FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.xver-r2.r4
Resource TypeConceptMap
IdConceptMap-R2-DeviceMetric-element-map-to-R4.json
FHIR VersionR4
Sourcehttp://hl7.org/fhir/uv/xver-r2.r4/0.1.0/ConceptMap-R2-DeviceMetric-element-map-to-R4.html
URLhttp://hl7.org/fhir/uv/xver/ConceptMap/R2-DeviceMetric-element-map-to-R4
Version0.1.0
Statusactive
Date2026-03-17T16:04:02.4644874-05:00
NameR2DeviceMetricElementMapToR4
TitleCross-version mapping for FHIR DSTU2 DeviceMetric to FHIR R4 DeviceMetric
Realmuv
Authorityhl7
DescriptionThis ConceptMap represents cross-version mappings for elements from a FHIR DSTU2 DeviceMetric to FHIR R4.

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-DeviceMetric.identifierDSTU2: Unique identifier of this DeviceMetric additional types
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-DeviceMetric.measurementPeriodDSTU2: measurementPeriod additional types
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-DeviceMetric.metaDSTU2: meta additional types
hl7.fhir.uv.xver-r2.r4b#0.1.0extension-DeviceMetric.textDSTU2: text additional types

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap R2-DeviceMetric-element-map-to-R4

Mapping from http://hl7.org/fhir/1.0 to http://hl7.org/fhir/4.0


Group 1 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|1.0.2 to DeviceMetricversion: 4.0.1)

Source CodeRelationshipTarget CodeComment
DeviceMetric.meta (meta)maps to wider conceptDeviceMetric.metaElement `DeviceMetric.meta` is mapped to FHIR R4 element `DeviceMetric.meta` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.meta` do not cover the following types: Meta. The mappings for `DeviceMetric.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, tag, versionId.
DeviceMetric.implicitRules (implicitRules)is equivalent toDeviceMetric.implicitRulesElement `DeviceMetric.implicitRules` is mapped to FHIR R4 element `DeviceMetric.implicitRules` as `Equivalent`. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element as much as possible.
DeviceMetric.language (language)is equivalent toDeviceMetric.languageElement `DeviceMetric.language` is mapped to FHIR R4 element `DeviceMetric.language` as `Equivalent`. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute).
DeviceMetric.text (text)maps to wider conceptDeviceMetric.textElement `DeviceMetric.text` is mapped to FHIR R4 element `DeviceMetric.text` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.text` do not cover the following types: Narrative. The mappings for `DeviceMetric.text` do not cover the following types based on type expansion: div, status. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative.
DeviceMetric.contained (contained)is equivalent toDeviceMetric.containedElement `DeviceMetric.contained` is mapped to FHIR R4 element `DeviceMetric.contained` as `SourceIsBroaderThanTarget`. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again.
DeviceMetric.type (type)is equivalent toDeviceMetric.typeElement `DeviceMetric.type` is mapped to FHIR R4 element `DeviceMetric.type` as `Equivalent`. DeviceMetric.type can be referred to either GDMN (nomenclature system supported by FDA Global UDI Database) or preferable RTMMS coding system.
DeviceMetric.identifier (identifier)maps to wider conceptDeviceMetric.identifierElement `DeviceMetric.identifier` is mapped to FHIR R4 element `DeviceMetric.identifier` as `RelatedTo`. The mappings for `DeviceMetric.identifier` do not cover the following types: Identifier. The mappings for `DeviceMetric.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value.
DeviceMetric.unit (unit)is equivalent toDeviceMetric.unitElement `DeviceMetric.unit` is mapped to FHIR R4 element `DeviceMetric.unit` as `Equivalent`. DeviceMetric.unit can be referred to either UCUM or preferable RTMMS coding system.
DeviceMetric.source (source)maps to wider conceptDeviceMetric.sourceElement `DeviceMetric.source` is mapped to FHIR R4 element `DeviceMetric.source` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.source` do not cover the following types based on type expansion: display, reference. The standard extension `alternate-reference` has been mapped as the representation of FHIR DSTU2 element `DeviceMetric.source` with unmapped reference targets: Device.
DeviceMetric.parent (parent)maps to wider conceptDeviceMetric.parentElement `DeviceMetric.parent` is mapped to FHIR R4 element `DeviceMetric.parent` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.parent` do not cover the following types based on type expansion: display, reference. The standard extension `alternate-reference` has been mapped as the representation of FHIR DSTU2 element `DeviceMetric.parent` with unmapped reference targets: DeviceComponent.
DeviceMetric.operationalStatus (operationalStatus)is equivalent toDeviceMetric.operationalStatusElement `DeviceMetric.operationalStatus` is mapped to FHIR R4 element `DeviceMetric.operationalStatus` as `SourceIsNarrowerThanTarget`. The mappings for `DeviceMetric.operationalStatus` do not allow expression of the necessary codes, per the bindings on the source and target.
DeviceMetric.color (color)is equivalent toDeviceMetric.colorElement `DeviceMetric.color` is mapped to FHIR R4 element `DeviceMetric.color` as `Equivalent`.
DeviceMetric.category (category)is equivalent toDeviceMetric.categoryElement `DeviceMetric.category` is mapped to FHIR R4 element `DeviceMetric.category` as `Equivalent`.
DeviceMetric.measurementPeriod (measurementPeriod)maps to wider conceptDeviceMetric.measurementPeriodElement `DeviceMetric.measurementPeriod` is mapped to FHIR R4 element `DeviceMetric.measurementPeriod` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.measurementPeriod` do not cover the following types: Timing. The mappings for `DeviceMetric.measurementPeriod` do not cover the following types based on type expansion: bounds[x], code, count, duration, durationMax, durationUnits, event, frequency, frequencyMax, period, periodMax, periodUnits, repeat, when.
DeviceMetric.calibration (calibration)maps to wider conceptDeviceMetric.calibrationElement `DeviceMetric.calibration` is mapped to FHIR R4 element `DeviceMetric.calibration` as `Equivalent`.
DeviceMetric.calibration.type (type)is equivalent toDeviceMetric.calibration.typeElement `DeviceMetric.calibration.type` is mapped to FHIR R4 element `DeviceMetric.calibration.type` as `Equivalent`.
DeviceMetric.calibration.state (state)is equivalent toDeviceMetric.calibration.stateElement `DeviceMetric.calibration.state` is mapped to FHIR R4 element `DeviceMetric.calibration.state` as `Equivalent`.
DeviceMetric.calibration.time (time)is equivalent toDeviceMetric.calibration.timeElement `DeviceMetric.calibration.time` is mapped to FHIR R4 element `DeviceMetric.calibration.time` as `Equivalent`.

