FHIR IG analytics| Package | hl7.fhir.uv.imaging-service-request-ig |
| Resource Type | ConceptMap |
| Id | ConceptMap-hl7v2-orm-to-fhir.json |
| FHIR Version | R6 |
| Source | https://build.fhir.org/ig/HL7/imaging-service-request-ig/ConceptMap-hl7v2-orm-to-fhir.html |
| URL | http://hl7.org/fhir/uv/imaging-service-request-ig/ConceptMap/hl7v2-orm-to-fhir |
| Version | 0.1.0 |
| Status | draft |
| Date | 2026-09-19T16:32:04+00:00 |
| Name | HL7V2ORMToFHIR |
| Title | ConceptMap - Populating FHIR Resources from HL7 v2.3.1 ORM/OMG Order Messages |
| Realm | uv |
| Authority | hl7 |
| Description | Mapping HL7 v2.3.1 ORM (and v2.5.1 OMG) segments used in RAD-2 and RAD-3 to the Imaging Service Request FHIR resources |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap hl7v2-orm-to-fhir
This mapping does not specify any particular context of use.
Group 1 Mapping from https://www.hl7.org/Special/committees/imagemgt to http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition
| Source Code | Relationship | Target Code |
| MSH-9 (Message Type (ORM^O01 / OMG^O19)) | (not mapped) | |
Group 2 Mapping from https://www.hl7.org/Special/committees/imagemgt to http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition
| Source Concept Details | Relationship | Target Concept Details | Comment | |||
| Codes from https://www.hl7.org/Special/committees/imagemgt | Transaction | Codes from http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition | ||||
| PID-3 | Patient Identifier List | RAD-2 | is equivalent to | imaging-patient.identifier | ImagingPatient.identifier | |
| PID-5 | Patient Name | RAD-2 | is equivalent to | imaging-patient.name | ImagingPatient.name | |
| PID-18 | Patient Account Number | RAD-2 | is equivalent to | imaging-visit.identifier | ImagingVisit.identifier | At least one of PID-18 or PV1-19 shall be valued per RAD-2/RAD-3; represented as the Visit identifier |
Group 3 Mapping from https://www.hl7.org/Special/committees/imagemgt to http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition
| Source Concept Details | Relationship | Target Concept Details | Comment | ||||
| Codes from https://www.hl7.org/Special/committees/imagemgt | Transaction | ResourceType | Codes from http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition | ||||
| PV1-2 | Patient Class | RAD-2 | is equivalent to | imaging-visit.class | ImagingVisit.class | ||
| PV1-8 | Referring Doctor | RAD-2 | Practitioner | is equivalent to | imaging-service-request.requester | ImagingServiceRequest.requester | Populated in RAD-2 New Order messages; not required for RAD-3 status update / cancellation messages |
| PV1-19 | Visit Number | RAD-2 | is equivalent to | imaging-visit.identifier | ImagingVisit.identifier | ||
Group 4 Mapping from https://www.hl7.org/Special/committees/imagemgt to http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition
| Source Concept Details | Relationship | Target Concept Details | Comment | |||||
| Codes from https://www.hl7.org/Special/committees/imagemgt | Transaction | ResourceType | IdentifierType | Codes from http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition | ||||
| ORC-1 | Order Control | RAD-2 | is equivalent to | imaging-service-request.status | ImagingServiceRequest.status | RAD-2 values: NW (new), PA (parent), CH (child), CA (cancel), DC (discontinue) - Order Placer initiated | ||
| RAD-3 | is equivalent to | imaging-service-request.status | ImagingServiceRequest.status | RAD-3 values: SN (new), XX (change), NA (ORR/ORG acknowledgement), OC (cancelled by filler) - DSS/Order Filler initiated | ||||
| ORC-2 | Placer Order Number | RAD-2 | is equivalent to | imaging-service-request.identifier | ImagingServiceRequest.identifier[placerOrder] | RAD-2: valued by the Order Placer on the New Order message. RAD-3: omitted on the DSS/Order Filler's New Order message and valued by the Order Placer in the ORR/ORG acknowledgement | ||
