FHIR © HL7.org  |  Server Home  |  XIG Home  |  Server Source  |  FHIR  

FHIR IG Statistics: ImplementationGuide/hl7.fhir.uv.cardx-cied

Packagehl7.fhir.uv.cardx-cied
TypeImplementationGuide
Idhl7.fhir.uv.cardx-cied
FHIR VersionR5
Sourcehttp://hl7.org/fhir/uv/cardx-cied/https://build.fhir.org/ig/HL7/CardX-CIED/index.html
URLhttp://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied
Version0.1.0
Statusdraft
Date2025-07-22T16:49:27+00:00
NameCardXCIED
TitleCardX - Cardiac Implantable Electronic Devices
Realmuv
Authorityhl7

Resources that use this resource

No resources found


Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: ImplementationGuide hl7.fhir.uv.cardx-cied

CardXCIED

The official URL for this implementation guide is:

http://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied

Source

{
  "resourceType": "ImplementationGuide",
  "id": "hl7.fhir.uv.cardx-cied",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "cic"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 2
    }
  ],
  "url": "http://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied",
  "version": "0.1.0",
  "name": "CardXCIED",
  "title": "CardX - Cardiac Implantable Electronic Devices",
  "status": "draft",
  "date": "2025-07-22T16:49:27+00:00",
  "publisher": "HL7 International / Clinical Interoperability Council",
  "contact": [
    {
      "name": "HL7 International / Clinical Interoperability Council",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/cic"
        },
        {
          "system": "email",
          "value": "ciclist@lists.hl7.org"
        }
      ]
    }
  ],
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "packageId": "hl7.fhir.uv.cardx-cied",
  "license": "CC0-1.0",
  "fhirVersion": [
    "5.0.0"
  ],
  "dependsOn": [
    {
      "id": "hl7tx",
      "extension": [
        {
          "url": "http://hl7.org/fhir/tools/StructureDefinition/implementationguide-dependency-comment",
          "valueMarkdown": "Automatically added as a dependency - all IGs depend on HL7 Terminology"
        }
      ],
      "uri": "http://terminology.hl7.org/ImplementationGuide/hl7.terminology",
      "packageId": "hl7.terminology.r5",
      "version": "6.5.0"
    },
    {
      "id": "hl7ext",
      "extension": [
        {
          "url": "http://hl7.org/fhir/tools/StructureDefinition/implementationguide-dependency-comment",
          "valueMarkdown": "Automatically added as a dependency - all IGs depend on the HL7 Extension Pack"
        }
      ],
      "uri": "http://hl7.org/fhir/extensions/ImplementationGuide/hl7.fhir.uv.extensions",
      "packageId": "hl7.fhir.uv.extensions.r5",
      "version": "5.2.0"
    }
  ],
  "definition": {
    "extension": [
      {
        "url": "http://hl7.org/fhir/tools/StructureDefinition/ig-internal-dependency",
        "valueCode": "hl7.fhir.uv.tools.r5#0.7.0"
      }
    ],
    "resource": [
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "CapabilityStatement"
          }
        ],
        "reference": {
          "reference": "CapabilityStatement/cied-data-sender"
        },
        "name": "CardX CIED Connectivity Server Capability Statement",
        "description": "This capability statement describes the requirements for systems that make CIED Connectivity data available.",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "ValueSet"
          }
        ],
        "reference": {
          "reference": "ValueSet/cied-connectivity-state-modifier-vs"
        },
        "name": "CIED Connectivity Status Modifier Value Set",
        "description": "Additional modifiers to connectivity status as calculated by the CIED manufacturer",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "ValueSet"
          }
        ],
        "reference": {
          "reference": "ValueSet/cied-connectivity-state-vs"
        },
        "name": "CIED Connectivity Status Value Set",
        "description": "The overall system connectivity status as calculated by the CIED manufacturer",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "CodeSystem"
          }
        ],
        "reference": {
          "reference": "CodeSystem/CIEDconnectivity"
        },
        "name": "CIED Connectivity Status Values",
        "description": "Codes system for CIED connectivity and monitor device types",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "StructureDefinition:extension"
          }
        ],
        "reference": {
          "reference": "StructureDefinition/cied-device-extension"
        },
        "name": "CIED Device Extension",
        "description": "Extension to represent cardiac implantable device(s) which generated the observation.",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "ValueSet"
          }
        ],
        "reference": {
          "reference": "ValueSet/cied-monitor-types-vs"
        },
        "name": "CIED Monitor Types",
        "description": "The type of CIED monitor",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "ValueSet"
          }
        ],
        "reference": {
          "reference": "ValueSet/cied-patient-identifier"
        },
        "name": "CIED Patient Identifier",
        "description": "Identifiers which can be used to identify CIED patients.",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "StructureDefinition:resource"
          }
        ],
        "reference": {
          "reference": "StructureDefinition/cied-device"
        },
        "name": "Device - Cardiovascular Implantable Electronic Device (CIED)",
        "description": "\nThe following data-elements must always be present (Mandatory definition) or must be supported if the data is present in the sending system (Must Support definition). They are presented below in a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Profile Definition below provides the formal summary, definitions, and terminology requirements.\n\nWithin IEEE 11073-10103, MDC_IDC_DEV contains the following data elements:\nMDC_IDC_DEV_TYPE\nMDC_IDC_DEV_MODEL\nMDC_IDC_DEV_SERIAL\nMDC_IDC_DEV_MFG",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "StructureDefinition:resource"
          }
        ],
        "reference": {
          "reference": "StructureDefinition/cied-monitor"
        },
        "name": "Device - CIED Monitor Profile",
        "description": "\nThe following data-elements must always be present (Mandatory definition) or must be supported if the data is present in the sending system (Must Support definition). They are presented below in a simple human-readable explanation. Profile specific guidance and examples are provided as well. The Formal Profile Definition below provides the formal summary, definitions, and terminology requirements.\n\nWithin IEEE 11073-10103, MDC_IDC_DEV contains the following data elements:\nMDC_IDC_DEV_TYPE\nMDC_IDC_DEV_MODEL\nMDC_IDC_DEV_SERIAL\nMDC_IDC_DEV_MFG",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "ValueSet"
