FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r2.r4b
Resource TypeConceptMap
IdConceptMap-R2-ImagingObjectSelection-element-map-to-R4B.json
FHIR VersionR4B
Sourcehttp://hl7.org/fhir/uv/xver-r2.r4b/0.1.0/ConceptMap-R2-ImagingObjectSelection-element-map-to-R4B.html
URLhttp://hl7.org/fhir/uv/xver/ConceptMap/R2-ImagingObjectSelection-element-map-to-R4B
Version0.1.0
Statusactive
Date2026-03-17T16:04:54.784929-05:00
NameR2ImagingObjectSelectionElementMapToR4B
TitleCross-version mapping for FHIR DSTU2 ImagingObjectSelection to FHIR R4B Basic
Realmuv
Authorityhl7
DescriptionThis ConceptMap represents cross-version mappings for elements from a FHIR DSTU2 ImagingObjectSelection to FHIR R4B.

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-ImagingObjectSelection.authoringTimeDSTU2: Authoring time of the selection (new)
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-ImagingObjectSelection.descriptionDSTU2: Description text (new)
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-ImagingObjectSelection.patientDSTU2: Patient of the selected objects (new)
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-ImagingObjectSelection.studyDSTU2: Study identity of the selected instances (new)
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-ImagingObjectSelection.titleDSTU2: Reason for selection (new)
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-ImagingObjectSelection.uidDSTU2: Instance UID (new)

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap R2-ImagingObjectSelection-element-map-to-R4B

Mapping from http://hl7.org/fhir/1.0 to http://hl7.org/fhir/4.3


Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to Basicversion: 4.3.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.meta (meta)is equivalent toBasic.metaElement matches Basic element path `Basic.meta` (`Resource.meta`), use that element instead. Element `ImagingObjectSelection.meta` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.meta` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.implicitRules (implicitRules)is equivalent toBasic.implicitRulesElement matches Basic element path `Basic.implicitRules` (`Resource.implicitRules`), use that element instead. Element `ImagingObjectSelection.implicitRules` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.implicitRules` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element as much as possible.
ImagingObjectSelection.language (language)is equivalent toBasic.languageElement matches Basic element path `Basic.language` (`Resource.language`), use that element instead. Element `ImagingObjectSelection.language` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.language` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).
ImagingObjectSelection.text (text)is equivalent toBasic.textElement matches Basic element path `Basic.text` (`DomainResource.text`), use that element instead. Element `ImagingObjectSelection.text` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.text` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative.
ImagingObjectSelection.contained (contained)is equivalent toBasic.containedElement matches Basic element path `Basic.contained` (`DomainResource.contained`), use that element instead. Element `ImagingObjectSelection.contained` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.contained` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again.
ImagingObjectSelection.author (author)is equivalent toBasic.authorElement matches Basic element path `Basic.author` (`Basic.author`), use that element instead. Element `ImagingObjectSelection.author` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.author` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).

Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Instance UID (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.uid (uid)maps to wider conceptExtension (DSTU2: Instance UID (new))Element `ImagingObjectSelection.uid` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.uid` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).

Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Patient of the selected objects (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.patient (patient)maps to wider conceptExtension (DSTU2: Patient of the selected objects (new))Element `ImagingObjectSelection.patient` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.patient` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). SOP instances selected in the ImagingObjectSelection can be from different studies, but must be of the same patient.

Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Reason for selection (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.title (title)maps to wider conceptExtension (DSTU2: Reason for selection (new))Element `ImagingObjectSelection.title` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.title` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Coded concept of kind of the ImagingObjectSelection. Value set is defined in the DICOM standard Part 16, CID-7010.

Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Description text (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.description (description)maps to wider conceptExtension (DSTU2: Description text (new))Element `ImagingObjectSelection.description` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.description` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Free text narrative description of the ImagingObjectSelection.

Group 6 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Authoring time of the selection (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.authoringTime (authoringTime)maps to wider conceptExtension (DSTU2: Authoring time of the selection (new))Element `ImagingObjectSelection.authoringTime` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.authoringTime` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).