| ORC-3 | Filler Order Number | RAD-3 | is equivalent to | imaging-service-request.identifier | ImagingServiceRequest.identifier[fillerOrder] | RAD-2: shall not be present. RAD-3: required, valued by the DSS/Order Filler | ||
| ORC-5 | Order Status | RAD-3 | is equivalent to | imaging-service-request.status | ImagingServiceRequest.status | CM=completed, DC=discontinued, IP=in progress; carried on the RAD-3 Order Status Update message only | ||
| ORC-7 | Quantity/Timing | RAD-2 | is equivalent to | imaging-requested-procedure.occurrenceDateTime | RequestedProcedure.occurrenceDateTime | HL7 v2.3.1 only; superseded by TQ1-7 in v2.5.1/OMG. Required on RAD-2 New Order; present on RAD-3 New/Change Order | ||
| ORC-9 | Date/Time of Transaction | RAD-2 | is equivalent to | imaging-service-request.authoredOn | ImagingServiceRequest.authoredOn | |||
| ORC-12 | Ordering Provider | RAD-2 | Practitioner | is equivalent to | imaging-service-request.requester | ImagingServiceRequest.requester | ||
| ORC-17 | Entering Organization | RAD-2 | Organization | is equivalent to | imaging-organization | ImagingOrganization | ||
Group 5 Mapping from https://www.hl7.org/Special/committees/imagemgt to http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition
| Source Concept Details | Relationship | Target Concept Details | Comment | |||
| Codes from https://www.hl7.org/Special/committees/imagemgt | Transaction | Codes from http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition | ||||
| TQ1-7 | Start Date/Time | RAD-2 | is equivalent to | imaging-requested-procedure.occurrenceDateTime | RequestedProcedure.occurrenceDateTime | HL7 v2.5.1 / OMG only; carries the exam start date/time in place of deprecated ORC-7.4/OBR-27.4 |
Group 6 Mapping from https://www.hl7.org/Special/committees/imagemgt to http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition
| Source Concept Details | Relationship | Target Concept Details | Comment | ||||
| Codes from https://www.hl7.org/Special/committees/imagemgt | Transaction | ResourceType | Codes from http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition | ||||
| OBR-2 | Placer Order Number | RAD-2 | is equivalent to | imaging-service-request.identifier | ImagingServiceRequest.identifier[placerOrder] | ||
| OBR-3 | Filler Order Number | RAD-3 | is equivalent to | imaging-service-request.identifier | ImagingServiceRequest.identifier[fillerOrder] | RAD-2: not present. RAD-3: required, valued by the DSS/Order Filler | |
| OBR-4 | Universal Service ID | RAD-2 | is equivalent to | imaging-service-request.code | ImagingServiceRequest.code | ||
| OBR-6 | Requested Date/Time | RAD-2 | is equivalent to | imaging-service-request.occurrenceDateTime | ImagingServiceRequest.occurrenceDateTime | ||
| OBR-12 | Danger Code | RAD-2 | is equivalent to | imaging-service-request.note | ImagingServiceRequest.note | ||
| OBR-13 | Relevant Clinical Info. | RAD-2 | is equivalent to | imaging-service-request.note | ImagingServiceRequest.note | ||
| OBR-16 | Ordering Provider | RAD-2 | Practitioner | is equivalent to | imaging-service-request.requester | ImagingServiceRequest.requester | |
| OBR-27 | Quantity/Timing | RAD-2 | is equivalent to | imaging-requested-procedure.occurrenceDateTime | RequestedProcedure.occurrenceDateTime | HL7 v2.3.1 only; superseded by TQ1-7 in v2.5.1/OMG | |
| OBR-30 | Transportation Mode | RAD-2 | Task | is equivalent to | imaging-scheduled-procedure-step | ScheduledProcedureStep | No dedicated FHIR element currently modeled; candidate for a Task extension |
| OBR-31 | Reason for Study | RAD-2 | is equivalent to | imaging-service-request.reasonCode | ImagingServiceRequest.reasonCode | ||
| OBR-41 | Transport Arranged | RAD-2 | Task | is equivalent to | imaging-scheduled-procedure-step | ScheduledProcedureStep | No dedicated FHIR element currently modeled; candidate for a Task extension |
