DescriptionThis category applies only if an app exchanges data with other devices, health apps, and/or HIT systems. If so, there are applicable standards for data format, vocabulary, and transport, to increase interoperability and ease of connection.

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Statement N:

This category applies only if an app exchanges data with other devices, health apps, and/or HIT systems. If so, there are applicable standards for data format, vocabulary, and transport, to increase interoperability and ease of connection.

Criteria N:
APU.7#93 SHALL

[App exchanges discrete clinical data] Use standard terminologies (e.g., SNOMED CT, LOINC…).

APU.7#94 SHALL

[App exchanges discrete clinical data] Use standard format/content, e.g., HL7 FHIR, SMART on FHIR, HL7 Consolidated CDA, Detailed Clinical Models (HL7 CIMI), etc.

APU.7#95 SHOULD

[App exchanges discrete clinical data with devices] Use standard format/content, e.g., IEEE 11073.

APU.7#96 SHOULD

[App exchanges unstructured data] Use standard or commonly accepted formats, e.g., HL7 CDA, PDF.

APU.7#97 SHOULD

[App collects personal health information] allow data to be imported or exported from the app.[1]


Source

{
  "resourceType": "Requirements",
  "id": "CMHAFFR2-APU.7",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/uv/cmhaffr2/StructureDefinition/FMHeader"
    ]
  },
  "text": {
    "status": "extensions",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "mobile"
    }
  ],
  "url": "http://hl7.org/fhir/uv/cmhaffr2/Requirements/CMHAFFR2-APU.7",
  "version": "2.0.1",
  "name": "APU_7_Data_Exchange_and_Interoperability",
  "title": "APU.7 Data Exchange and Interoperability (Header)",
  "status": "active",
  "date": "2025-05-28T08:01:49+00:00",
  "publisher": "HL7 International / Mobile Health",
  "contact": [
    {
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/mobile"
        }
      ]
    }
  ],
  "description": "This category applies only if an app exchanges data with other devices, health apps, and/or HIT systems. If so, there are applicable\nstandards for data format, vocabulary, and transport, to increase interoperability and ease of connection.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "statement": [
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/uv/cmhaffr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "CMHAFFR2-APU.7-93",
      "label": "APU.7#93",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "[App exchanges discrete clinical data] Use standard terminologies (e.g., SNOMED CT, LOINC…)."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/uv/cmhaffr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "CMHAFFR2-APU.7-94",
      "label": "APU.7#94",
      "conformance": [
        "SHALL"
      ],
      "conditionality": false,
      "requirement": "[App exchanges discrete clinical data] Use standard format/content, e.g., HL7 FHIR, SMART on FHIR, HL7 Consolidated CDA, Detailed Clinical Models (HL7 CIMI), etc."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/uv/cmhaffr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "CMHAFFR2-APU.7-95",
      "label": "APU.7#95",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "[App exchanges discrete clinical data with devices] Use standard format/content, e.g., IEEE 11073."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/uv/cmhaffr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "CMHAFFR2-APU.7-96",
      "label": "APU.7#96",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "[App exchanges unstructured data] Use standard or commonly accepted formats, e.g., HL7 CDA, PDF."
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/uv/cmhaffr2/StructureDefinition/requirements-dependent",
          "valueBoolean": false
        }
      ],
      "key": "CMHAFFR2-APU.7-97",
      "label": "APU.7#97",
      "conformance": [
        "SHOULD"
      ],
      "conditionality": false,
      "requirement": "[App collects personal health information] allow data to be imported or exported from the app.[1]"
    }
  ]
}