FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r3.r4b
Resource TypeValueSet
IdValueSet-R3-observation-interpretation-for-R4B.json
FHIR VersionR4B
Sourcehttp://hl7.org/fhir/uv/xver-r3.r4b/0.1.0/ValueSet-R3-observation-interpretation-for-R4B.html
URLhttp://hl7.org/fhir/uv/xver/ValueSet/R3-observation-interpretation-for-R4B
Version0.1.0
Statusactive
Date2026-03-17T21:02:03.8104715+00:00
NameR3ObservationInterpretationForR4B
TitleCross-version ValueSet STU3.Observation Interpretation Codes for use in FHIR R4B
Realmuv
Authorityhl7
DescriptionThis cross-version ValueSet represents content from http://hl7.org/fhir/ValueSet/observation-interpretation|3.0.2 for use in FHIR R4B that is appropriate for use but unavailable in `http://hl7.org/fhir/ValueSet/observation-interpretation|4.3.0`.
PurposeThis value set is part of the cross-version definitions generated to enable use of the value set `http://hl7.org/fhir/ValueSet/observation-interpretation|3.0.2` as defined in FHIR STU3 in FHIR R4B. The source value set is bound to the following FHIR STU3 elements: * `Observation.component.interpretation` as Extensible * `Observation.interpretation` as Extensible Across FHIR versions, the value set has been mapped as: * `http://hl7.org/fhir/ValueSet/observation-interpretation|3.0.2` * `http://hl7.org/fhir/ValueSet/observation-interpretation|4.0.1` * `http://hl7.org/fhir/ValueSet/observation-interpretation|4.3.0` Note that there are 31 concepts not included in this cross-version definition because they have valid representations. Following are the generation technical comments: One or more source concepts are either not mapped or broader than their targets, so the value set relationship is broadened. The source and target value sets have the same number of active concepts (39). All concepts in the comparison are listed as identical. The source and target value sets have the same number of active concepts (39).

Resources that use this resource

No resources found


Resources that this resource uses

CodeSystem
hl7.fhir.uv.xver-r2.r4b#0.1.00078v2-0078

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ValueSet R3-observation-interpretation-for-R4B

This value set expansion contains 8 concepts.

SystemVersionCodeDisplay
http://hl7.org/fhir/v2/00782.8.2  ACAnti-complementary substances present
http://hl7.org/fhir/v2/00782.8.2  HMHold for Medical Review
http://hl7.org/fhir/v2/00782.8.2  MSModerately susceptible. Indicates for microbiology susceptibilities only.
http://hl7.org/fhir/v2/00782.8.2  OBXInterpretation qualifiers in separate OBX segments
http://hl7.org/fhir/v2/00782.8.2  QCFQuality Control Failure
http://hl7.org/fhir/v2/00782.8.2  TOXCytotoxic substance present
http://hl7.org/fhir/v2/00782.8.2  VSVery susceptible. Indicates for microbiology susceptibilities only.
http://hl7.org/fhir/v2/00782.8.2  nullNo range defined, or normal ranges don't apply

Source1

{
  "resourceType": "ValueSet",
  "id": "R3-observation-interpretation-for-R4B",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 5
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "oo"
    },
    {
      "extension": [
        {
          "url": "packageId",
          "valueId": "hl7.fhir.uv.xver-r3.r4b"
        },
        {
          "url": "version",
          "valueString": "0.1.0"
        },
        {
          "url": "uri",
          "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r3.r4b"
        }
      ],
      "url": "http://hl7.org/fhir/StructureDefinition/package-source"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r3.r4b"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ValueSet/R3-observation-interpretation-for-R4B",
  "version": "0.1.0",
  "name": "R3ObservationInterpretationForR4B",
  "title": "Cross-version ValueSet STU3.Observation Interpretation Codes for use in FHIR R4B",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T21:02:03.8104715+00:00",
  "publisher": "Orders and Observations",
  "contact": [
    {
      "name": "Orders and Observations",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/orders"
        }
      ]
    }
  ],
  "description": "This cross-version ValueSet represents content from http://hl7.org/fhir/ValueSet/observation-interpretation|3.0.2 for use in FHIR R4B that is appropriate for use but unavailable in `http://hl7.org/fhir/ValueSet/observation-interpretation|4.3.0`.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "purpose": "This value set is part of the cross-version definitions generated to enable use of the\r\nvalue set `http://hl7.org/fhir/ValueSet/observation-interpretation|3.0.2` as defined in FHIR STU3\r\nin FHIR R4B.\r\n\r\nThe source value set is bound to the following FHIR STU3 elements:\r\n* `Observation.component.interpretation` as Extensible\n* `Observation.interpretation` as Extensible\r\n\r\nAcross FHIR versions, the value set has been mapped as:\r\n* `http://hl7.org/fhir/ValueSet/observation-interpretation|3.0.2`\n* `http://hl7.org/fhir/ValueSet/observation-interpretation|4.0.1`\n* `http://hl7.org/fhir/ValueSet/observation-interpretation|4.3.0`\r\n\r\nNote that there are 31 concepts not included in this cross-version definition because they have valid representations.\r\n\r\nFollowing are the generation technical comments:\r\nOne or more source concepts are either not mapped or broader than their targets, so the value set relationship is broadened.\nThe source and target value sets have the same number of active concepts (39).\nAll concepts in the comparison are listed as identical.\nThe source and target value sets have the same number of active concepts (39).",
  "compose": {
    "include": [
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "concept": [
          {
            "code": "AC",
            "display": "Anti-complementary substances present"
          },
          {
            "code": "HM",
            "display": "Hold for Medical Review"
          },
          {
            "code": "MS",
            "display": "Moderately susceptible. Indicates for microbiology susceptibilities only."
          },
          {
            "code": "OBX",
            "display": "Interpretation qualifiers in separate OBX segments"
          },
          {
            "code": "QCF",
            "display": "Quality Control Failure"
          },
          {
            "code": "TOX",
            "display": "Cytotoxic substance present"
          },
          {
            "code": "VS",
            "display": "Very susceptible. Indicates for microbiology susceptibilities only."
          },
          {
            "code": "null",
            "display": "No range defined, or normal ranges don't apply"
          }
        ]
      }
    ]
  },
  "expansion": {
    "timestamp": "2026-03-17T21:02:03.8104715+00:00",
    "contains": [
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "code": "AC",
        "display": "Anti-complementary substances present"
      },
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "code": "HM",
        "display": "Hold for Medical Review"
      },
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "code": "MS",
        "display": "Moderately susceptible. Indicates for microbiology susceptibilities only."
      },
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "code": "OBX",
        "display": "Interpretation qualifiers in separate OBX segments"
      },
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "code": "QCF",
        "display": "Quality Control Failure"
      },
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "code": "TOX",
        "display": "Cytotoxic substance present"
      },
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "code": "VS",
        "display": "Very susceptible. Indicates for microbiology susceptibilities only."
      },
      {
        "system": "http://hl7.org/fhir/v2/0078",
        "version": "2.8.2",
        "code": "null",
        "display": "No range defined, or normal ranges don't apply"
      }
    ]
  }
}