FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r2.r5
Resource TypeValueSet
IdValueSet-R2-investigation-sets-for-R5.json
FHIR VersionR5
Sourcehttp://hl7.org/fhir/uv/xver-r2.r5/0.1.0/ValueSet-R2-investigation-sets-for-R5.html
URLhttp://hl7.org/fhir/uv/xver/ValueSet/R2-investigation-sets-for-R5
Version0.1.0
Statusactive
Date2026-03-17T21:02:03.8104715+00:00
NameR2InvestigationSetsForR5
TitleCross-version ValueSet DSTU2.Condition/Diagnosis Certainty for use in FHIR R5
Realmuv
Authorityhl7
DescriptionThis cross-version ValueSet represents content from `http://hl7.org/fhir/ValueSet/investigation-sets|1.0.2` for use in FHIR R5.
PurposeThis value set is part of the cross-version definitions generated to enable use of the value set `http://hl7.org/fhir/ValueSet/investigation-sets|1.0.2` as defined in FHIR DSTU2 in FHIR R5. The source value set is bound to the following FHIR DSTU2 elements: * `ClinicalImpression.investigations.code` as Example Across FHIR versions, the value set has been mapped as: * `http://hl7.org/fhir/ValueSet/investigation-sets|1.0.2` * `http://hl7.org/fhir/ValueSet/investigation-sets|3.0.2` * `http://hl7.org/fhir/ValueSet/investigation-sets|4.0.1` * `http://hl7.org/fhir/ValueSet/investigation-sets|4.3.0` Note that all concepts are included in this cross-version definition because no concepts have compatible representations Following are the generation technical comments: All concepts in the comparison are listed as identical. The source value set has more active concepts (2) than the target (0), so the source is broader than the target. All concepts in the comparison are listed as identical. The source and target value sets have the same number of active concepts (0). All concepts in the comparison are listed as identical. The source and target value sets have the same number of active concepts (0). FHIR ValueSet `http://hl7.org/fhir/ValueSet/investigation-sets|1.0.2`, defined in FHIR DSTU2 does not have any mapping to FHIR R5

Resources that use this resource

StructureDefinition
hl7.fhir.uv.xver-r2.r5#0.1.0extension-ClinicalImpression.investigationsDSTU2: One or more sets of investigations (signs, symptions, etc.) (new)

Resources that this resource uses

CodeSystem
who.ddcc#currentsctSNOMED codes used in this IG

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ValueSet R2-investigation-sets-for-R5

This value set expansion contains 2 concepts.

SystemVersionCodeDisplay
http://snomed.info/sct1.0.2  160237006History/symptoms
http://snomed.info/sct1.0.2  271336007Examination / signs

Source1

{
  "resourceType": "ValueSet",
  "id": "R2-investigation-sets-for-R5",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    },
    {
      "extension": [
        {
          "url": "packageId",
          "valueId": "hl7.fhir.uv.xver-r2.r5"
        },
        {
          "url": "version",
          "valueString": "0.1.0"
        },
        {
          "url": "uri",
          "valueUri": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r5"
        }
      ],
      "url": "http://hl7.org/fhir/StructureDefinition/package-source"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r5"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r5"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ValueSet/R2-investigation-sets-for-R5",
  "version": "0.1.0",
  "name": "R2InvestigationSetsForR5",
  "title": "Cross-version ValueSet DSTU2.Condition/Diagnosis Certainty for use in FHIR R5",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T21:02:03.8104715+00:00",
  "publisher": "FHIR Infrastructure",
  "contact": [
    {
      "name": "FHIR Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "This cross-version ValueSet represents content from `http://hl7.org/fhir/ValueSet/investigation-sets|1.0.2` for use in FHIR R5.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "purpose": "This value set is part of the cross-version definitions generated to enable use of the\r\nvalue set `http://hl7.org/fhir/ValueSet/investigation-sets|1.0.2` as defined in FHIR DSTU2\r\nin FHIR R5.\r\n\r\nThe source value set is bound to the following FHIR DSTU2 elements:\r\n* `ClinicalImpression.investigations.code` as Example\r\n\r\nAcross FHIR versions, the value set has been mapped as:\r\n* `http://hl7.org/fhir/ValueSet/investigation-sets|1.0.2`\n* `http://hl7.org/fhir/ValueSet/investigation-sets|3.0.2`\n* `http://hl7.org/fhir/ValueSet/investigation-sets|4.0.1`\n* `http://hl7.org/fhir/ValueSet/investigation-sets|4.3.0`\r\n\r\nNote that all concepts are included in this cross-version definition because no concepts have compatible representations\r\n\r\nFollowing are the generation technical comments:\r\nAll concepts in the comparison are listed as identical.\nThe source value set has more active concepts (2) than the target (0), so the source is broader than the target.\nAll concepts in the comparison are listed as identical.\nThe source and target value sets have the same number of active concepts (0).\nAll concepts in the comparison are listed as identical.\nThe source and target value sets have the same number of active concepts (0).\nFHIR ValueSet `http://hl7.org/fhir/ValueSet/investigation-sets|1.0.2`, defined in FHIR DSTU2 does not have any mapping to FHIR R5",
  "compose": {
    "include": [
      {
        "system": "http://snomed.info/sct",
        "version": "1.0.2",
        "concept": [
          {
            "code": "160237006",
            "display": "History/symptoms"
          },
          {
            "code": "271336007",
            "display": "Examination / signs"
          }
        ]
      }
    ]
  },
  "expansion": {
    "timestamp": "2026-03-17T21:02:03.8104715+00:00",
    "contains": [
      {
        "system": "http://snomed.info/sct",
        "version": "1.0.2",
        "code": "160237006",
        "display": "History/symptoms"
      },
      {
        "system": "http://snomed.info/sct",
        "version": "1.0.2",
        "code": "271336007",
        "display": "Examination / signs"
      }
    ]
  }
}