FHIR IG analytics| Package | hl7.fhir.uv.phd.r4b |
| Resource Type | Device |
| Id | Device-phd-00601900010E9234.F45EABA80832.json |
| FHIR Version | R4B |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: Device phd-00601900010E9234.F45EABA80832
Profile: PhdDevice
identifier: IEEE 11073 System Identifier/00-60-19-00-01-0E-92-34, Bluetooth MAC address/F4-5E-AB-A8-08-32
manufacturer: Diabetes Care
serialNumber: 20130200002A
modelNumber: Gluc-23
type: Simple PHD
| SystemType | Version |
| Glucose Monitor | 1 |
version
type: Firmware revision
value: GLU.7AJ-02
version
type: Software revision
value: 3.55.6
version
type: Hardware revision
value: 5.4.2
property
type: Certified device list as transport-specialization combo
valueCode: HDP BT Glucose Monitor certified
property
type: Time synchronization protocol
valueCode: None
property
type: USB PID and VID designators
valueCode: VID_1234:PID_5678
{
"resourceType": "Device",
"id": "phd-00601900010E9234.F45EABA80832",
"meta": {
"profile": [
"http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"
]
},
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"identifier": [
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code": "SYSID"
}
]
},
"system": "urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680",
"value": "00-60-19-00-01-0E-92-34"
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code": "BTMAC"
}
]
},
"system": "http://hl7.org/fhir/sid/eui-48/bluetooth",
"value": "F4-5E-AB-A8-08-32"
}
],
"manufacturer": "Diabetes Care",
"serialNumber": "20130200002A",
"modelNumber": "Gluc-23",
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "65573",
"display": "MDC_MOC_VMS_MDS_SIMP"
}
],
"text": "Simple PHD"
},
"specialization": [
{
"systemType": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "528401",
"display": "MDC_DEV_SPEC_PROFILE_GLUCOSE"
}
],
"text": "Glucose Monitor"
},
"version": "1"
}
],
"version": [
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "531976",
"display": "MDC_ID_PROD_SPEC_FW"
}
],
"text": "Firmware revision"
},
"value": "GLU.7AJ-02"
},
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "531975",
"display": "MDC_ID_PROD_SPEC_SW"
}
],
"text": "Software revision"
},
"value": "3.55.6"
},
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "531974",
"display": "MDC_ID_PROD_SPEC_HW"
}
],
"text": "Hardware revision"
},
"value": "5.4.2"
}
],
"property": [
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "532353",
"display": "MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"
}
],
"text": "Certified device list as transport-specialization combo"
},
"valueCode": [
{
"coding": [
{
"system": "http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHDInterfaceIDs",
"code": "16401",
"display": "HDP BT Glucose Monitor certified"
}
]
}
]
},
{
"type": {
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "68220",
"display": "MDC_TIME_SYNC_PROTOCOL"
}
],
"text": "Time synchronization protocol"
},
"valueCode": [
{
"coding": [
{
"system": "urn:iso:std:iso:11073:10101",
"code": "532224",
"display": "MDC_TIME_SYNC_NONE"
}
],
"text": "None"
}
]
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers",
"code": "USB"
}
]
},
"valueCode": [
{
"text": "VID_1234:PID_5678"
}
]
}
]
}