Package | hl7.fhir.uv.dicom-sr |
Type | ConceptMap |
Id | dicom-document-ie-to-fhir |
FHIR Version | R5 |
Source | http://hl7.org/fhir/uv/dicom-sr/https://build.fhir.org/ig/HL7/dicom-sr/ConceptMap-dicom-document-ie-to-fhir.html |
URL | http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir |
Version | 1.0.0 |
Status | active |
Date | 2025-05-01T18:03:49+00:00 |
Name | DICOMDocumentIEToFHIRMapping |
Title | ConceptMap - DICOM Document IE to FHIR Mapping |
Realm | uv |
Authority | hl7 |
Description | Mapping between DICOM® Document IE and FHIR Resources |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap dicom-document-ie-to-fhir
Mapping from DICOM-Document to Bundle
Group 1 Mapping from unspecified code system
to unspecified code system
Source Concept Details | Relationship | Target Concept Details | Comment | Properties | |||||
Codes from | DICOMConceptNameCodeSequence | OverserverType | Codes from | macro-map | content-map | ||||
DICOM.SR.Document.General | Document General Module | (not mapped) | |||||||
DICOM.PreliminaryFlag | Preliminary Flag (0040,A496) | is equivalent to | status | status | DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'. | todo | todo | ||
DICOM.ParticipantSequence-Performer | Participant Sequence (0040,A07A) -- PSN | PSN | is equivalent to | performer | performer | todo | todo | ||
DICOM.ParticipantSequence-Device | Participant Sequence (0040,A07A) -- DEV | DEV | is equivalent to | Device[1] | Device[1] | If this device matches the Equipment IE device an additional device resource does not need to be created. | todo | todo | |
DICOM.ContentSequence.ImagingMeasurements | Content Sequence (0040,A730) -- Imaging Measurements | is narrower than | Observation[1] | Observation[1] | todo | todo |
{ "resourceType": "ConceptMap", "id": "dicom-document-ie-to-fhir", "text": { "status": "generated", "div": "<!-- snip (see above) -->" }, "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode": "ii" } ], "url": "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir", "identifier": [ { "system": "urn:ietf:rfc:3986", "value": "urn:oid:2.16.840.1.113883.4.642.40.39.18.2" } ], "version": "1.0.0", "name": "DICOMDocumentIEToFHIRMapping", "title": "ConceptMap - DICOM Document IE to FHIR Mapping", "status": "active", "experimental": false, "date": "2025-05-01T18:03:49+00:00", "publisher": "HL7 International / Imaging Integration", "contact": [ { "telecom": [ { "system": "url", "value": "http://www.hl7.org/Special/committees/imagemgt" } ] }, { "name": "HL7 International / Imaging Integration", "telecom": [ { "system": "url", "value": "http://www.hl7.org/Special/committees/imagemgt" } ] }, { "name": "Jonathan Whitby", "telecom": [ { "system": "email", "value": "jonathan.whitby@mi.medical.canon" }, { "system": "url", "value": "http://www.hl7.org/Special/committees/imagemgt" } ] }, { "name": "Christopher Lindop", "telecom": [ { "system": "email", "value": "Christopher.Lindop@ge.com" }, { "system": "url", "value": "http://www.hl7.org/Special/committees/imagemgt" } ] } ], "description": "Mapping between DICOM® Document IE and FHIR Resources", "jurisdiction": [ { "coding": [ { "system": "http://unstats.un.org/unsd/methods/m49/m49.htm", "code": "001" } ] } ], "property": [ { "code": "macro-map", "type": "string" }, { "code": "content-map", "type": "string" } ], "additionalAttribute": [ { "code": "OverserverType", "uri": "https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.2.4.html#table_C.17-3b", "description": "DICOM.ParticipantSequence.ObserverType", "type": "code" }, { "code": "DICOMConceptNameCodeSequence", "uri": "https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.3.3.html#table_C.17-5", "description": "DICOM Concept Name Code Sequence (0040,A043)", "type": "Coding" } ], "sourceScopeUri": "DICOM-Document", "targetScopeUri": "Bundle", "group": [ { "element": [ { "code": "DICOM.SR.Document.General", "display": "Document General Module", "noMap": true }, { "code": "DICOM.PreliminaryFlag", "display": "Preliminary Flag (0040,A496)", "target": [ { "code": "status", "display": "status", "relationship": "equivalent", "comment": "DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'." } ] }, { "code": "DICOM.ParticipantSequence-Performer", "display": "Participant Sequence (0040,A07A) -- PSN", "target": [ { "code": "performer", "display": "performer", "relationship": "equivalent", "property": [ { "code": "macro-map", "valueString": "identified-person-or-device" } ], "dependsOn": [ { "attribute": "OverserverType", "valueCode": "PSN" } ] } ] }, { "code": "DICOM.ParticipantSequence-Device", "display": "Participant Sequence (0040,A07A) -- DEV", "target": [ { "code": "Device[1]", "display": "Device[1]", "relationship": "equivalent", "comment": "If this device matches the Equipment IE device an additional device resource does not need to be created.", "property": [ { "code": "macro-map", "valueString": "identified-person-or-device" } ], "dependsOn": [ { "attribute": "OverserverType", "valueCode": "DEV" } ] } ] }, { "code": "DICOM.ContentSequence.ImagingMeasurements", "display": "Content Sequence (0040,A730) -- Imaging Measurements", "target": [ { "code": "Observation[1]", "display": "Observation[1]", "relationship": "source-is-narrower-than-target", "property": [ { "code": "content-map", "valueString": "dicom-imaging-measurement-group" } ], "dependsOn": [ { "attribute": "DICOMConceptNameCodeSequence", "valueCoding": { "system": "http://dicom.nema.org/resources/ontology/DCM", "code": "126010", "display": "Imaging Measurements" } } ] } ] } ] } ] }