FHIR IG Statistics: CodeSystem/IDC

Packagehl7.fhir.uv.cardx-cied
Resource TypeCodeSystem
IdIDC
FHIR VersionR5
Sourcehttp://hl7.org/fhir/uv/cardx-cied/https://build.fhir.org/ig/HL7/CardX-CIED/CodeSystem-IDC.html
URLhttp://hl7.org/fhir/uv/cardx-cied/CodeSystem/IDC
Version1.0.0
Statusactive
Date2025-07-25T16:42:57+00:00
NameIDC
TitleISO/IEEE-11073-10103
Realmuv
Authorityhl7
DescriptionISO/IEEE-11073-10103 - Implantable Device Cardiac nomenclature.
Contentcomplete

Resources that use this resource

ValueSet
11073-10103-DeviceTypeIEEE 11073-10103 Device Type
11073-10103-SessionTypeIEEE 11073-10103 Session Type
cied-patient-identifierCIED Patient Identifier

Resources that this resource uses

No resources found


Narrative

Note: links and images are rebased to the (stated) source

Generated Narrative: CodeSystem IDC

This case-sensitive code system http://hl7.org/fhir/uv/cardx-cied/CodeSystem/IDC defines the following codes:

CodeDisplayDefinition
753665 PacemakerA battery powered implantable device that uses low voltage pulses to stimulate the heart when it is beating too slow.
753666 DefibrillatorA battery powered implantable device that uses high voltage energy to shock the heart when it is beating too fast and mostly includes pacemaker functionality.
753667 Cardiac Resynchronization Therapy - DefibrillatorA battery powered implantable device that uses low voltage pulses to stimulate the ventricles of the heart in multiple locations to increase blood pumping efficiency and also includes pacemaker and defibrillator functionality.
753668 Cardiac Resynchronization Therapy - PacemakerA battery powered implantable device that uses low voltage pulses to stimulate the ventricles of the heart in multiple locations to increase blood pumping efficiency and also includes pacemaker functionality.
753669 Implantable Diagnostic MonitorA battery powered implantable device that monitors and records cardiac activity and does not deliver any therapy.
753670 OtherA device type other than those included in the nomenclature.
754049 ImplantAn indicator that the data was acquired at the time of the surgical implant.
754050 In ClinicAn indicator that the data was acquired when the patient was in a hospital or clinic.
754051 RemoteAn indicator that the data was acquired while the patient was outside a hospital or clinic.
754052 Remote Device InitiatedAn indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and because of a condition the device detected.
754053 Remote ScheduledAn indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and at a time that was planned in advance.
754054 Remote Patient InitiatedAn indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and because of an action by the patient at a time that was not planned in advance.
754055 OtherAn interrogation session type not currently defined within the nomenclature.
754056 UnknownAn indicator showing that the session type is unknown for the interrogation session.
idco-pid Identifier used in IDCO PID HL7 SegmentIDCO specifies a combination of model and serial number as model:model-number/serial:serial-number

Source

{
  "resourceType": "CodeSystem",
  "id": "IDC",
  "text": {
    "status": "generated",
    "div": "<!-- snip (see above) -->"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode": "cic"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
      "valueInteger": 2,
      "_valueInteger": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied"
          }
        ]
      }
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
      "valueCode": "trial-use",
      "_valueCode": {
        "extension": [
          {
            "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom",
            "valueCanonical": "http://hl7.org/fhir/uv/cardx-cied/ImplementationGuide/hl7.fhir.uv.cardx-cied"
          }
        ]
      }
    }
  ],
  "url": "http://hl7.org/fhir/uv/cardx-cied/CodeSystem/IDC",
  "version": "1.0.0",
  "name": "IDC",
  "title": "ISO/IEEE-11073-10103",
  "status": "active",
  "experimental": false,
  "date": "2025-07-25T16:42:57+00:00",
  "publisher": "HL7 International / Clinical Interoperability Council",
  "contact": [
    {
      "name": "HL7 International / Clinical Interoperability Council",
      "telecom": [
        {
          "system": "url",
          "value": "http://www.hl7.org/Special/committees/cic"
        },
        {
          "system": "email",
          "value": "ciclist@lists.hl7.org"
        }
      ]
    }
  ],
  "description": "ISO/IEEE-11073-10103 - Implantable Device Cardiac nomenclature.",
  "jurisdiction": [
    {
      "coding": [
        {
          "system": "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code": "001",
          "display": "World"
        }
      ]
    }
  ],
  "caseSensitive": true,
  "content": "complete",
  "count": 15,
  "concept": [
    {
      "code": "753665",
      "display": "Pacemaker",
      "definition": "A battery powered implantable device that uses low voltage pulses to stimulate the heart when it is beating too slow."
    },
    {
      "code": "753666",
      "display": "Defibrillator",
      "definition": "A battery powered implantable device that uses high voltage energy to shock the heart when it is beating too fast and mostly includes pacemaker functionality."
    },
    {
      "code": "753667",
      "display": "Cardiac Resynchronization Therapy - Defibrillator",
      "definition": "A battery powered implantable device that uses low voltage pulses to stimulate the ventricles of the heart in multiple locations to increase blood pumping efficiency and also includes pacemaker and defibrillator functionality."
    },
    {
      "code": "753668",
      "display": "Cardiac Resynchronization Therapy - Pacemaker",
      "definition": "A battery powered implantable device that uses low voltage pulses to stimulate the ventricles of the heart in multiple locations to increase blood pumping efficiency and also includes pacemaker functionality."
    },
    {
      "code": "753669",
      "display": "Implantable Diagnostic Monitor",
      "definition": "A battery powered implantable device that monitors and records cardiac activity and does not deliver any therapy."
    },
    {
      "code": "753670",
      "display": "Other",
      "definition": "A device type other than those included in the nomenclature."
    },
    {
      "code": "754049",
      "display": "Implant",
      "definition": "An indicator that the data was acquired at the time of the surgical implant."
    },
    {
      "code": "754050",
      "display": "In Clinic",
      "definition": "An indicator that the data was acquired when the patient was in a hospital or clinic."
    },
    {
      "code": "754051",
      "display": "Remote",
      "definition": "An indicator that the data was acquired while the patient was outside a hospital or clinic."
    },
    {
      "code": "754052",
      "display": "Remote Device Initiated",
      "definition": "An indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and because of a condition the device detected."
    },
    {
      "code": "754053",
      "display": "Remote Scheduled",
      "definition": "An indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and at a time that was planned in advance."
    },
    {
      "code": "754054",
      "display": "Remote Patient Initiated",
      "definition": "An indicator that the data was acquired while the patient was outside a hospital or clinic using transmission equipment and because of an action by the patient at a time that was not planned in advance."
    },
    {
      "code": "754055",
      "display": "Other",
      "definition": "An interrogation session type not currently defined within the nomenclature."
    },
    {
      "code": "754056",
      "display": "Unknown",
      "definition": "An indicator showing that the session type is unknown for the interrogation session."
    },
    {
      "code": "idco-pid",
      "display": "Identifier used in IDCO PID HL7 Segment",
      "definition": "IDCO specifies a combination of model and serial number as model:model-number/serial:serial-number"
    }
  ]
}