Group 7 Mapping from https://www.hl7.org/Special/committees/imagemgt to http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition
| Source Concept Details | Relationship | Target Concept Details | Comment | |||
| Codes from https://www.hl7.org/Special/committees/imagemgt | Transaction | Codes from http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition | ||||
| MSA-1 | Acknowledgement Code | (not mapped) | ||||
| ERR-1 | Error Code and Location | RAD-3 | is equivalent to | OperationOutcome | OperationOutcome | RAD-3 ORR (Error) / ORG (Error) acknowledgement |
{
"resourceType": "ConceptMap",
"id": "hl7v2-orm-to-fhir",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "ii"
}
],
"url": "http://hl7.org/fhir/uv/imaging-service-request-ig/ConceptMap/hl7v2-orm-to-fhir",
"version": "0.1.0",
"name": "HL7V2ORMToFHIR",
"title": "ConceptMap - Populating FHIR Resources from HL7 v2.3.1 ORM/OMG Order Messages",
"status": "draft",
"experimental": true,
"date": "2026-09-19T16:32:04+00:00",
"publisher": "HL7 International / Imaging Integration",
"contact": [
{
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt/index.cfm"
}
]
},
{
"name": "HL7 International / Imaging Integration",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt/index.cfm"
}
]
},
{
"name": "Jonathan Whitby",
"telecom": [
{
"system": "email",
"value": "jonathan.whitby@mi.medical.canon"
}
]
},
{
"name": "Brian Bialecki",
"telecom": [
{
"system": "email",
"value": "bbialecki@acr.org"
}
]
},
{
"name": "Bas van den Heuvel",
"telecom": [
{
"system": "email",
"value": "bas.van.den.heuvel@philips.com"
}
]
}
],
"description": "Mapping HL7 v2.3.1 ORM (and v2.5.1 OMG) segments used in RAD-2 and RAD-3 to the Imaging Service Request FHIR resources",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001"
}
]
}
],
"additionalAttribute": [
{
"code": "ResourceType",
"uri": "http://hl7.org/fhir/ValueSet/resource-types",
"description": "FHIR Resource Reference Type",
"type": "code"
},
{
"code": "HL7Version",
"description": "HL7 Version to which the source segment/field applies",
"type": "string"
},
{
"code": "Transaction",
"description": "IHE RAD transaction(s) (RAD-2 Placer Order Management and/or RAD-3 Filler Order Management) in which the source segment/field is used",
"type": "code"
}
],
"group": [
{
"source": "https://www.hl7.org/Special/committees/imagemgt",
"target": "http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition",
"element": [
{
"code": "MSH-9",
"display": "Message Type (ORM^O01 / OMG^O19)",
"noMap": true
}
]
},
{
"source": "https://www.hl7.org/Special/committees/imagemgt",
"target": "http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition",
"element": [
{
"code": "PID-3",
"display": "Patient Identifier List",
"target": [
{
"code": "imaging-patient.identifier",
"display": "ImagingPatient.identifier",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "PID-5",
"display": "Patient Name",
"target": [
{
"code": "imaging-patient.name",
"display": "ImagingPatient.name",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "PID-18",
"display": "Patient Account Number",
"target": [
{
"code": "imaging-visit.identifier",
"display": "ImagingVisit.identifier",
"relationship": "equivalent",
"comment": "At least one of PID-18 or PV1-19 shall be valued per RAD-2/RAD-3; represented as the Visit identifier",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
}
]
},
{
"source": "https://www.hl7.org/Special/committees/imagemgt",
"target": "http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition",
"element": [
{
"code": "PV1-2",
"display": "Patient Class",
"target": [
{
"code": "imaging-visit.class",
"display": "ImagingVisit.class",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "PV1-8",
"display": "Referring Doctor",
"target": [
{
"code": "imaging-service-request.requester",
"display": "ImagingServiceRequest.requester",
"relationship": "equivalent",
"comment": "Populated in RAD-2 New Order messages; not required for RAD-3 status update / cancellation messages",