          }
        ],
        "reference": {
          "reference": "ValueSet/11073-10103-DeviceType"
        },
        "name": "IEEE 11073-10103 Device Type",
        "description": "The type of device as defined by IEEE 11073-10103",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "ValueSet"
          }
        ],
        "reference": {
          "reference": "ValueSet/11073-10103-SessionType"
        },
        "name": "IEEE 11073-10103 Session Type",
        "description": "The type of session as defined by IEEE 11073-10103",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "CodeSystem"
          }
        ],
        "reference": {
          "reference": "CodeSystem/IDC"
        },
        "name": "ISO/IEEE-11073-10103",
        "description": "ISO/IEEE-11073-10103 - Implantable Device Cardiac nomenclature.",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "StructureDefinition:resource"
          }
        ],
        "reference": {
          "reference": "StructureDefinition/cied-connectivity-status"
        },
        "name": "Observation - CIED Connectivity",
        "description": "\nProfile of the observation resource to present the most recent connectivity status and associated information for a CIED/Monitor pair.\n\nCIEDs and monitors connect at regular intervals to exchange data ranging from every few minutes to every other week depending on the device/monitor configuration and manufacturer. The connectivity observation profile is a snapshot in time and is not intended to be used to query historical log information that may have been captured by the remote monitoring IoT platform. A single observation will be returned for every CIED/monitor pair.",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "StructureDefinition:resource"
          }
        ],
        "reference": {
          "reference": "StructureDefinition/cied-patient"
        },
        "name": "Patient - CIED Patient Profile",
        "description": "An CIED profile of the Patient resource.",
        "isExample": false
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc1ACMEICD"
        },
        "name": "uc1ACMEICD",
        "description": "An example CIED device for CIED connectivity example 1.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-device"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Patient"
          }
        ],
        "reference": {
          "reference": "Patient/uc1ACMEPatient"
        },
        "name": "uc1ACMEPatient",
        "description": "An example CIED patient for CIED connectivity example 1.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-patient"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Observation"
          }
        ],
        "reference": {
          "reference": "Observation/uc1ConnectivityACME"
        },
        "name": "uc1ConnectivityACME",
        "description": "An example CIED connectivity status for CIED connectivity example 1.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-connectivity-status"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc2ACMEPacemaker"
        },
        "name": "uc2ACMEPacemaker",
        "description": "An example CIED device for CIED connectivity example 2.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-device"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Patient"
          }
        ],
        "reference": {
          "reference": "Patient/uc2ACMEPatient"
        },
        "name": "uc2ACMEPatient",
        "description": "An example CIED patient for CIED connectivity example 2.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-patient"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc2CIEDMonitor"
        },
        "name": "uc2CIEDMonitor",
        "description": "An example CIED monitor for CIED connectivity example 2.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-monitor"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Observation"
          }
        ],
        "reference": {
          "reference": "Observation/uc2ConnectivityACME"
        },
        "name": "uc2ConnectivityACME",
        "description": "An example CIED connectivity status for CIED connectivity example 2.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-connectivity-status"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc3ACMEPacemaker"
        },
        "name": "uc3ACMEPacemaker",
        "description": "An example CIED device for CIED connectivity example 3.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-device"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Patient"
          }
        ],
        "reference": {
          "reference": "Patient/uc3ACMEPatient"
        },
        "name": "uc3ACMEPatient",
        "description": "An example CIED patient for CIED connectivity example 3.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-patient"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc3CIEDMonitor"
        },
        "name": "uc3CIEDMonitor",
        "description": "An example CIED monitor for CIED connectivity example 3.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-monitor"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Observation"
          }
        ],
        "reference": {
          "reference": "Observation/uc3ConnectivityACME"
        },
        "name": "uc3ConnectivityACME",
        "description": "An example CIED connectivity status for CIED connectivity example 3.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-connectivity-status"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc4ACMEPacemaker"
        },
        "name": "uc4ACMEPacemaker",
        "description": "An example CIED device for CIED connectivity example 4.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-device"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Patient"
          }
        ],
        "reference": {
          "reference": "Patient/uc4ACMEPatient"
        },
        "name": "uc4ACMEPatient",
        "description": "An example CIED patient for CIED connectivity example 4.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-patient"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc4CIEDMonitor"
        },
        "name": "uc4CIEDMonitor",
        "description": "An example CIED monitor for CIED connectivity example 4.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-monitor"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Observation"
          }
        ],
        "reference": {
          "reference": "Observation/uc4ConnectivityACME"
        },
        "name": "uc4ConnectivityACME",
        "description": "An example CIED connectivity status for CIED connectivity example 4.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-connectivity-status"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc5ACMEPacemaker"
