| Package | hl7.fhir.uv.dicom-sr |
| Resource Type | ConceptMap |
| Id | dicom-document-ie-to-fhir |
| FHIR Version | R5 |
| Source | http://hl7.org/fhir/uv/dicom-sr/https://build.fhir.org/ig/HL7/dicom-sr/ConceptMap-dicom-document-ie-to-fhir.html |
| URL | http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir |
| Version | 1.0.0 |
| Status | active |
| Date | 2025-05-01T18:03:49+00:00 |
| Name | DICOMDocumentIEToFHIRMapping |
| Title | ConceptMap - DICOM Document IE to FHIR Mapping |
| Realm | uv |
| Authority | hl7 |
| Description | Mapping between DICOM® Document IE and FHIR Resources |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap dicom-document-ie-to-fhir
Mapping from DICOM-Document to Bundle
Group 1 Mapping from unspecified code system to unspecified code system
| Source Concept Details | Relationship | Target Concept Details | Comment | Properties | |||||
| Codes from | DICOMConceptNameCodeSequence | OverserverType | Codes from | macro-map | content-map | ||||
| DICOM.SR.Document.General | Document General Module | (not mapped) | |||||||
| DICOM.PreliminaryFlag | Preliminary Flag (0040,A496) | is equivalent to | status | status | DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'. | todo | todo | ||
| DICOM.ParticipantSequence-Performer | Participant Sequence (0040,A07A) -- PSN | PSN | is equivalent to | performer | performer | todo | todo | ||
| DICOM.ParticipantSequence-Device | Participant Sequence (0040,A07A) -- DEV | DEV | is equivalent to | Device[1] | Device[1] | If this device matches the Equipment IE device an additional device resource does not need to be created. | todo | todo | |
| DICOM.ContentSequence.ImagingMeasurements | Content Sequence (0040,A730) -- Imaging Measurements | is narrower than | Observation[1] | Observation[1] | todo | todo | |||
{
"resourceType": "ConceptMap",
"id": "dicom-document-ie-to-fhir",
"text": {
"status": "generated",
"div": "<!-- snip (see above) -->"
},
"extension": [
{
"url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
"valueCode": "ii"
}
],
"url": "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir",
"identifier": [
{
"system": "urn:ietf:rfc:3986",
"value": "urn:oid:2.16.840.1.113883.4.642.40.39.18.2"
}
],
"version": "1.0.0",
"name": "DICOMDocumentIEToFHIRMapping",
"title": "ConceptMap - DICOM Document IE to FHIR Mapping",
"status": "active",
"experimental": false,
"date": "2025-05-01T18:03:49+00:00",
"publisher": "HL7 International / Imaging Integration",
"contact": [
{
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name": "HL7 International / Imaging Integration",
"telecom": [
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name": "Jonathan Whitby",
"telecom": [
{
"system": "email",
"value": "jonathan.whitby@mi.medical.canon"
},
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
},
{
"name": "Christopher Lindop",
"telecom": [
{
"system": "email",
"value": "Christopher.Lindop@ge.com"
},
{
"system": "url",
"value": "http://www.hl7.org/Special/committees/imagemgt"
}
]
}
],
"description": "Mapping between DICOM® Document IE and FHIR Resources",
"jurisdiction": [
{
"coding": [
{
"system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
"code": "001"
}
]
}
],
"property": [
{
"code": "macro-map",
"type": "string"
},
{
"code": "content-map",
"type": "string"
}
],
"additionalAttribute": [
{
"code": "OverserverType",
"uri": "https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.2.4.html#table_C.17-3b",
"description": "DICOM.ParticipantSequence.ObserverType",
"type": "code"
},
{
"code": "DICOMConceptNameCodeSequence",
"uri": "https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.3.3.html#table_C.17-5",
"description": "DICOM Concept Name Code Sequence (0040,A043)",
"type": "Coding"
}
],
"sourceScopeUri": "DICOM-Document",
"targetScopeUri": "Bundle",
"group": [
{
"element": [
{
"code": "DICOM.SR.Document.General",
"display": "Document General Module",
"noMap": true
},
{
"code": "DICOM.PreliminaryFlag",
"display": "Preliminary Flag (0040,A496)",
"target": [
{
"code": "status",
"display": "status",
"relationship": "equivalent",
"comment": "DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'."
}
]
},
{
"code": "DICOM.ParticipantSequence-Performer",
"display": "Participant Sequence (0040,A07A) -- PSN",
"target": [
{
"code": "performer",
"display": "performer",
"relationship": "equivalent",
"property": [
{
"code": "macro-map",
"valueString": "identified-person-or-device"
}
],
"dependsOn": [
{
"attribute": "OverserverType",
"valueCode": "PSN"
}
]
}
]
},
{
"code": "DICOM.ParticipantSequence-Device",
"display": "Participant Sequence (0040,A07A) -- DEV",
"target": [
{
"code": "Device[1]",
"display": "Device[1]",
"relationship": "equivalent",
"comment": "If this device matches the Equipment IE device an additional device resource does not need to be created.",
"property": [
{
"code": "macro-map",
"valueString": "identified-person-or-device"
}
],
"dependsOn": [
{
"attribute": "OverserverType",
"valueCode": "DEV"
}
]
}
]
},
{
"code": "DICOM.ContentSequence.ImagingMeasurements",
"display": "Content Sequence (0040,A730) -- Imaging Measurements",
"target": [
{
"code": "Observation[1]",
"display": "Observation[1]",
"relationship": "source-is-narrower-than-target",
"property": [
{
"code": "content-map",
"valueString": "dicom-imaging-measurement-group"
}
],
"dependsOn": [
{
"attribute": "DICOMConceptNameCodeSequence",
"valueCoding": {
"system": "http://dicom.nema.org/resources/ontology/DCM",
"code": "126010",
"display": "Imaging Measurements"
}
}
]
}
]
}
]
}
]
}