FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: SearchParameter/workflow-protectiveFactorRef

Packagehl7.fhir.uv.extensions.r5
TypeSearchParameter
Idworkflow-protectiveFactorRef
FHIR VersionR5
Sourcehttp://hl7.org/fhir/extensions/http://hl7.org/fhir/extensions/5.2.0/SearchParameter-workflow-protectiveFactorRef.html
URLhttp://hl7.org/fhir/SearchParameter/workflow-protectiveFactorRef
Version5.2.0
Statusdraft
Date2025-02-10T21:45:45+11:00
NameProtectiveFactorRefSearchParameter
TitleProtective Factor Reference SearchParameter
Realmuv
Authorityhl7
DescriptionSearchParameter for Protective Factor Extension with Reference data type
Typereference

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: SearchParameter workflow-protectiveFactorRef

ProtectiveFactorRefSearchParameter D

Parameter workflow-protectiveFactorRef:reference

SearchParameter for Protective Factor Extension with Reference data type

ResourcesCarePlan, CommunicationRequest, Goal
ExpressionCarePlan.activity.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference | CommunicationRequest.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference | Goal.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference
Processing ModeNormal
Multiples
  • multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true
  • multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true

Source

{
  "resourceType": "SearchParameter",
  "id": "workflow-protectiveFactorRef",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "draft"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "fhir"
    }
  ],
  "url": "http://hl7.org/fhir/SearchParameter/workflow-protectiveFactorRef",
  "identifier": [
    {
      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:2.16.840.1.113883.4.642.31.4"
    }
  ],
  "version": "5.2.0",
  "name": "ProtectiveFactorRefSearchParameter",
  "title": "Protective Factor Reference SearchParameter",
  "status": "draft",
  "experimental": true,
  "date": "2025-02-10T21:45:45+11:00",
  "publisher": "HL7 International / FHIR Infrastructure",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/fiwg"
        }
      ]
    }
  ],
  "description": "SearchParameter for Protective Factor Extension with Reference data type",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001"
        }
      ]
    }
  ],
  "code": "workflow-protectiveFactorRef",
  "base": [
    "CarePlan",
    "CommunicationRequest",
    "Goal"
  ],
  "type": "reference",
  "expression": "CarePlan.activity.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference |                      CommunicationRequest.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference |                      Goal.extension('http://hl7.org/fhir/StructureDefinition/workflow-protectiveFactor').value.reference",
  "processingMode": "normal"
}