"dependsOn": [
{
"attribute": "ResourceType",
"valueCode": "Practitioner"
},
{
"attribute": "Transaction",
"valueCode": "RAD-2"
}
]
}
]
},
{
"code": "PV1-19",
"display": "Visit Number",
"target": [
{
"code": "imaging-visit.identifier",
"display": "ImagingVisit.identifier",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
}
]
},
{
"source": "https://www.hl7.org/Special/committees/imagemgt",
"target": "http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition",
"element": [
{
"code": "ORC-1",
"display": "Order Control",
"target": [
{
"code": "imaging-service-request.status",
"display": "ImagingServiceRequest.status",
"relationship": "equivalent",
"comment": "RAD-2 values: NW (new), PA (parent), CH (child), CA (cancel), DC (discontinue) - Order Placer initiated",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
}
]
},
{
"code": "imaging-service-request.status",
"display": "ImagingServiceRequest.status",
"relationship": "equivalent",
"comment": "RAD-3 values: SN (new), XX (change), NA (ORR/ORG acknowledgement), OC (cancelled by filler) - DSS/Order Filler initiated",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "ORC-2",
"display": "Placer Order Number",
"target": [
{
"code": "imaging-service-request.identifier",
"display": "ImagingServiceRequest.identifier[placerOrder]",
"relationship": "equivalent",
"comment": "RAD-2: valued by the Order Placer on the New Order message. RAD-3: omitted on the DSS/Order Filler's New Order message and valued by the Order Placer in the ORR/ORG acknowledgement",
"dependsOn": [
{
"attribute": "IdentifierType",
"valueCoding": {
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "PLAC"
}
},
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "ORC-3",
"display": "Filler Order Number",
"target": [
{
"code": "imaging-service-request.identifier",
"display": "ImagingServiceRequest.identifier[fillerOrder]",
"relationship": "equivalent",
"comment": "RAD-2: shall not be present. RAD-3: required, valued by the DSS/Order Filler",
"dependsOn": [
{
"attribute": "IdentifierType",
"valueCoding": {
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "FILL"
}
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "ORC-5",
"display": "Order Status",
"target": [
{
"code": "imaging-service-request.status",
"display": "ImagingServiceRequest.status",
"relationship": "equivalent",
"comment": "CM=completed, DC=discontinued, IP=in progress; carried on the RAD-3 Order Status Update message only",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "ORC-7",
"display": "Quantity/Timing",
"target": [
{
"code": "imaging-requested-procedure.occurrenceDateTime",
"display": "RequestedProcedure.occurrenceDateTime",
"relationship": "equivalent",
"comment": "HL7 v2.3.1 only; superseded by TQ1-7 in v2.5.1/OMG. Required on RAD-2 New Order; present on RAD-3 New/Change Order",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "ORC-9",
"display": "Date/Time of Transaction",
"target": [
{
"code": "imaging-service-request.authoredOn",
"display": "ImagingServiceRequest.authoredOn",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "ORC-12",
"display": "Ordering Provider",
"target": [
{
"code": "imaging-service-request.requester",
"display": "ImagingServiceRequest.requester",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "ResourceType",
"valueCode": "Practitioner"
},
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "ORC-17",
"display": "Entering Organization",
"target": [
{
"code": "imaging-organization",
"display": "ImagingOrganization",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "ResourceType",
"valueCode": "Organization"
},
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
}
]
},
{
"source": "https://www.hl7.org/Special/committees/imagemgt",
"target": "http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition",
"element": [
{
"code": "TQ1-7",
"display": "Start Date/Time",
"target": [
{
"code": "imaging-requested-procedure.occurrenceDateTime",
