FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: ValueSet/component-radiation-dose-summary-vs

Packagehl7.fhir.uv.radiation-dose-summary
TypeValueSet
Idcomponent-radiation-dose-summary-vs
FHIR VersionR4
Sourcehttp://hl7.org/fhir/uv/radiation-dose-summary/https://build.fhir.org/ig/HL7/fhir-radiation-dose-summary-ig/ValueSet-component-radiation-dose-summary-vs.html
URLhttp://hl7.org/fhir/uv/radiation-dose-summary/ValueSet/component-radiation-dose-summary-vs
Version1.0.0
Statusactive
Date2025-05-01T13:56:44+00:00
NameComponentRadiationDoseSummaryVS
TitleRadiation Dose Summary component type
Realmuv
Authorityhl7
DescriptionValue Set describing the list of minimal dose information related to Procedure and Administration level
CopyrightThis value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.

Resources that use this resource

StructureDefinition
radiation-dose-summaryRadiation Dose Summary

Resources that this resource uses

CodeSystem
sctSNOMED CT (all versions)
DCMDICOM Controlled Terminology
sctSNOMED codes used in this IG
sctveri
DCMDICOM Controlled Terminology Definitions

Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ValueSet component-radiation-dose-summary-vs

This value set includes codes based on the following rules:

  • Include these codes as defined in http://dicom.nema.org/resources/ontology/DCM version 2025.2.20250411
    CodeDisplayDefinition
    113813CT Dose Length Product TotalThe total dose length product for the defined scope of accumulation.
    113725Dose (RP) TotalTotal Dose related to Reference Point (RP). (in the scope of the including report).
    111637Accumulated Average Glandular DoseAverage Glandular Dose to a single breast accumulated over multiple images.
    113722Dose Area Product TotalTotal calculated Dose Area Product (in the scope of the including report).
    113726Fluoro Dose Area Product TotalTotal calculated Dose Area Product applied in Fluoroscopy Modes (in the scope of the including report).
    113727Acquisition Dose Area Product TotalTotal calculated Dose Area Product applied in Acquisition Modes (in the scope of the including report).
    113730Total Fluoro TimeTotal accumulated clock time of Fluoroscopy in the scope of the including report (i.e., the sum of the Irradiation Duration values for accumulated fluoroscopy irradiation events).
    113731Total Number of Radiographic FramesAccumulated Count of exposure pulses (single or multi-frame encoded) created from irradiation events performed with high dose (acquisition).
    113507Administered activityThe calculated activity at the Radiopharmaceutical Start Time when the radiopharmaceutical is administered to the patient. The residual activity (i.e., radiopharmaceutical not administered) , if measured, is reflected in the calculated value. The estimated extravasation is not reflected in the calculated value.
    123005Radiopharmaceutical VolumeVolume of radiopharmaceutical administered to the patient.
  • Include these codes as defined in http://snomed.info/sct
    CodeDisplay
    349358000Radiopharmaceuticals
    89457008Radioisotope
    410675002Route of administration

Source

{
  "resourceType": "ValueSet",
  "id": "component-radiation-dose-summary-vs",
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "ii"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 2,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/radiation-dose-summary/ImplementationGuide/hl7.fhir.uv.radiation-dose-summary"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/radiation-dose-summary/ImplementationGuide/hl7.fhir.uv.radiation-dose-summary"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/radiation-dose-summary/ValueSet/component-radiation-dose-summary-vs",
  "version": "1.0.0",
  "name": "ComponentRadiationDoseSummaryVS",
  "title": "Radiation Dose Summary component type",
  "status": "active",
  "experimental": false,
  "date": "2025-05-01T13:56:44+00:00",
  "publisher": "HL7 International / Imaging Integration",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name": "HL7 Imaging Integration Workgroup",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name": "Abderrazek Boufahja",
      "telecom": [
        {
          "system": "email",
          "value": "abderrazek.boufahja@gehealthcare.com"
        }
      ]
    }
  ],
  "description": "Value Set describing the list of minimal dose information related to Procedure and Administration level",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001"
        }
      ]
    }
  ],
  "copyright": "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.",
  "compose": {
    "include": [
      {
        "system": "http://dicom.nema.org/resources/ontology/DCM",
        "version": "2025.2.20250411",
        "concept": [
          {
            "code": "113813",
            "display": "CT Dose Length Product Total"
          },
          {
            "code": "113725",
            "display": "Dose (RP) Total"
          },
          {
            "code": "111637",
            "display": "Accumulated Average Glandular Dose"
          },
          {
            "code": "113722",
            "display": "Dose Area Product Total"
          },
          {
            "code": "113726",
            "display": "Fluoro Dose Area Product Total"
          },
          {
            "code": "113727",
            "display": "Acquisition Dose Area Product Total"
          },
          {
            "code": "113730",
            "display": "Total Fluoro Time"
          },
          {
            "code": "113731",
            "display": "Total Number of Radiographic Frames"
          },
          {
            "code": "113507",
            "display": "Administered activity"
          },
          {
            "code": "123005",
            "display": "Radiopharmaceutical Volume"
          }
        ]
      },
      {
        "system": "http://snomed.info/sct",
        "concept": [
          {
            "code": "349358000",
            "display": "Radiopharmaceuticals"
          },
          {
            "code": "89457008",
            "display": "Radioisotope"
          },
          {
            "code": "410675002",
            "display": "Route of administration"
          }
        ]
      }
    ]
  }
}