FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: ConceptMap/dicom-document-ie-to-fhir

Packagehl7.fhir.uv.dicom-sr
TypeConceptMap
Iddicom-document-ie-to-fhir
FHIR VersionR5
Sourcehttp://hl7.org/fhir/uv/dicom-sr/https://build.fhir.org/ig/HL7/dicom-sr/ConceptMap-dicom-document-ie-to-fhir.html
URLhttp://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir
Version1.0.0
Statusactive
Date2025-05-01T18:03:49+00:00
NameDICOMDocumentIEToFHIRMapping
TitleConceptMap - DICOM Document IE to FHIR Mapping
Realmuv
Authorityhl7
DescriptionMapping between DICOM® Document IE and FHIR Resources

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ConceptMap dicom-document-ie-to-fhir

Mapping from DICOM-Document to Bundle


Group 1 Mapping from unspecified code system to unspecified code system

Source Concept DetailsRelationshipTarget Concept DetailsCommentProperties
Codes from DICOMConceptNameCodeSequenceOverserverTypeCodes from macro-mapcontent-map
DICOM.SR.Document.GeneralDocument General Module(not mapped)
DICOM.PreliminaryFlagPreliminary Flag (0040,A496)is equivalent tostatusstatusDICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'.todotodo
DICOM.ParticipantSequence-PerformerParticipant Sequence (0040,A07A) -- PSNPSNis equivalent toperformerperformertodotodo
DICOM.ParticipantSequence-DeviceParticipant Sequence (0040,A07A) -- DEVDEVis equivalent toDevice[1]Device[1]If this device matches the Equipment IE device an additional device resource does not need to be created.todotodo
DICOM.ContentSequence.ImagingMeasurementsContent Sequence (0040,A730) -- Imaging Measurementsis narrower thanObservation[1]Observation[1]todotodo

Source

{
  "resourceType": "ConceptMap",
  "id": "dicom-document-ie-to-fhir",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "ii"
    }
  ],
  "url": "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-document-ie-to-fhir",
  "identifier": [
    {
      "system": "urn:ietf:rfc:3986",
      "value": "urn:oid:2.16.840.1.113883.4.642.40.39.18.2"
    }
  ],
  "version": "1.0.0",
  "name": "DICOMDocumentIEToFHIRMapping",
  "title": "ConceptMap - DICOM Document IE to FHIR Mapping",
  "status": "active",
  "experimental": false,
  "date": "2025-05-01T18:03:49+00:00",
  "publisher": "HL7 International / Imaging Integration",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name": "HL7 International / Imaging Integration",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name": "Jonathan Whitby",
      "telecom": [
        {
          "system": "email",
          "value": "jonathan.whitby@mi.medical.canon"
        },
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name": "Christopher Lindop",
      "telecom": [
        {
          "system": "email",
          "value": "Christopher.Lindop@ge.com"
        },
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    }
  ],
  "description": "Mapping between DICOM® Document IE and FHIR Resources",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001"
        }
      ]
    }
  ],
  "property": [
    {
      "code": "macro-map",
      "type": "string"
    },
    {
      "code": "content-map",
      "type": "string"
    }
  ],
  "additionalAttribute": [
    {
      "code": "OverserverType",
      "uri": "https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.2.4.html#table_C.17-3b",
      "description": "DICOM.ParticipantSequence.ObserverType",
      "type": "code"
    },
    {
      "code": "DICOMConceptNameCodeSequence",
      "uri": "https://dicom.nema.org/medical/dicom/current/output/chtml/part03/sect_C.17.3.3.html#table_C.17-5",
      "description": "DICOM Concept Name Code Sequence (0040,A043)",
      "type": "Coding"
    }
  ],
  "sourceScopeUri": "DICOM-Document",
  "targetScopeUri": "Bundle",
  "group": [
    {
      "element": [
        {
          "code": "DICOM.SR.Document.General",
          "display": "Document General Module",
          "noMap": true
        },
        {
          "code": "DICOM.PreliminaryFlag",
          "display": "Preliminary Flag (0040,A496)",
          "target": [
            {
              "code": "status",
              "display": "status",
              "relationship": "equivalent",
              "comment": "DICOM® values shall be converted to lowercase. e.g. 'PRELIMINARY' to 'preliminary'."
            }
          ]
        },
        {
          "code": "DICOM.ParticipantSequence-Performer",
          "display": "Participant Sequence (0040,A07A) -- PSN",
          "target": [
            {
              "code": "performer",
              "display": "performer",
              "relationship": "equivalent",
              "property": [
                {
                  "code": "macro-map",
                  "valueString": "identified-person-or-device"
                }
              ],
              "dependsOn": [
                {
                  "attribute": "OverserverType",
                  "valueCode": "PSN"
                }
              ]
            }
          ]
        },
        {
          "code": "DICOM.ParticipantSequence-Device",
          "display": "Participant Sequence (0040,A07A) -- DEV",
          "target": [
            {
              "code": "Device[1]",
              "display": "Device[1]",
              "relationship": "equivalent",
              "comment": "If this device matches the Equipment IE device an additional device resource does not need to be created.",
              "property": [
                {
                  "code": "macro-map",
                  "valueString": "identified-person-or-device"
                }
              ],
              "dependsOn": [
                {
                  "attribute": "OverserverType",
                  "valueCode": "DEV"
                }
              ]
            }
          ]
        },
        {
          "code": "DICOM.ContentSequence.ImagingMeasurements",
          "display": "Content Sequence (0040,A730) -- Imaging Measurements",
          "target": [
            {
              "code": "Observation[1]",
              "display": "Observation[1]",
              "relationship": "source-is-narrower-than-target",
              "property": [
                {
                  "code": "content-map",
                  "valueString": "dicom-imaging-measurement-group"
                }
              ],
              "dependsOn": [
                {
                  "attribute": "DICOMConceptNameCodeSequence",
                  "valueCoding": {
                    "system": "http://dicom.nema.org/resources/ontology/DCM",
                    "code": "126010",
                    "display": "Imaging Measurements"
                  }
                }
              ]
            }
          ]
        }
      ]
    }
  ]
}