Group 7 Mapping from http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection|1.0.2 to DSTU2: Study identity of the selected instances (new)version: 0.1.0)

Source CodeRelationshipTarget CodeComment
ImagingObjectSelection.study (study)maps to wider conceptExtension (DSTU2: Study identity of the selected instances (new))Element `ImagingObjectSelection.study` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Study component represents the study level identity and locator information of the DICOM SOP instances in the selection. It is the top level identity of the hierachical identification of the instances.
ImagingObjectSelection.study.uid (uid)maps to wider conceptExtension.extension:uid (DSTU2: Study instance UID (new))Element `ImagingObjectSelection.study.uid` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension. Element `ImagingObjectSelection.study.uid` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.uid` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.study.url (url)maps to wider conceptExtension.extension:url (DSTU2: Retrieve study URL (new))Element `ImagingObjectSelection.study.url` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension. Element `ImagingObjectSelection.study.url` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.url` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Study level locator information is optional. If provided, this is the URL to retrieve the entire study with WADO-RS interaction, though only a subset of these are selected in the selection.
ImagingObjectSelection.study.imagingStudy (imagingStudy)maps to wider conceptExtension.extension:imagingStudy (DSTU2: Reference to ImagingStudy (new))Element `ImagingObjectSelection.study.imagingStudy` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension. Element `ImagingObjectSelection.study.imagingStudy` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.imagingStudy` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.study.series (series)maps to wider conceptExtension.extension:series (DSTU2: Series identity of the selected instances (new))Element `ImagingObjectSelection.study.series` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension. Element `ImagingObjectSelection.study.series` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Series component represents the series level identity and locator information of the DICOM SOP instances in the selection.
ImagingObjectSelection.study.series.uid (uid)maps to wider conceptExtension.extension:series.extension:uid (DSTU2: Series instance UID (new))Element `ImagingObjectSelection.study.series.uid` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension. Element `ImagingObjectSelection.study.series.uid` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.uid` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.study.series.url (url)maps to wider conceptExtension.extension:series.extension:url (DSTU2: Retrieve series URL (new))Element `ImagingObjectSelection.study.series.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension. Element `ImagingObjectSelection.study.series.url` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.url` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Series level locator information is optional. If provided, this is the URL to retrieve the entire series with WADO-RS interaction, though only a subset of these are selected in the selection.
ImagingObjectSelection.study.series.instance (instance)maps to wider conceptExtension.extension:series.extension:instance (DSTU2: The selected instance (new))Element `ImagingObjectSelection.study.series.instance` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). SOP Instance component identify the instance selected, along with the study and series identities to form the DICOM identity hierachy.
ImagingObjectSelection.study.series.instance.sopClass (sopClass)maps to wider conceptExtension.extension:series.extension:instance.extension:sopClass (DSTU2: SOP class UID of instance (new))Element `ImagingObjectSelection.study.series.instance.sopClass` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.sopClass` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.sopClass` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). SOP class UID identifies the type of the selected instances, e.g. CT image, Gray scale softcopy presentation state, ECG waveform, etc.
ImagingObjectSelection.study.series.instance.uid (uid)maps to wider conceptExtension.extension:series.extension:instance.extension:uid (DSTU2: Selected instance UID (new))Element `ImagingObjectSelection.study.series.instance.uid` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.uid` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.uid` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). SOP instance UID identifies the instance.
ImagingObjectSelection.study.series.instance.url (url)maps to wider conceptExtension.extension:series.extension:instance.extension:url (DSTU2: Retrieve instance URL (new))Element `ImagingObjectSelection.study.series.instance.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.url` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.url` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Instance level locator information is required.
ImagingObjectSelection.study.series.instance.frames (frames)maps to wider conceptExtension.extension:series.extension:instance.extension:frames (DSTU2: The frame set (new))Element `ImagingObjectSelection.study.series.instance.frames` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.frames` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.frames` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). This component may be used if the referenced image SOP Instance is a multi-frame image.
ImagingObjectSelection.study.series.instance.frames.frameNumbers (frameNumbers)maps to wider conceptExtension.extension:series.extension:instance.extension:frames.extension:frameNumbers (DSTU2: Frame numbers (new))Element `ImagingObjectSelection.study.series.instance.frames.frameNumbers` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance.frames` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.frames.frameNumbers` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.frames.frameNumbers` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).
ImagingObjectSelection.study.series.instance.frames.url (url)maps to wider conceptExtension.extension:series.extension:instance.extension:frames.extension:url (DSTU2: Retrieve frame URL (new))Element `ImagingObjectSelection.study.series.instance.frames.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance.frames` requires a cross-version extension. Element `ImagingObjectSelection.study.series.instance.frames.url` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped. Element `ImagingObjectSelection.study.series.instance.frames.url` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element). Frame level locator information is required.