Group 2 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|1.0.2 to DSTU2: meta additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.meta (meta)is equivalent toExtension (DSTU2: meta additional types)Element `DeviceMetric.meta` is mapped to FHIR R4 element `DeviceMetric.meta` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.meta` do not cover the following types: Meta. The mappings for `DeviceMetric.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, tag, versionId.

Group 3 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|1.0.2 to DSTU2: text additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.text (text)is equivalent toExtension (DSTU2: text additional types)Element `DeviceMetric.text` is mapped to FHIR R4 element `DeviceMetric.text` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.text` do not cover the following types: Narrative. The mappings for `DeviceMetric.text` do not cover the following types based on type expansion: div, status. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative.

Group 4 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|1.0.2 to DSTU2: Unique identifier of this DeviceMetric additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.identifier (identifier)is equivalent toExtension (DSTU2: Unique identifier of this DeviceMetric additional types)Element `DeviceMetric.identifier` is mapped to FHIR R4 element `DeviceMetric.identifier` as `RelatedTo`. The mappings for `DeviceMetric.identifier` do not cover the following types: Identifier. The mappings for `DeviceMetric.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value.

Group 5 Mapping from http://hl7.org/fhir/StructureDefinition/DeviceMetric|1.0.2 to DSTU2: measurementPeriod additional typesversion: 0.1.0)

Source CodeRelationshipTarget CodeComment
DeviceMetric.measurementPeriod (measurementPeriod)is equivalent toExtension (DSTU2: measurementPeriod additional types)Element `DeviceMetric.measurementPeriod` is mapped to FHIR R4 element `DeviceMetric.measurementPeriod` as `SourceIsBroaderThanTarget`. The mappings for `DeviceMetric.measurementPeriod` do not cover the following types: Timing. The mappings for `DeviceMetric.measurementPeriod` do not cover the following types based on type expansion: bounds[x], code, count, duration, durationMax, durationUnits, event, frequency, frequencyMax, period, periodMax, periodUnits, repeat, when.

