FHIR © HL7.org  |  FHIRsmith 0.18.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.rtq-ig
Resource TypeCodeSystem
IdCodeSystem-rtq-assessment-outcome.json
FHIR VersionR5
Sourcehttps://build.fhir.org/ig/HL7/rtq-ig/CodeSystem-rtq-assessment-outcome.html
URLhttp://hl7.org/fhir/uv/rtq/CodeSystem/rtq-assessment-outcome
Version0.2.0
Statusdraft
Date2026-10-25
NameRtqAssessmentOutcomeCS
TitleRTQ Assessment Outcome Code System
Realmuv
Authorityhl7
DescriptionThe regulator's assessment of the company's response to a question, carried on that question when it is re-issued in a follow-up question set. Mirrors the per-question conclusion used in regulatory assessment templates (e.g., issue resolved / not resolved / additional resulting questions).
Contentcomplete

Resources that use this resource

ValueSet
hl7.fhir.uv.rtq-ig#currentrtq-assessment-outcome-vsRTQ Assessment Outcome Value Set

Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: CodeSystem rtq-assessment-outcome

This case-sensitive code system http://hl7.org/fhir/uv/rtq/CodeSystem/rtq-assessment-outcome defines the following codes:

CodeDisplayDefinition
resolved ResolvedThe regulator accepts the response. The question is closed and no further answer is expected.
not-resolved Not ResolvedThe response is not accepted. The question remains open and must be answered again in the next response.
further-questions Raises Further QuestionsThe response raises follow-up questions. The follow-up questions are carried as child items of this question and must each be answered.

Source1

{
  "resourceType": "CodeSystem",
  "id": "rtq-assessment-outcome",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "brr"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "informative",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/rtq/ImplementationGuide/hl7.fhir.uv.rtq-ig"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/rtq/CodeSystem/rtq-assessment-outcome",
  "version": "0.2.0",
  "name": "RtqAssessmentOutcomeCS",
  "title": "RTQ Assessment Outcome Code System",
  "status": "draft",
  "experimental": true,
  "date": "2026-10-25",
  "publisher": "HL7 International / Biomedical Research and Regulation",
  "contact": [
    {
      "name": "HL7 International / Biomedical Research and Regulation",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/rcrim"
        }
      ]
    }
  ],
  "description": "The regulator's assessment of the company's response to a question, carried on that question when it is re-issued in a follow-up question set. Mirrors the per-question conclusion used in regulatory assessment templates (e.g., issue resolved / not resolved / additional resulting questions).",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "caseSensitive": true,
  "content": "complete",
  "count": 3,
  "concept": [
    {
      "code": "resolved",
      "display": "Resolved",
      "definition": "The regulator accepts the response. The question is closed and no further answer is expected."
    },
    {
      "code": "not-resolved",
      "display": "Not Resolved",
      "definition": "The response is not accepted. The question remains open and must be answered again in the next response."
    },
    {
      "code": "further-questions",
      "display": "Raises Further Questions",
      "definition": "The response raises follow-up questions. The follow-up questions are carried as child items of this question and must each be answered."
    }
  ]
}