Source1

{
  "resourceType": "ConceptMap",
  "id": "R2-ImagingObjectSelection-element-map-to-R4B",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r4b"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r4b"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ConceptMap/R2-ImagingObjectSelection-element-map-to-R4B",
  "version": "0.1.0",
  "name": "R2ImagingObjectSelectionElementMapToR4B",
  "title": "Cross-version mapping for FHIR DSTU2 ImagingObjectSelection to FHIR R4B Basic",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T16:04:54.784929-05:00",
  "contact": [
    {
      "name": "FHIR Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "This ConceptMap represents cross-version mappings for elements from a FHIR DSTU2 ImagingObjectSelection to FHIR R4B.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "sourceCanonical": "http://hl7.org/fhir/1.0",
  "targetUri": "http://hl7.org/fhir/4.3",
  "group": [
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/StructureDefinition/Basic",
      "targetVersion": "4.3.0",
      "element": [
        {
          "code": "ImagingObjectSelection.meta",
          "display": "meta",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.meta",
              "display": "Basic.meta",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.meta` (`Resource.meta`), use that element instead.\nElement `ImagingObjectSelection.meta` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.meta` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element)."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.implicitRules",
          "display": "implicitRules",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.implicitRules",
              "display": "Basic.implicitRules",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.implicitRules` (`Resource.implicitRules`), use that element instead.\nElement `ImagingObjectSelection.implicitRules` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.implicitRules` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element as much as possible."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.language",
          "display": "language",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.language",
              "display": "Basic.language",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.language` (`Resource.language`), use that element instead.\nElement `ImagingObjectSelection.language` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.language` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource  Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.text",
          "display": "text",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.text",
              "display": "Basic.text",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.text` (`DomainResource.text`), use that element instead.\nElement `ImagingObjectSelection.text` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.text` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.contained",
          "display": "contained",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.contained",
              "display": "Basic.contained",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.contained` (`DomainResource.contained`), use that element instead.\nElement `ImagingObjectSelection.contained` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.contained` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.author",
          "display": "author",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "equivalent"
                }
              ],
              "code": "Basic.author",
              "display": "Basic.author",
              "equivalence": "equivalent",
              "comment": "Element matches Basic element path `Basic.author` (`Basic.author`), use that element instead.\nElement `ImagingObjectSelection.author` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.author` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ImagingObjectSelection.uid",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingObjectSelection.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.uid` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.uid` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ImagingObjectSelection.patient",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingObjectSelection.patient",
          "display": "patient",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.patient` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.patient` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nSOP instances selected in the ImagingObjectSelection can be from different studies, but must be of the same patient."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ImagingObjectSelection.title",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingObjectSelection.title",
          "display": "title",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.title` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.title` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nCoded concept of kind of the ImagingObjectSelection. Value set is defined in the DICOM standard Part 16, CID-7010."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ImagingObjectSelection.description",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingObjectSelection.description",
          "display": "description",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.description` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.description` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nFree text narrative description of the ImagingObjectSelection."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ImagingObjectSelection.authoringTime",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingObjectSelection.authoringTime",
          "display": "authoringTime",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.authoringTime` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.authoringTime` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element)."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/ImagingObjectSelection",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ImagingObjectSelection.study",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "ImagingObjectSelection.study",
          "display": "study",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nStudy component represents the study level identity and locator information of the DICOM SOP instances in the selection. It is the top level identity of the hierachical identification of the instances."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:uid",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.uid` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension.\nElement `ImagingObjectSelection.study.uid` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.uid` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element)."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.url",