Source1

{
  "resourceType": "ConceptMap",
  "id": "R2-DeviceMetric-element-map-to-R4",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 0,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r4"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/xver/ImplementationGuide/hl7.fhir.uv.xver-r2.r4"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/xver/ConceptMap/R2-DeviceMetric-element-map-to-R4",
  "version": "0.1.0",
  "name": "R2DeviceMetricElementMapToR4",
  "title": "Cross-version mapping for FHIR DSTU2 DeviceMetric to FHIR R4 DeviceMetric",
  "status": "active",
  "experimental": false,
  "date": "2026-03-17T16:04:02.4644874-05:00",
  "contact": [
    {
      "name": "FHIR Infrastructure",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "This ConceptMap represents cross-version mappings for elements from a FHIR DSTU2 DeviceMetric to FHIR R4.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "sourceCanonical": "http://hl7.org/fhir/1.0",
  "targetUri": "http://hl7.org/fhir/4.0",
  "group": [
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "targetVersion": "4.0.1",
      "element": [
        {
          "code": "DeviceMetric.meta",
          "display": "meta",
          "target": [
            {
              "code": "DeviceMetric.meta",
              "display": "DeviceMetric.meta",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.meta` is mapped to FHIR R4 element `DeviceMetric.meta` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.meta` do not cover the following types: Meta.\nThe mappings for `DeviceMetric.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, tag, versionId."
            }
          ]
        },
        {
          "code": "DeviceMetric.implicitRules",
          "display": "implicitRules",
          "target": [
            {
              "code": "DeviceMetric.implicitRules",
              "display": "DeviceMetric.implicitRules",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.implicitRules` is mapped to FHIR R4 element `DeviceMetric.implicitRules` as `Equivalent`.\nAsserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element as much as possible."
            }
          ]
        },
        {
          "code": "DeviceMetric.language",
          "display": "language",
          "target": [
            {
              "code": "DeviceMetric.language",
              "display": "DeviceMetric.language",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.language` is mapped to FHIR R4 element `DeviceMetric.language` as `Equivalent`.\nLanguage is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies  to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource  Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute)."
            }
          ]
        },
        {
          "code": "DeviceMetric.text",
          "display": "text",
          "target": [
            {
              "code": "DeviceMetric.text",
              "display": "DeviceMetric.text",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.text` is mapped to FHIR R4 element `DeviceMetric.text` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.text` do not cover the following types: Narrative.\nThe mappings for `DeviceMetric.text` do not cover the following types based on type expansion: div, status.\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative."
            }
          ]
        },
        {
          "code": "DeviceMetric.contained",
          "display": "contained",
          "target": [
            {
              "code": "DeviceMetric.contained",
              "display": "DeviceMetric.contained",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.contained` is mapped to FHIR R4 element `DeviceMetric.contained` as `SourceIsBroaderThanTarget`.\nThis should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again."
            }
          ]
        },
        {
          "code": "DeviceMetric.type",
          "display": "type",
          "target": [
            {
              "code": "DeviceMetric.type",
              "display": "DeviceMetric.type",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.type` is mapped to FHIR R4 element `DeviceMetric.type` as `Equivalent`.\nDeviceMetric.type can be referred to either GDMN (nomenclature system supported by FDA Global UDI Database) or preferable RTMMS coding system."
            }
          ]
        },
        {
          "code": "DeviceMetric.identifier",
          "display": "identifier",
          "target": [
            {
              "code": "DeviceMetric.identifier",
              "display": "DeviceMetric.identifier",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.identifier` is mapped to FHIR R4 element `DeviceMetric.identifier` as `RelatedTo`.\nThe mappings for `DeviceMetric.identifier` do not cover the following types: Identifier.\nThe mappings for `DeviceMetric.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value."
            }
          ]
        },
        {
          "code": "DeviceMetric.unit",
          "display": "unit",
          "target": [
            {
              "code": "DeviceMetric.unit",
              "display": "DeviceMetric.unit",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.unit` is mapped to FHIR R4 element `DeviceMetric.unit` as `Equivalent`.\nDeviceMetric.unit can be referred to either UCUM or preferable RTMMS coding system."
            }
          ]
        },
        {
          "code": "DeviceMetric.source",
          "display": "source",
          "target": [
            {
              "code": "DeviceMetric.source",
              "display": "DeviceMetric.source",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.source` is mapped to FHIR R4 element `DeviceMetric.source` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.source` do not cover the following types based on type expansion: display, reference.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR DSTU2 element `DeviceMetric.source` with unmapped reference targets: Device."
            }
          ]
        },
        {
          "code": "DeviceMetric.parent",
          "display": "parent",
          "target": [
            {
              "code": "DeviceMetric.parent",
              "display": "DeviceMetric.parent",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.parent` is mapped to FHIR R4 element `DeviceMetric.parent` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.parent` do not cover the following types based on type expansion: display, reference.\nThe standard extension `alternate-reference` has been mapped as the representation of FHIR DSTU2 element `DeviceMetric.parent` with unmapped reference targets: DeviceComponent."
