Package | hl7.fhir.uv.dicom-sr |
Type | ConceptMap |
Id | dicom-derived-imaging-measurement-to-fhir |
FHIR Version | R5 |
Source | http://hl7.org/fhir/uv/dicom-sr/https://build.fhir.org/ig/HL7/dicom-sr/ConceptMap-dicom-derived-imaging-measurement-to-fhir.html |
URL | http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-derived-imaging-measurement-to-fhir |
Version | 1.0.0 |
Status | active |
Date | 2025-05-01T18:03:49+00:00 |
Name | DICOMDerivedImagingMeasurementToFHIRMapping |
Title | ConceptMap - DICOM Derived Imaging Measurement to FHIR Mapping |
Realm | uv |
Authority | hl7 |
Description | Mapping between DICOMĀ® Derived Imaging Measurement and FHIR Resources |
No resources found
No resources found
Note: links and images are rebased to the (stated) source
Generated Narrative: ConceptMap dicom-derived-imaging-measurement-to-fhir
Mapping from DICOM-Imaging-Measurement to Observation
Group 1 Mapping from unspecified code system
to unspecified code system
Source Concept Details | Relationship | Target Concept Details | |||
Codes from | ValueType | Codes from | |||
CID7465 | Measurement Derived From Multiple ROI Measurements | is equivalent to | valueQuantity | DerivedImagingMeasurement.valueQuantity |
Group 2 Mapping from unspecified code system
to unspecified code system
Source Code | Relationship | Target Code | Comment |
TID4019 (Algorithm Identification) | is equivalent to | device (DerivedImagingMeasurement.device) | Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device. |
Group 3 Mapping from unspecified code system
to unspecified code system
Source Concept Details | Relationship | Target Concept Details | Comment | ||
Codes from | Codes from | ||||
125007 | Measurement Group | is equivalent to | ImagingMeasurementGroup | ImagingMeasurementGroup | Measurement Group children of a derived imaging measurement content item are mapped to new ImagingMeasurementGroup observations. |
is equivalent to | derivedFrom | DerivedImagingMeasurement.derivedFrom |
{ "resourceType": "ConceptMap", "id": "dicom-derived-imaging-measurement-to-fhir", "text": { "status": "generated", "div": "<!-- snip (see above) -->" }, "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode": "ii" } ], "url": "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-derived-imaging-measurement-to-fhir", "identifier": [ { "system": "urn:ietf:rfc:3986", "value": "urn:oid:2.16.840.1.113883.4.642.40.39.18.1" } ], "version": "1.0.0", "name": "DICOMDerivedImagingMeasurementToFHIRMapping", "title": "ConceptMap - DICOM Derived Imaging Measurement to FHIR Mapping", "status": "active", "experimental": false, "date": "2025-05-01T18:03:49+00:00", "publisher": "HL7 International / Imaging Integration", "contact": [ { "telecom": [ { "system": "url", "value": "http://www.hl7.org/Special/committees/imagemgt" } ] }, { "name": "HL7 International / Imaging Integration", "telecom": [ { "system": "url", "value": "http://www.hl7.org/Special/committees/imagemgt" } ] }, { "name": "Jonathan Whitby", "telecom": [ { "system": "email", "value": "jonathan.whitby@mi.medical.canon" }, { "system": "url", "value": "http://www.hl7.org/Special/committees/imagemgt" } ] }, { "name": "Christopher Lindop", "telecom": [ { "system": "email", "value": "Christopher.Lindop@ge.com" }, { "system": "url", "value": "http://www.hl7.org/Special/committees/imagemgt" } ] } ], "description": "Mapping between DICOMĀ® Derived Imaging Measurement and FHIR Resources", "jurisdiction": [ { "coding": [ { "system": "http://unstats.un.org/unsd/methods/m49/m49.htm", "code": "001" } ] } ], "additionalAttribute": [ { "code": "IdentifierType", "uri": "http://dicom.nema.org/resources/ontology/DCM", "description": "DICOM Controlled Terminology", "type": "Coding" }, { "code": "ValueType", "uri": "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type", "description": "DICOM Value Type", "type": "Coding" } ], "sourceScopeUri": "DICOM-Imaging-Measurement", "targetScopeUri": "Observation", "group": [ { "element": [ { "code": "CID7465", "display": "Measurement Derived From Multiple ROI Measurements", "target": [ { "code": "valueQuantity", "display": "DerivedImagingMeasurement.valueQuantity", "relationship": "equivalent", "dependsOn": [ { "attribute": "ValueType", "valueCoding": { "system": "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type", "code": "num" } } ] } ] } ] }, { "element": [ { "code": "TID4019", "display": "Algorithm Identification", "target": [ { "code": "device", "display": "DerivedImagingMeasurement.device", "relationship": "equivalent", "comment": "Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device." } ] } ] }, { "element": [ { "code": "125007", "display": "Measurement Group", "target": [ { "code": "ImagingMeasurementGroup", "display": "ImagingMeasurementGroup", "relationship": "equivalent", "comment": "Measurement Group children of a derived imaging measurement content item are mapped to new ImagingMeasurementGroup observations." }, { "code": "derivedFrom", "display": "DerivedImagingMeasurement.derivedFrom", "relationship": "equivalent" } ] } ] } ] }