"display": "RequestedProcedure.occurrenceDateTime",
"relationship": "equivalent",
"comment": "HL7 v2.5.1 / OMG only; carries the exam start date/time in place of deprecated ORC-7.4/OBR-27.4",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
}
]
},
{
"source": "https://www.hl7.org/Special/committees/imagemgt",
"target": "http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition",
"element": [
{
"code": "OBR-2",
"display": "Placer Order Number",
"target": [
{
"code": "imaging-service-request.identifier",
"display": "ImagingServiceRequest.identifier[placerOrder]",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-3",
"display": "Filler Order Number",
"target": [
{
"code": "imaging-service-request.identifier",
"display": "ImagingServiceRequest.identifier[fillerOrder]",
"relationship": "equivalent",
"comment": "RAD-2: not present. RAD-3: required, valued by the DSS/Order Filler",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-4",
"display": "Universal Service ID",
"target": [
{
"code": "imaging-service-request.code",
"display": "ImagingServiceRequest.code",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-6",
"display": "Requested Date/Time",
"target": [
{
"code": "imaging-service-request.occurrenceDateTime",
"display": "ImagingServiceRequest.occurrenceDateTime",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-12",
"display": "Danger Code",
"target": [
{
"code": "imaging-service-request.note",
"display": "ImagingServiceRequest.note",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-13",
"display": "Relevant Clinical Info.",
"target": [
{
"code": "imaging-service-request.note",
"display": "ImagingServiceRequest.note",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-16",
"display": "Ordering Provider",
"target": [
{
"code": "imaging-service-request.requester",
"display": "ImagingServiceRequest.requester",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "ResourceType",
"valueCode": "Practitioner"
},
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-27",
"display": "Quantity/Timing",
"target": [
{
"code": "imaging-requested-procedure.occurrenceDateTime",
"display": "RequestedProcedure.occurrenceDateTime",
"relationship": "equivalent",
"comment": "HL7 v2.3.1 only; superseded by TQ1-7 in v2.5.1/OMG",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-30",
"display": "Transportation Mode",
"target": [
{
"code": "imaging-scheduled-procedure-step",
"display": "ScheduledProcedureStep",
"relationship": "equivalent",
"comment": "No dedicated FHIR element currently modeled; candidate for a Task extension",
"dependsOn": [
{
"attribute": "ResourceType",
"valueCode": "Task"
},
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-31",
"display": "Reason for Study",
"target": [
{
"code": "imaging-service-request.reasonCode",
"display": "ImagingServiceRequest.reasonCode",
"relationship": "equivalent",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
},
{
"code": "OBR-41",
"display": "Transport Arranged",
"target": [
{
"code": "imaging-scheduled-procedure-step",
"display": "ScheduledProcedureStep",
"relationship": "equivalent",
"comment": "No dedicated FHIR element currently modeled; candidate for a Task extension",
"dependsOn": [
{
"attribute": "ResourceType",
"valueCode": "Task"
},
{
"attribute": "Transaction",
"valueCode": "RAD-2"
},
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
}
]
},
{
"source": "https://www.hl7.org/Special/committees/imagemgt",
"target": "http://hl7.org/fhir/uv/imaging-service-request-ig/StructureDefinition",
"element": [
{
"code": "MSA-1",
"display": "Acknowledgement Code",
"noMap": true
},
{
"code": "ERR-1",
"display": "Error Code and Location",
"target": [
{
"code": "OperationOutcome",
"display": "OperationOutcome",
"relationship": "equivalent",
"comment": "RAD-3 ORR (Error) / ORG (Error) acknowledgement",
"dependsOn": [
{
"attribute": "Transaction",
"valueCode": "RAD-3"
}
]
}
]
}
]
}
]
}