            }
          ]
        },
        {
          "code": "DeviceMetric.operationalStatus",
          "display": "operationalStatus",
          "target": [
            {
              "code": "DeviceMetric.operationalStatus",
              "display": "DeviceMetric.operationalStatus",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.operationalStatus` is mapped to FHIR R4 element `DeviceMetric.operationalStatus` as `SourceIsNarrowerThanTarget`.\nThe mappings for `DeviceMetric.operationalStatus` do not allow expression of the necessary codes, per the bindings on the source and target."
            }
          ]
        },
        {
          "code": "DeviceMetric.color",
          "display": "color",
          "target": [
            {
              "code": "DeviceMetric.color",
              "display": "DeviceMetric.color",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.color` is mapped to FHIR R4 element `DeviceMetric.color` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.category",
          "display": "category",
          "target": [
            {
              "code": "DeviceMetric.category",
              "display": "DeviceMetric.category",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.category` is mapped to FHIR R4 element `DeviceMetric.category` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.measurementPeriod",
          "display": "measurementPeriod",
          "target": [
            {
              "code": "DeviceMetric.measurementPeriod",
              "display": "DeviceMetric.measurementPeriod",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.measurementPeriod` is mapped to FHIR R4 element `DeviceMetric.measurementPeriod` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.measurementPeriod` do not cover the following types: Timing.\nThe mappings for `DeviceMetric.measurementPeriod` do not cover the following types based on type expansion: bounds[x], code, count, duration, durationMax, durationUnits, event, frequency, frequencyMax, period, periodMax, periodUnits, repeat, when."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration",
          "display": "calibration",
          "target": [
            {
              "code": "DeviceMetric.calibration",
              "display": "DeviceMetric.calibration",
              "equivalence": "wider",
              "comment": "Element `DeviceMetric.calibration` is mapped to FHIR R4 element `DeviceMetric.calibration` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.type",
          "display": "type",
          "target": [
            {
              "code": "DeviceMetric.calibration.type",
              "display": "DeviceMetric.calibration.type",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.type` is mapped to FHIR R4 element `DeviceMetric.calibration.type` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.state",
          "display": "state",
          "target": [
            {
              "code": "DeviceMetric.calibration.state",
              "display": "DeviceMetric.calibration.state",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.state` is mapped to FHIR R4 element `DeviceMetric.calibration.state` as `Equivalent`."
            }
          ]
        },
        {
          "code": "DeviceMetric.calibration.time",
          "display": "time",
          "target": [
            {
              "code": "DeviceMetric.calibration.time",
              "display": "DeviceMetric.calibration.time",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.calibration.time` is mapped to FHIR R4 element `DeviceMetric.calibration.time` as `Equivalent`."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceMetric.meta",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.meta",
          "display": "meta",
          "target": [
            {
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.meta` is mapped to FHIR R4 element `DeviceMetric.meta` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.meta` do not cover the following types: Meta.\nThe mappings for `DeviceMetric.meta` do not cover the following types based on type expansion: lastUpdated, profile, security, tag, versionId."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceMetric.text",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.text",
          "display": "text",
          "target": [
            {
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.text` is mapped to FHIR R4 element `DeviceMetric.text` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.text` do not cover the following types: Narrative.\nThe mappings for `DeviceMetric.text` do not cover the following types based on type expansion: div, status.\nContained resources do not have narrative. Resources that are not contained SHOULD have a narrative."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceMetric.identifier",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.identifier",
          "display": "identifier",
          "target": [
            {
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.identifier` is mapped to FHIR R4 element `DeviceMetric.identifier` as `RelatedTo`.\nThe mappings for `DeviceMetric.identifier` do not cover the following types: Identifier.\nThe mappings for `DeviceMetric.identifier` do not cover the following types based on type expansion: assigner, period, system, type, use, value."
            }
          ]
        }
      ]
    },
    {
      "source": "http://hl7.org/fhir/StructureDefinition/DeviceMetric",
      "sourceVersion": "1.0.2",
      "target": "http://hl7.org/fhir/1.0/StructureDefinition/extension-DeviceMetric.measurementPeriod",
      "targetVersion": "0.1.0",
      "element": [
        {
          "code": "DeviceMetric.measurementPeriod",
          "display": "measurementPeriod",
          "target": [
            {
              "code": "Extension",
              "equivalence": "equivalent",
              "comment": "Element `DeviceMetric.measurementPeriod` is mapped to FHIR R4 element `DeviceMetric.measurementPeriod` as `SourceIsBroaderThanTarget`.\nThe mappings for `DeviceMetric.measurementPeriod` do not cover the following types: Timing.\nThe mappings for `DeviceMetric.measurementPeriod` do not cover the following types based on type expansion: bounds[x], code, count, duration, durationMax, durationUnits, event, frequency, frequencyMax, period, periodMax, periodUnits, repeat, when."
            }
          ]
        }
      ]
    }
  ]
}