instance.title` as `Equivalent`.\nParticularly for post-acquisition analytic objects, such as SR, presentation states, value mapping, etc."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.location",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.location",
          "display": "location",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.location` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.location` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.reasonReference",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.reasonReference",
          "display": "reasonReference",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.reasonReference` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.reasonReference` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.note",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.note",
          "display": "note",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.note` has a context of ImagingStudy based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.note` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.series.uid",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.uid` is mapped to FHIR STU3 element `ImagingStudy.series.uid` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.uid` do not cover the following types: id.\nThe mappings for `ImagingStudy.series.uid` do not cover the following types based on type expansion: value.\nSee [DICOM PS3.3 C.7.3](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.7.3.html)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.series.specimen",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.specimen",
          "display": "specimen",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.specimen` has a context of ImagingStudy.series based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.series.specimen` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.series.performer.function",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.performer.function",
          "display": "function",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.performer.function` has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.series.performer.function` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.series.performer.actor",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.performer.actor",
          "display": "actor",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingStudy.series.performer.actor` has a context of ImagingStudy.series.performer based on following the parent source element upwards and mapping to `ImagingStudy`.\nElement `ImagingStudy.series.performer.actor` has no mapping targets in FHIR STU3. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.series.instance.uid",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.instance.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.instance.uid` is mapped to FHIR STU3 element `ImagingStudy.series.instance.uid` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.instance.uid` do not cover the following types: id.\nThe mappings for `ImagingStudy.series.instance.uid` do not cover the following types based on type expansion: value.\nSee  [DICOM PS3.3 C.12.1](http://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.12.html#sect_C.12.1)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingStudy",
      "sourceVersion": "4.0.1",
      "target": "http://hl7.org/fhir/4.0/StructureDefinition/extension-ImagingStudy.series.instance.sopClass",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingStudy.series.instance.sopClass",
          "display": "sopClass",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `ImagingStudy.series.instance.sopClass` is mapped to FHIR STU3 element `ImagingStudy.series.instance.sopClass` as `SourceIsBroaderThanTarget`.\nThe mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types: Coding.\nThe mappings for `ImagingStudy.series.instance.sopClass` do not cover the following types based on type expansion: code, display, system, userSelected, version."
            }
          ]
        }
      ]
    }
  ]
}