FHIR © HL7.org  |  FHIRsmith 4.0.1  |  Server Home  |  XIG Home  |  XIG Stats  | 

FHIR IG analytics

Packagehl7.fhir.uv.dicom-sr
Resource TypeObservation
IdObservation-derived-imaging-measurement.json
FHIR VersionR5

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: Observation derived-imaging-measurement

basedOn: ServiceRequest: identifier = Accession ID: ACSN-235813; status = active; intent = order

partOf: ImagingStudy: identifier = urn:dicom:uid#DICOM Unique Id#urn:oid:1.2.840.113747.20080222.83311413144566317081790268995; status = available

status: Final

code: Peak Value Within ROI

subject: Anonymous Patient (no stated gender), DoB Unknown ( Medical Record Number: PID-12345)

effective: 2024-07-24 08:23:42+0000

issued: 2024-07-24 08:23:42+0000

performer: Practitioner EXAMPLE RADIOLOGIST

value: 123.45 Hounsfield unit (Details: UCUM code[hnsf'U] = '[hnsf'U]')

device: Device: identifier = urn:dicom:uid#DICOM Unique Id#1.2.840.113747.20080222.83311413144566317081790268995.8888; displayName = Example Imaging Measurement Device; manufacturer = Example Device Manufacturer

derivedFrom: Observation Radiographic measurement of lung volume


Source1

{
  "resourceType": "Observation",
  "id": "derived-imaging-measurement",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/uv/dicom-sr/StructureDefinition/derived-imaging-measurement"
    ]
  },
  "language": "en",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "basedOn": [
    {
      "reference": "ServiceRequest/measurement-report-service-request"
    }
  ],
  "partOf": [
    {
      "reference": "ImagingStudy/measurement-report-imaging-study"
    }
  ],
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://dicom.nema.org/resources/ontology/DCM",
        "code": "126031",
        "display": "Peak Value Within ROI"
      }
    ]
  },
  "subject": {
    "reference": "Patient/measurement-report-patient"
  },
  "effectiveDateTime": "2024-07-24T08:23:42+00:00",
  "issued": "2024-07-24T08:23:42+00:00",
  "performer": [
    {
      "reference": "Practitioner/measurement-report-practitioner"
    }
  ],
  "valueQuantity": {
    "value": 123.45,
    "unit": "Hounsfield unit",
    "system": "http://unitsofmeasure.org",
    "code": "[hnsf'U]"
  },
  "device": {
    "reference": "Device/measurement-report-general-equipment"
  },
  "derivedFrom": [
    {
      "reference": "Observation/imaging-measurement-group"
    }
  ]
}