FHIR IG Statistics: ValueSet/component-radiation-dose-summary-vs
Resources that use this resource
Resources that this resource uses
CodeSystem |
sct | SNOMED CT (all versions) |
DCM | DICOM Controlled Terminology |
sct | SNOMED codes used in this IG |
sct | veri |
DCM | DICOM Controlled Terminology Definitions |
Narrative
Note: links and images are rebased to the (stated) source
This value set includes codes based on the following rules:
- Include these codes as defined in
http://dicom.nema.org/resources/ontology/DCM
version 2025.2.20250411
Code | Display | Definition |
113813 | CT Dose Length Product Total | The total dose length product for the defined scope of accumulation. |
113725 | Dose (RP) Total | Total Dose related to Reference Point (RP). (in the scope of the including report). |
111637 | Accumulated Average Glandular Dose | Average Glandular Dose to a single breast accumulated over multiple images. |
113722 | Dose Area Product Total | Total calculated Dose Area Product (in the scope of the including report). |
113726 | Fluoro Dose Area Product Total | Total calculated Dose Area Product applied in Fluoroscopy Modes (in the scope of the including report). |
113727 | Acquisition Dose Area Product Total | Total calculated Dose Area Product applied in Acquisition Modes (in the scope of the including report). |
113730 | Total Fluoro Time | Total accumulated clock time of Fluoroscopy in the scope of the including report (i.e., the sum of the Irradiation Duration values for accumulated fluoroscopy irradiation events). |
113731 | Total Number of Radiographic Frames | Accumulated Count of exposure pulses (single or multi-frame encoded) created from irradiation events performed with high dose (acquisition). |
113507 | Administered activity | The calculated activity at the Radiopharmaceutical Start Time when the radiopharmaceutical is administered to the patient. The residual activity (i.e., radiopharmaceutical not administered) , if measured, is reflected in the calculated value. The estimated extravasation is not reflected in the calculated value. |
123005 | Radiopharmaceutical Volume | Volume of radiopharmaceutical administered to the patient. |
- Include these codes as defined in
http://snomed.info/sct
Source
{
"resourceType": "ValueSet",
"id": "component-radiation-dose-summary-vs",
"text": {
"status": "extensions",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "ii"
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger": 2,
"_valueInteger": {
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueCanonical": "http://hl7.org/fhir/uv/radiation-dose-summary/ImplementationGuide/hl7.fhir.uv.radiation-dose-summary"
}
]
}
},
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueCode": "trial-use",
"_valueCode": {
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
"valueCanonical": "http://hl7.org/fhir/uv/radiation-dose-summary/ImplementationGuide/hl7.fhir.uv.radiation-dose-summary"
}
]
}
}
],
"url": "http://hl7.org/fhir/uv/radiation-dose-summary/ValueSet/component-radiation-dose-summary-vs",
"version": "1.0.0",
"name": "ComponentRadiationDoseSummaryVS",
"title": "Radiation Dose Summary component type",
"status": "active",
"experimental": false,
"date": "2025-05-01T13:56:44+00:00",
"publisher": "HL7 International / Imaging Integration",
"contact": [
{
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name": "HL7 Imaging Integration Workgroup",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name": "Abderrazek Boufahja",
"telecom": [
{
"system": "email",
"value": "abderrazek.boufahja@gehealthcare.com"
}
]
}
],
"description": "Value Set describing the list of minimal dose information related to Procedure and Administration level",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001"
}
]
}
],
"copyright": "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.",
"compose": {
"include": [
{
"system": "http://dicom.nema.org/resources/ontology/DCM",
"version": "2025.2.20250411",
"concept": [
{
"code": "113813",
"display": "CT Dose Length Product Total"
},
{
"code": "113725",
"display": "Dose (RP) Total"
},
{
"code": "111637",
"display": "Accumulated Average Glandular Dose"
},
{
"code": "113722",
"display": "Dose Area Product Total"
},
{
"code": "113726",
"display": "Fluoro Dose Area Product Total"
},
{
"code": "113727",
"display": "Acquisition Dose Area Product Total"
},
{
"code": "113730",
"display": "Total Fluoro Time"
},
{
"code": "113731",
"display": "Total Number of Radiographic Frames"
},
{
"code": "113507",
"display": "Administered activity"
},
{
"code": "123005",
"display": "Radiopharmaceutical Volume"
}
]
},
{
"system": "http://snomed.info/sct",
"concept": [
{
"code": "349358000",
"display": "Radiopharmaceuticals"
},
{
"code": "89457008",
"display": "Radioisotope"
},
{
"code": "410675002",
"display": "Route of administration"
}
]
}
]
}
}