FHIR IG analytics| Package | hl7.fhir.uv.order-catalog |
| Resource Type | SpecimenDefinition |
| Id | SpecimenDefinition-example-specimen-capillary-serum-single-test.json |
| FHIR Version | R5 |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: SpecimenDefinition example-specimen-capillary-serum-single-test
Language: en-US
Profile: Laboratory IVD Specimen Definition
status: Active
typeCollected: Capillary blood specimen (specimen)
collection: Capillary specimen collection (procedure)
typeTested
type: Serum
preference: Preferred
Containers
Material Type Cap Description Capacity MinimumVolume[x] plastic Evacuated blood collection tube with clot activator red cap red cap plastic tube 2 mL
2 milliliter (Details: UCUM codemL = 'mL') 0.5 milliliter (Details: UCUM codemL = 'mL') RetentionTimes
Value Unit System Code 24 hour http://unitsofmeasure.org h rejectionCriterion: blood specimen hemolized, insufficient quantity of specimen
handling
temperatureQualifier: room temperature or refrigerated
MaxDurations
Value Unit System Code 7 day http://unitsofmeasure.org d handling
temperatureQualifier: frozen
MaxDurations
Value Unit System Code 28 day http://unitsofmeasure.org d
typeTested
type: Plasma
preference: Alternate
Containers
Type Cap Description Capacity MinimumVolume[x] Evacuated blood collection tube with heparin lithium and gel separator green cap green cap plastic tube 2 mL
2 milliliter (Details: UCUM codemL = 'mL') 0.5 milliliter (Details: UCUM codemL = 'mL') RetentionTimes
Value Unit System Code 24 hour http://unitsofmeasure.org h rejectionCriterion: blood specimen hemolized, insufficient quantity of specimen
handling
temperatureQualifier: room temperature or refrigerated
MaxDurations
Value Unit System Code 7 day http://unitsofmeasure.org d handling
temperatureQualifier: frozen
MaxDurations
Value Unit System Code 28 day http://unitsofmeasure.org d
{
"resourceType": "SpecimenDefinition",
"id": "example-specimen-capillary-serum-single-test",
"meta": {
"profile": [
"http://hl7.org/fhir/uv/order-catalog/StructureDefinition/LabSpecimenDefinition"
]
},
"language": "en-US",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"status": "active",
"typeCollected": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "122554006",
"display": "Capillary blood specimen (specimen)"
}
]
},
"collection": [
{
"coding": [
{
"system": "http://snomed.info/sct",
"code": "1048003",
"display": "Capillary specimen collection (procedure)"
}
]
}
],
"typeTested": [
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0487",
"code": "SER",
"display": "Serum"
}
]
},
"preference": "preferred",
"container": {
"material": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "61088005",
"display": "Plastic"
}
],
"text": "plastic"
},
"type": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "767384004",
"display": "Evacuated blood collection tube with clot activator"
}
]
},
"cap": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/container-cap",
"code": "red"
}
],
"text": "red cap"
},
"description": "red cap plastic tube 2 mL",
"capacity": {
"value": 2,
"unit": "milliliter",
"system": "http://unitsofmeasure.org",
"code": "mL"
},
"minimumVolumeQuantity": {
"value": 0.5,
"unit": "milliliter",
"system": "http://unitsofmeasure.org",
"code": "mL"
}
},
"retentionTime": {
"value": 24,
"unit": "hour",
"system": "http://unitsofmeasure.org",
"code": "h"
},
"rejectionCriterion": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/rejection-criteria",
"code": "hemolized"
}
],
"text": "blood specimen hemolized"
},
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/rejection-criteria",
"code": "insufficient"
}
],
"text": "insufficient quantity of specimen"
}
],
"handling": [
{
"temperatureQualifier": {
"text": "room temperature or refrigerated"
},
"maxDuration": {
"value": 7,
"unit": "day",
"system": "http://unitsofmeasure.org",
"code": "d"
}
},
{
"temperatureQualifier": {
"text": "frozen"
},
"maxDuration": {
"value": 28,
"unit": "day",
"system": "http://unitsofmeasure.org",
"code": "d"
}
}
]
},
{
"type": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0487",
"code": "PLAS",
"display": "Plasma"
}
]
},
"preference": "alternate",
"container": {
"type": {
"coding": [
{
"system": "http://snomed.info/sct",
"code": "767390000",
"display": "Evacuated blood collection tube with heparin lithium and gel separator"
}
]
},
"cap": {
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/container-cap",
"code": "green"
}
],
"text": "green cap"
},
"description": "green cap plastic tube 2 mL",
"capacity": {
"value": 2,
"unit": "milliliter",
"system": "http://unitsofmeasure.org",
"code": "mL"
},
"minimumVolumeQuantity": {
"value": 0.5,
"unit": "milliliter",
"system": "http://unitsofmeasure.org",
"code": "mL"
}
},
"retentionTime": {
"value": 24,
"unit": "hour",
"system": "http://unitsofmeasure.org",
"code": "h"
},
"rejectionCriterion": [
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/rejection-criteria",
"code": "hemolized"
}
],
"text": "blood specimen hemolized"
},
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/rejection-criteria",
"code": "insufficient"
}
],
"text": "insufficient quantity of specimen"
}
],
"handling": [
{
"temperatureQualifier": {
"text": "room temperature or refrigerated"
},
"maxDuration": {
"value": 7,
"unit": "day",
"system": "http://unitsofmeasure.org",
"code": "d"
}
},
{
"temperatureQualifier": {
"text": "frozen"
},
"maxDuration": {
"value": 28,
"unit": "day",
"system": "http://unitsofmeasure.org",
"code": "d"
}
}
]
}
]
}