        },
        "name": "uc5ACMEPacemaker",
        "description": "An example CIED device for CIED connectivity example 5.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-device"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Patient"
          }
        ],
        "reference": {
          "reference": "Patient/uc5ACMEPatient"
        },
        "name": "uc5ACMEPatient",
        "description": "An example CIED patient for CIED connectivity example 5.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-patient"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Device"
          }
        ],
        "reference": {
          "reference": "Device/uc5CIEDMonitor"
        },
        "name": "uc5CIEDMonitor",
        "description": "An example CIED monitor for CIED connectivity example 5.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-monitor"
        ]
      },
      {
        "extension": [
          {
            "url": "http://hl7.org/fhir/tools/StructureDefinition/resource-information",
            "valueString": "Observation"
          }
        ],
        "reference": {
          "reference": "Observation/uc5ConnectivityACME"
        },
        "name": "uc5ConnectivityACME",
        "description": "An example CIED connectivity status for CIED connectivity example 5.",
        "isExample": true,
        "profile": [
          "http://hl7.org/fhir/uv/cardx-cied/StructureDefinition/cied-connectivity-status"
        ]
      }
    ],
    "page": {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
          "valueCode": "informative"
        }
      ],
      "sourceUrl": "toc.html",
      "name": "toc.html",
      "title": "Table of Contents",
      "generation": "html",
      "page": [
        {
          "extension": [
            {
              "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
              "valueCode": "informative"
            }
          ],
          "sourceUrl": "index.html",
          "name": "index.html",
          "title": "Home",
          "generation": "markdown"
        },
        {
          "extension": [
            {
              "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
              "valueCode": "informative"
            }
          ],
          "sourceUrl": "Background.html",
          "name": "Background.html",
          "title": "Background",
          "generation": "markdown"
        },
        {
          "extension": [
            {
              "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
              "valueCode": "informative"
            }
          ],
          "sourceUrl": "connectivity-status.html",
          "name": "connectivity-status.html",
          "title": "Connectivity Status",
          "generation": "markdown"
        },
        {
          "extension": [
            {
              "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
              "valueCode": "informative"
            }
          ],
          "sourceUrl": "user-stories.html",
          "name": "user-stories.html",
          "title": "User Stories",
          "generation": "markdown"
        }
      ]
    },
    "parameter": [
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "copyrightyear"
        },
        "value": "2025+"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "releaselabel"
        },
        "value": "ci-build"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "apply-contact"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "apply-jurisdiction"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "apply-publisher"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "apply-version"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "path-history"
        },
        "value": "http://hl7.org/fhir/uv/cardx-cied/history.html"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "autoload-resources"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/capabilities"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/examples"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/extensions"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/models"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/operations"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/profiles"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/resources"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/vocabulary"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/maps"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/testing"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "input/history"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-resource"
        },
        "value": "fsh-generated/resources"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-pages"
        },
        "value": "template/config"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-pages"
        },
        "value": "input/images"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "path-liquid"
        },
        "value": "template/liquid"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "path-liquid"
        },
        "value": "input/liquid"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "path-qa"
        },
        "value": "temp/qa"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "path-temp"
        },
        "value": "temp/pages"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "path-output"
        },
        "value": "output"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/guide-parameter-code",
          "code": "path-tx-cache"
        },
        "value": "input-cache/txcache"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "path-suppressed-warnings"
        },
        "value": "input/ignoreWarnings.txt"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "template-html"
        },
        "value": "template-page.html"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "template-md"
        },
        "value": "template-page-md.html"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "apply-context"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "apply-copyright"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "apply-license"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "apply-wg"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "active-tables"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "fmm-definition"
        },
        "value": "http://hl7.org/fhir/versions.html#maturity"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "propagate-status"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "excludelogbinaryformat"
        },
        "value": "true"
      },
      {
        "code": {
          "system": "http://hl7.org/fhir/tools/CodeSystem/ig-parameters",
          "code": "tabbed-snapshots"
        },
        "value": "true"
      }
    ]
  }
}