Package | hl7.fhir.uv.v2mappings |
Type | ConceptMap |
Id | segment-prt-to-device |
FHIR Version | R4 |
Source | http://hl7.org/fhir/uv/v2mappings/https://build.fhir.org/ig/HL7/v2-to-fhir/ConceptMap-segment-prt-to-device.html |
URL | http://hl7.org/fhir/uv/v2mappings/ConceptMap/segment-prt-to-device |
Version | 1.0.0 |
Status | active |
Date | 2025-07-22 |
Name | SegmentPRTToDevice |
Title | Segment PRT to Device Map |
Realm | uv |
Authority | hl7 |
Description | This ConceptMap represents a mapping from the HL7 V2 Segment PRT to the FHIR Device Resource. |
Copyright | Copyright (c) 2025, HL7 International, Inc., All Rights Reserved. |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap segment-prt-to-device
Mapping from (not specified) to (not specified)
Group 1 Mapping from unspecified code system
to unspecified code system
Source Concept Details | Relationship | Target Concept Details | |||
Codes from | NarrativeCondition | Codes from | |||
PRT-10 | Device | If it represents a HRF or AIDC | is equivalent to | udiCarrier[1] | udiCarrier[1] |
PRT-10 | Device | If not an HRF or AIDC | is equivalent to | identifier | identifier |
PRT-16 | UDI Device Identifier | is equivalent to | udiCarrier[2] | udiCarrier[2] | |
PRT-17 | Device Manufacture Date | is equivalent to | manufactureDate | manufactureDate | |
PRT-18 | Device Expiry Date | is equivalent to | expirationDate | expirationDate | |
PRT-19 | Device Lot Number | is equivalent to | lotNumber | lotNumber | |
PRT-20 | Device Serial Number | is equivalent to | serialNumber | serialNumber | |
PRT-21 | Device Donation Identification | is equivalent to | distinctIdentifier | distinctIdentifier | |
PRT-22 | Device Type | is equivalent to | type | type |
{ "resourceType": "ConceptMap", "id": "segment-prt-to-device", "text": { "status": "generated", "div": "<!-- snip (see above) -->" }, "extension": [ { "extension": [ { "url": "type", "valueCode": "derived-from" }, { "url": "label", "valueString": "Segment PRT to Device.fsh" }, { "url": "url", "valueUri": "https://docs.google.com/spreadsheets/d/1kApBsX909N_5B--utrkPcLtEvI9m5We5GyRDk0dH1sU/edit#gid=0" } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/RelatedArtifact" }, { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode": "oo" }, { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status", "valueCode": "informative", "_valueCode": { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom", "valueCanonical": "http://hl7.org/fhir/uv/v2mappings/ImplementationGuide/hl7.fhir.uv.v2mappings" } ] } } ], "url": "http://hl7.org/fhir/uv/v2mappings/ConceptMap/segment-prt-to-device", "version": "1.0.0", "name": "SegmentPRTToDevice", "title": "Segment PRT to Device Map", "status": "active", "experimental": true, "date": "2025-07-22", "publisher": "HL7 International / Orders and Observations", "contact": [ { "name": "HL7 Orders and Observations Workgroup", "telecom": [ { "system": "url", "value": "http://www.hl7.org/Special/committees/orders" } ] } ], "description": "This ConceptMap represents a mapping from the HL7 V2 Segment PRT to the FHIR Device Resource.", "jurisdiction": [ { "coding": [ { "system": "http://unstats.un.org/unsd/methods/m49/m49.htm", "code": "001" } ] } ], "copyright": "Copyright (c) 2025, HL7 International, Inc., All Rights Reserved.", "group": [ { "element": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "EI" }, { "url": "cardinalityMin", "valueInteger": -1 }, { "url": "cardinalityMax", "valueInteger": -1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-10", "display": "Device", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "BackboneElement" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": -1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "udiCarrier[1]", "display": "udiCarrier[1]", "equivalence": "equivalent", "dependsOn": [ { "property": "Narrative-Condition", "value": "If it represents a HRF or AIDC" } ] } ] }, { "extension": [ { "extension": [ { "url": "type", "valueCode": "EI" }, { "url": "cardinalityMin", "valueInteger": -1 }, { "url": "cardinalityMax", "valueInteger": -1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-10", "display": "Device", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "Identifier" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": -1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "identifier", "display": "identifier", "equivalence": "equivalent", "dependsOn": [ { "property": "Narrative-Condition", "value": "If not an HRF or AIDC" } ] } ] }, { "extension": [ { "extension": [ { "url": "type", "valueCode": "EI" }, { "url": "cardinalityMin", "valueInteger": 1 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-16", "display": "UDI Device Identifier", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "BackboneElement" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": -1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "udiCarrier[2]", "display": "udiCarrier[2]", "equivalence": "equivalent" } ] }, { "extension": [ { "extension": [ { "url": "type", "valueCode": "DTM" }, { "url": "cardinalityMin", "valueInteger": 1 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-17", "display": "Device Manufacture Date", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "dateTime" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "manufactureDate", "display": "manufactureDate", "equivalence": "equivalent" } ] }, { "extension": [ { "extension": [ { "url": "type", "valueCode": "DTM" }, { "url": "cardinalityMin", "valueInteger": 1 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-18", "display": "Device Expiry Date", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "dateTime" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "expirationDate", "display": "expirationDate", "equivalence": "equivalent" } ] }, { "extension": [ { "extension": [ { "url": "type", "valueCode": "ST" }, { "url": "cardinalityMin", "valueInteger": 1 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-19", "display": "Device Lot Number", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "string" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "lotNumber", "display": "lotNumber", "equivalence": "equivalent" } ] }, { "extension": [ { "extension": [ { "url": "type", "valueCode": "ST" }, { "url": "cardinalityMin", "valueInteger": 1 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-20", "display": "Device Serial Number", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "string" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "serialNumber", "display": "serialNumber", "equivalence": "equivalent" } ] }, { "extension": [ { "extension": [ { "url": "type", "valueCode": "EI" }, { "url": "cardinalityMin", "valueInteger": 1 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-21", "display": "Device Donation Identification", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "string" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "distinctIdentifier", "display": "distinctIdentifier", "equivalence": "equivalent" } ] }, { "extension": [ { "extension": [ { "url": "type", "valueCode": "CNE" }, { "url": "cardinalityMin", "valueInteger": 1 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "PRT-22", "display": "Device Type", "target": [ { "extension": [ { "extension": [ { "url": "type", "valueCode": "CodeableConcept" }, { "url": "cardinalityMin", "valueInteger": 0 }, { "url": "cardinalityMax", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo" } ], "code": "type", "display": "type", "equivalence": "equivalent" } ] } ] } ] }