          "display": "url",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:url",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.url` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension.\nElement `ImagingObjectSelection.study.url` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.url` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nStudy level locator information is optional. If provided, this is the URL to retrieve the entire study with WADO-RS interaction, though only a subset of these are selected in the selection."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.imagingStudy",
          "display": "imagingStudy",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:imagingStudy",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.imagingStudy` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension.\nElement `ImagingObjectSelection.study.imagingStudy` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.imagingStudy` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element)."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series",
          "display": "series",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series` is part of an existing definition because parent element `ImagingObjectSelection.study` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nSeries component represents the series level identity and locator information of the DICOM SOP instances in the selection."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:uid",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.uid` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.uid` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.uid` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element)."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.url",
          "display": "url",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:url",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.url` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.url` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nSeries level locator information is optional. If provided, this is the URL to retrieve the entire series with WADO-RS interaction, though only a subset of these are selected in the selection."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.instance",
          "display": "instance",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:instance",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.instance` is part of an existing definition because parent element `ImagingObjectSelection.study.series` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.instance` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.instance` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nSOP Instance component identify the instance selected, along with the study and series identities to form the DICOM identity hierachy."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.instance.sopClass",
          "display": "sopClass",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:instance.extension:sopClass",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.instance.sopClass` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.instance.sopClass` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.instance.sopClass` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nSOP class UID identifies the type of the selected instances, e.g. CT image, Gray scale softcopy presentation state, ECG waveform, etc."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.instance.uid",
          "display": "uid",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:instance.extension:uid",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.instance.uid` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.instance.uid` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.instance.uid` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nSOP instance UID identifies the instance."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.instance.url",
          "display": "url",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:instance.extension:url",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.instance.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.instance.url` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.instance.url` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nInstance level locator information is required."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.instance.frames",
          "display": "frames",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:instance.extension:frames",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.instance.frames` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.instance.frames` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.instance.frames` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nThis component may be used if the referenced image SOP Instance is a multi-frame image."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.instance.frames.frameNumbers",
          "display": "frameNumbers",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:instance.extension:frames.extension:frameNumbers",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.instance.frames.frameNumbers` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance.frames` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.instance.frames.frameNumbers` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.instance.frames.frameNumbers` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element)."
            }
          ]
        },
        {
          "code": "ImagingObjectSelection.study.series.instance.frames.url",
          "display": "url",
          "target": [
            {
              "modifierExtension": [
                {
                  "url": "http://hl7.org/fhir/1.0/StructureDefinition/extension-ConceptMap.element.target.equivalence",
                  "valueCode": "wider"
                }
              ],
              "code": "Extension.extension:series.extension:instance.extension:frames.extension:url",
              "equivalence": "wider",
              "comment": "Element `ImagingObjectSelection.study.series.instance.frames.url` is part of an existing definition because parent element `ImagingObjectSelection.study.series.instance.frames` requires a cross-version extension.\nElement `ImagingObjectSelection.study.series.instance.frames.url` is not mapped to FHIR R4B, since FHIR DSTU2 `ImagingObjectSelection` is not mapped.\nElement `ImagingObjectSelection.study.series.instance.frames.url` has no mapping targets in FHIR R4B. Typically, this is because the element has been added (is a new element).\nFrame level locator information is required."
            }
          ]
        }
      ]
    }
  ]
}